Nano nickel oxide modified non-enzymatic glucose sensors with enhanced sensitivity through an electrochemical process strategy at high potential

被引:442
|
作者
Mu, Ying [1 ]
Jia, Dongling [1 ]
He, Yayun [1 ]
Miao, Yuqing [1 ,2 ]
Wu, Hai-Long [2 ]
机构
[1] Zhejiang Normal Univ, Inst Phys Chem, Lab Biomimet Electrochem & Biosensors, Jinhua 321004, Peoples R China
[2] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 06期
基金
中国国家自然科学基金;
关键词
NiO; Non-enzymatic; Glucose sensors; Amperometric sensors; Ni(OH)(2); NiOOH; AMPEROMETRIC BIOSENSOR; GOLD NANOPARTICLES; ELECTRODE; ARRAY; WATER; FABRICATION; ADSORPTION; SURFACE; SERUM; FILM;
D O I
10.1016/j.bios.2010.11.042
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Development of fast and sensitive sensors for glucose determination is important in food industry, clinic diagnostics, biotechnology and many other areas. In these years, considerable attention has been paid to develop non-enzymatic electrodes to solve the disadvantages of the enzyme-modified electrodes, such as instability, high cost, complicated immobilization procedure and critical operating situation et al. Nano nickel oxide (NiO) modified non-enzymatic glucose sensors with enhanced sensitivity were investigated. Potential scanning nano NiO modified carbon paste electrodes up to high potential in alkaline solution greatly increases the amount of redox couple Ni(OH)(2)/NiOOH derived from NiO, and thus improves their electrochemical properties and electrocatalytical performance toward the oxidation of glucose. The nonenzymatic sensors response quickly to glucose and the response time is less than 5 s, demonstrating excellent electrocatalytical activity and assay performance. The calibration plot is linear over the wide concentration range of 1-110 mu M with a sensitivity of 43.9 nAh/mu M and a correlation coefficient of 0.998. The detection limit of the electrode was found to be 0.16 mu M at a signal-to-noise ratio of 3. The proposed non-enzymatic sensors can be used for the assay of glucose in real sample. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2948 / 2952
页数:5
相关论文
共 50 条
  • [21] Copper-nickel oxide nanofilm modified electrode for non-enzymatic determination of glucose
    Hasanzadeh, Mahsa
    Hasanzadeh, Zahra
    Alizadeh, Sakineh
    Sayadi, Mehran
    Nezhad, Mojtaba Nasiri
    Sabzi, Reza E.
    Ahmadi, Sajjad
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2020, 10 (03): : 245 - 255
  • [22] Cobalt oxide acicular nanorods with high sensitivity for the non-enzymatic detection of glucose
    Kung, Chung-Wei
    Lin, Chia-Yu
    Lai, Yi-Hsuan
    Vittal, R.
    Ho, Kuo-Chuan
    BIOSENSORS & BIOELECTRONICS, 2011, 27 (01): : 125 - 131
  • [23] Electrochemical sensors based on modified track-etched membrane for non-enzymatic glucose determination
    Shakayeva, Aigerim Kh.
    Munasbaeva, Karlygash K.
    Zhumazhanova, Ainash T.
    Zdorovets, Maxim, V
    Korolkov, Ilya, V
    MICROCHEMICAL JOURNAL, 2023, 193
  • [24] Research progress of electrode materials for non-enzymatic glucose electrochemical sensors
    Liu, Jianjun
    Shen, Jijun
    Ji, Shengchao
    Zhang, Qingyang
    Zhao, Wei
    SENSORS & DIAGNOSTICS, 2023, 2 (01): : 36 - 45
  • [25] Carbon-supported nickel/nickel oxide nanohybrid composite as a high-performance sensor for electrochemical non-enzymatic glucose detection
    Ramu, Jagadish
    Ramasundaram, Subramaniyan
    Yellappa, Shivaraj
    Gunamalai, Lavanya
    Kamilya, Tapas
    Afzal, Mohd
    Jeffery, A. Anto
    Oh, Tae Hwan
    Mahanthappa, Mallappa
    Vishwanath, R. S.
    NEW JOURNAL OF CHEMISTRY, 2024, 48 (31) : 13814 - 13824
  • [26] Bismuth-Nanocomposites Modified SPCEs for Non-Enzymatic Electrochemical Sensors
    Madagalam, Mallikarjun
    Bartoli, Mattia
    Tagliaferro, Alberto
    Carrara, Sandro
    IEEE SENSORS JOURNAL, 2021, 21 (09) : 11155 - 11162
  • [27] Trends on the Development of Non-Enzymatic Electrochemical Sensors Modified with Metal-Organic Frameworks for the Quantification of Glucose
    Rebolledo-Perales, L. E.
    Hernandez, P.
    Alvarez-Romero, G. A.
    Hernandez-Ramirez, D.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (08)
  • [28] Enzymatic and non-enzymatic electrochemical glucose sensor based on carbon nano-onions
    Mohapatra, Jeotikanta
    Ananthoju, Balakrishna
    Nair, Vishnu
    Mitra, Arijit
    Bahadur, D.
    Medhekar, N. V.
    Aslam, M.
    APPLIED SURFACE SCIENCE, 2018, 442 : 332 - 341
  • [29] Metal oxide-based composite for non-enzymatic glucose sensors
    Liu, Shilin
    Zeng, Wen
    Guo, Qi
    Li, Yanqiong
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2020, 31 (19) : 16111 - 16136
  • [30] Green synthesis of reduced graphene oxide (rGO) and its applications in non-enzymatic electrochemical glucose sensors
    Gijare, Medha S.
    Chaudhari, Sharmila R.
    Ekar, Satish
    Shaikh, Shoyebmohamad F.
    Al-Enizi, Abdullah M.
    Pandit, Bidhan
    Garje, Anil D.
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2024, 450