Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizations

被引:60
|
作者
Schultz, FW
Geleijns, J
Spoelstra, FM
Zoetelief, J
机构
[1] Delft Univ Technol, Interfac Reactor Inst, NL-2629 JB Delft, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
来源
BRITISH JOURNAL OF RADIOLOGY | 2003年 / 76卷 / 909期
关键词
D O I
10.1259/bjr/21647806
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Effective dose is an important quantity in relation to assessment of radiation risk. Organ and effective doses to paediatric patients undergoing diagnostic and therapeutic heart catheterization procedures can be assessed by combining relatively simple measurements, e.g. of dose-area product (DAP), and calculated dose conversion factors (DCF). This also holds for the radiation dose to the hospital staff, e.g. the cardiologist. Monte Carlo (MC) simulation of radiation transport in mathematical anthropomorphic phantoms is used to obtain the DCFs, which strongly depend on beam quality and geometrical parameters. The performance of a dedicated fast MC code (PCXMC) for patient dosimetry is compared with that of a more elaborate general purpose MC code (MCNP). Resulting organ doses sometimes may differ considerably, partly due to phantom differences. While MCNP uses separate male and female mathematical phantoms, PCXMC uses a hermaphrodite. However, both codes yield effective doses that agree rather well, so PCXMC can be used for convenience. The MCNP code is used to calculate the effective dose to the cardiologist exposed to radiation scattered from the patient. Without protective clothing, effective dose per procedure to the cardiologist is at least two orders of magnitude lower than that to the patient. The effectiveness of various types and thickness of protective clothing has been evaluated for one view of one cardiac catheterization. The results of the calculations do not contradict experimental studies from the literature. MC simulation may serve as a useful tool to improve the accuracy of estimating occupational effective dose from personal dose monitors.
引用
收藏
页码:638 / 647
页数:10
相关论文
共 50 条
  • [1] Reducing Radiation Exposure in Cardiac Catheterizations for Congenital Heart Disease
    Patel, Chandni
    Grossman, Matthew
    Shabanova, Veronika
    Asnes, Jeremy
    PEDIATRIC CARDIOLOGY, 2019, 40 (03) : 638 - 649
  • [2] Reducing Radiation Exposure in Cardiac Catheterizations for Congenital Heart Disease
    Chandni Patel
    Matthew Grossman
    Veronika Shabanova
    Jeremy Asnes
    Pediatric Cardiology, 2019, 40 : 638 - 649
  • [3] Monte Carlo for radiation therapy dose calculations
    Siebers, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1303 - 1303
  • [4] Estimation of radiation dose and risk to children undergoing cardiac catheterization for the treatment of a congenital heart disease using Monte Carlo simulations
    Emmanuel Yakoumakis
    Helen Kostopoulou
    Triantafilia Makri
    Anastastios Dimitriadis
    Evaggelos Georgiou
    Ioannis Tsalafoutas
    Pediatric Radiology, 2013, 43 : 339 - 346
  • [5] Estimation of radiation dose and risk to children undergoing cardiac catheterization for the treatment of a congenital heart disease using Monte Carlo simulations
    Yakoumakis, Emmanuel
    Kostopoulou, Helen
    Makri, Triantafilia
    Dimitriadis, Anastastios
    Georgiou, Evaggelos
    Tsalafoutas, Ioannis
    PEDIATRIC RADIOLOGY, 2013, 43 (03) : 339 - 346
  • [6] Radiation Dose Reduction in Congenital Heart Disease Patients During Cardiac Catheterization by a Novel Protocol
    Gokalp, Selman
    Tanidir, Ibrahim Cansaran
    Ozturk, Erkut
    Ergul, Yakup
    Guzeltas, Alper
    TURKISH ARCHIVES OF PEDIATRICS, 2021, 56 (04): : 332 - 338
  • [7] REDUCING RADIATION EXPOSURE SAFELY DURING CARDIAC CATHETERIZATIONS WITH LOWER DOSE FLUOROSCOPY
    Chan, Albert K.
    Mehra, Ankit
    Aggarwal, Kul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1869 - E1869
  • [8] Monte Carlo Calculations of Dose Distribution in NSCLC Patients Planned for Stereotactic Body Radiation Therapy
    Moiseenko, V.
    Popescu, I. A.
    Liu, M.
    Kristensen, S.
    Gill, B.
    Teke, T.
    Bergman, A.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [9] A SET OF PATIENT AND STAFF DOSE DATA FOR VALIDATION OF MONTE CARLO CALCULATIONS IN INTERVENTIONAL CARDIOLOGY
    Vano, E.
    Sanchez, R. M.
    Fernandez, J. M.
    Bartal, G.
    Canevaro, L.
    Lykawka, R.
    Melo, C.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 235 - 239
  • [10] Monte Carlo Basics for Radiation Dose Assessment in Diagnostic Radiology
    Boone, John M.
    McNitt-Gray, Michael F.
    Hernandez, Andrew M.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (06) : 793 - 794