Four-dimensional computed tomography: Image formation and clinical protocol

被引:342
|
作者
Rietzel, E [1 ]
Pan, TS
Chen, GTY
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Gesell Schwerionenforsch mbH, Biophys Abt, Darmstadt, Germany
[3] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
4D computed tomography; 4D imagine; time resolved imaging;
D O I
10.1118/1.1869852
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion can introduce significant errors in radiotherapy. Conventional CT scans as commonly used for treatment planning can include severe motion artifacts that result from interplay effects between the advancing scan plane and object motion. To explicitly include organ/target motion in treatment planning and delivery, time-resolved CT data acquisition (4D Computed Tomography) is needed. 4DCT can be accomplished by oversampled CT data acquisition at each slice. During several CT tube rotations projection data are collected in axial cine mode for the duration of the patient's respiratory cycle (plus the time needed for a full CT gantry rotation). Multiple images are then reconstructed per slice that are evenly distributed over the acquisition time. Each of these images represents a different anatomical state during a respiratory cycle. After data acquisition at one couch position is completed, x rays are turned off and the couch advances to begin data acquisition again until full coverage of the scan length has been obtained. Concurrent to CT data acquisition the patient's abdominal surface motion is recorded in precise temporal correlation. To obtain CT volumes at different respiratory states, reconstructed images are sorted into different spatio-temporally coherent volumes based on respiratory phase as obtained from the patient's surface motion. During binning, phase tolerances are chosen to obtain complete volumetric information since images at different couch positions are reconstructed at different respiratory phases. We describe 4DCT image formation and associated experiments that characterize the properties of 4DCT. Residual motion artifacts remain due to partial projection effects. Temporal coherence within resorted 4DCT volumes is dominated by the number of reconstructed images per slice. The more images are reconstructed, the smaller phase tolerances can be for retrospective sorting. From phantom studies a precision of about 2.5 mm. for quasiregular motion and typical respiratory periods could be concluded. A protocol for 4DCT scanning was evaluated and clinically implemented at the MGH. Patient data are presented to elucidate how additional patient specific parameters can impact 4DCT imaging. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:874 / 889
页数:16
相关论文
共 50 条
  • [21] 4D computed tomography: Image formation and clinical protocol
    Rietzel, E
    Pan, T
    Chen, GTY
    MEDICAL PHYSICS, 2004, 31 (06) : 1778 - 1778
  • [22] Performance studies of four-dimensional cone beam computed tomography
    Qi, Zhihua
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : 6709 - 6721
  • [23] Parathyroid Imaging Four-dimensional Computed Tomography, Sestamibi, and Ultrasonography
    Strauss, Sara B.
    Roytman, Michelle
    Phillips, C. Douglas
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2021, 31 (03) : 379 - 395
  • [24] Four-dimensional computed tomography analysis of bicuspid aortic valves
    Fikani, Amine
    Craiem, Damian
    Boulogne, Cyrille
    Soulat, Gilles
    Mousseaux, Elie
    Jouan, Jerome
    JTCVS TECHNIQUES, 2024, 27 : 60 - 67
  • [25] Four-dimensional Computed Tomography for Preoperative Localization of Parathyroid Adenomas
    Zeina, Abdel-Rauf
    Nakar, Helit
    Reindorp, Nadir
    Nachtigal, Alicia
    Krausz, Michael M.
    Ashkenazi, Itamar
    Shapira-Rootman, Mika
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2017, 19 (04): : 216 - 220
  • [26] Four-dimensional computed tomography and detection of dynamic capitate subluxation
    Repse, Stephen E.
    Amis, Benjamin
    Troupis, John M.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (03) : 331 - 335
  • [27] A Four-Dimensional Computed Tomography Analysis of Multiorgan Abdominal Motion
    Hallman, Joshua L.
    Mori, Shinichiro
    Sharp, Gregory C.
    Lu, Hsiao-Ming
    Hong, Theodore S.
    Chen, George T. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01): : 435 - 441
  • [28] Motion artifact detection in four-dimensional computed tomography images
    Bouilhol, G.
    Ayadi, M.
    Pinho, R.
    Rit, S.
    Sarrut, D.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [29] Evaluation of stuck mechanical valve with four-dimensional computed tomography
    Numata, Satoshi
    Tsutsumi, Yasushi
    Ohashi, Hirokazu
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (03) : 594 - 594
  • [30] Dynamic Four-Dimensional Computed Tomography Angiography for Neurovascular Pathologies
    Alnemari, Ahmed
    Mansour, Tarek R.
    Bazerbashi, Mohamad
    Buehler, Mark
    Schroeder, Jason
    Gaudin, Daniel
    WORLD NEUROSURGERY, 2017, 105 : 1034.e11 - 1034.e18