Nano nickel oxide modified non-enzymatic glucose sensors with enhanced sensitivity through an electrochemical process strategy at high potential

被引:442
|
作者
Mu, Ying [1 ]
Jia, Dongling [1 ]
He, Yayun [1 ]
Miao, Yuqing [1 ,2 ]
Wu, Hai-Long [2 ]
机构
[1] Zhejiang Normal Univ, Inst Phys Chem, Lab Biomimet Electrochem & Biosensors, Jinhua 321004, Peoples R China
[2] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 06期
基金
中国国家自然科学基金;
关键词
NiO; Non-enzymatic; Glucose sensors; Amperometric sensors; Ni(OH)(2); NiOOH; AMPEROMETRIC BIOSENSOR; GOLD NANOPARTICLES; ELECTRODE; ARRAY; WATER; FABRICATION; ADSORPTION; SURFACE; SERUM; FILM;
D O I
10.1016/j.bios.2010.11.042
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Development of fast and sensitive sensors for glucose determination is important in food industry, clinic diagnostics, biotechnology and many other areas. In these years, considerable attention has been paid to develop non-enzymatic electrodes to solve the disadvantages of the enzyme-modified electrodes, such as instability, high cost, complicated immobilization procedure and critical operating situation et al. Nano nickel oxide (NiO) modified non-enzymatic glucose sensors with enhanced sensitivity were investigated. Potential scanning nano NiO modified carbon paste electrodes up to high potential in alkaline solution greatly increases the amount of redox couple Ni(OH)(2)/NiOOH derived from NiO, and thus improves their electrochemical properties and electrocatalytical performance toward the oxidation of glucose. The nonenzymatic sensors response quickly to glucose and the response time is less than 5 s, demonstrating excellent electrocatalytical activity and assay performance. The calibration plot is linear over the wide concentration range of 1-110 mu M with a sensitivity of 43.9 nAh/mu M and a correlation coefficient of 0.998. The detection limit of the electrode was found to be 0.16 mu M at a signal-to-noise ratio of 3. The proposed non-enzymatic sensors can be used for the assay of glucose in real sample. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2948 / 2952
页数:5
相关论文
共 50 条
  • [11] Hydrothermally Synthesized Nickel Oxide Nanosheets for Non-Enzymatic Electrochemical Glucose Detection
    Ahmad, Rafiq
    Khan, Marya
    Tripathy, Nirmalya
    Khan, M. Iqbal R.
    Khosla, Ajit
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (10)
  • [12] Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
    Toghill, Kathryn E.
    Compton, Richard G.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (09): : 1246 - 1301
  • [13] Electrode surface roughness greatly enhances the sensitivity of electrochemical non-enzymatic glucose sensors
    Zhang, Jing
    Kuang, Zhujun
    Li, Hui
    Li, Shaoguang
    Xia, Fan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 919
  • [14] Current advancements and prospects of enzymatic and non-enzymatic electrochemical glucose sensors
    Govindaraj, Muthukumar
    Srivastava, Ananya
    Muthukumaran, Magesh Kumar
    Tsai, Pei-Chien
    Lin, Yuan-Chung
    Raja, Bharathi Kannan
    Rajendran, Jerome
    Ponnusamy, Vinoth Kumar
    Selvi, J. Arockia
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2023, 253
  • [15] Non-Enzymatic Glucose Sensors Composed of Polyaniline Nanofibers with High Electrochemical Performance
    Sobahi, Nebras
    Alam, Md. Mottahir
    Imran, Mohd
    Khan, Mohammad Ehtisham
    Mohammad, Akbar
    Yoon, Taeho
    Mehedi, Ibrahim M.
    Hussain, Mohammad A.
    Abdulaal, Mohammed J.
    Jiman, Ahmad A.
    MOLECULES, 2024, 29 (11):
  • [16] Synthesis of Laser-Induced Cobalt Oxide for Non-Enzymatic Electrochemical Glucose Sensors
    Kang, Seung-Jo
    Pak, James Jungho
    CHEMELECTROCHEM, 2022, 9 (16)
  • [17] Electrochemical non-enzymatic glucose sensors: recent progress and perspectives
    Wei, Ming
    Qiao, Yanxia
    Zhao, Haitao
    Liang, Jie
    Li, Tingshuai
    Luo, Yonglan
    Lu, Siyu
    Shi, Xifeng
    Lu, Wenbo
    Sun, Xuping
    CHEMICAL COMMUNICATIONS, 2020, 56 (93) : 14553 - 14569
  • [18] Electrochemical non-enzymatic glucose sensors based on CuO nanostructures
    Yang, Jiahao
    Yin, Jing
    Xu, Lan
    JOURNAL OF ALLOYS AND COMPOUNDS, 2025, 1010
  • [19] Recent advances in electrochemical non-enzymatic glucose sensors - A review
    Hwang, Dae-Woong
    Lee, Saram
    Seo, Minjee
    Chung, Taek Dong
    ANALYTICA CHIMICA ACTA, 2018, 1033 : 1 - 34
  • [20] Non-Enzymatic Glucose Sensors Involving Copper: An Electrochemical Perspective
    Aun, Tan Tiek
    Salleh, Noordini Mohamad
    Ali, Umi Fazara Md
    Manan, Ninie Suhana Abdul
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2023, 53 (03) : 537 - 593