Four-dimensional computed tomography: Image formation and clinical protocol

被引:338
|
作者
Rietzel, E [1 ]
Pan, TS
Chen, GTY
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Gesell Schwerionenforsch mbH, Biophys Abt, Darmstadt, Germany
[3] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
4D computed tomography; 4D imagine; time resolved imaging;
D O I
10.1118/1.1869852
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion can introduce significant errors in radiotherapy. Conventional CT scans as commonly used for treatment planning can include severe motion artifacts that result from interplay effects between the advancing scan plane and object motion. To explicitly include organ/target motion in treatment planning and delivery, time-resolved CT data acquisition (4D Computed Tomography) is needed. 4DCT can be accomplished by oversampled CT data acquisition at each slice. During several CT tube rotations projection data are collected in axial cine mode for the duration of the patient's respiratory cycle (plus the time needed for a full CT gantry rotation). Multiple images are then reconstructed per slice that are evenly distributed over the acquisition time. Each of these images represents a different anatomical state during a respiratory cycle. After data acquisition at one couch position is completed, x rays are turned off and the couch advances to begin data acquisition again until full coverage of the scan length has been obtained. Concurrent to CT data acquisition the patient's abdominal surface motion is recorded in precise temporal correlation. To obtain CT volumes at different respiratory states, reconstructed images are sorted into different spatio-temporally coherent volumes based on respiratory phase as obtained from the patient's surface motion. During binning, phase tolerances are chosen to obtain complete volumetric information since images at different couch positions are reconstructed at different respiratory phases. We describe 4DCT image formation and associated experiments that characterize the properties of 4DCT. Residual motion artifacts remain due to partial projection effects. Temporal coherence within resorted 4DCT volumes is dominated by the number of reconstructed images per slice. The more images are reconstructed, the smaller phase tolerances can be for retrospective sorting. From phantom studies a precision of about 2.5 mm. for quasiregular motion and typical respiratory periods could be concluded. A protocol for 4DCT scanning was evaluated and clinically implemented at the MGH. Patient data are presented to elucidate how additional patient specific parameters can impact 4DCT imaging. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:874 / 889
页数:16
相关论文
共 50 条
  • [1] Commissioning a four-dimensional computed tomography system for clinical implementation
    Sasaki, D. K.
    Ingleby, H.
    Venkataraman, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4319 - 4320
  • [2] Quantitative assessment of four-dimensional computed tomography image acquisition quality
    Starkschall, George
    Desai, Neil
    Balter, Peter
    Prado, Karl
    Luo, Dershan
    Cody, Dianna
    Pan, Tinsu
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (03): : 1 - 20
  • [3] Exploring correlation information for image compression of four-dimensional computed tomography
    Yan, Hui
    Li, Yexiong
    Dai, Jianrong
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (07) : 1270 - 1277
  • [4] FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY: CLINICAL IMPACT FOR PATIENTS WITH PRIMARY HYPERPARATHYROIDISM
    Tian, Y.
    Tanny, S.
    Einsiedel, P.
    Lichtenstein, M.
    Stella, D.
    Phal, P.
    Miller, J.
    [J]. INTERNAL MEDICINE JOURNAL, 2017, 47 : 22 - 23
  • [5] Four-Dimensional Computed Tomography: Clinical Impact for Patients with Primary Hyperparathyroidism
    Tian, Yuan
    Tanny, Sharman Tan
    Einsiedel, Paul
    Lichtenstein, Meir
    Stella, Damien L.
    Phal, Pramit M.
    Miller, Julie A.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2018, 25 (01) : 117 - 121
  • [6] Four-Dimensional Computed Tomography: Clinical Impact for Patients with Primary Hyperparathyroidism
    Yuan Tian
    Sharman Tan Tanny
    Paul Einsiedel
    Meir Lichtenstein
    Damien L. Stella
    Pramit M. Phal
    Julie A. Miller
    [J]. Annals of Surgical Oncology, 2018, 25 : 117 - 121
  • [7] Quantitation of the four-dimensional computed tomography process
    Lu, W
    Parikh, P
    El Naqa, I
    Nystrom, M
    Hubenschmidt, J
    Wahab, S
    Singh, A
    Christensen, G
    Mutic, S
    Bradley, J
    Low, D
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1780 - 1780
  • [8] Quantitation of the four-dimensional computed tomography process
    Lu, W
    Parikh, P
    ElNaqa, I
    Nystrom, M
    Hubenschmidt, J
    Wahab, S
    Mutic, S
    Singh, A
    Christensen, G
    Bradley, JD
    Low, DA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S286 - S286
  • [9] Four-dimensional computed tomography: musculoskeletal applications
    Wong, Murray T.
    Wiens, Charmaine
    Kuczynski, Michael
    Manske, Sarah
    Schneider, Prism S.
    [J]. CANADIAN JOURNAL OF SURGERY, 2022, 65 (03) : E388 - E393
  • [10] Effect of respiratory cycle irregularities on image quality in four-dimensional computed tomography
    Thorndyke, B
    Xing, L
    Graves, E
    Loo, BW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S506 - S506