摘要
Metal allergy is an uncommon and poorly understood cause of failure of orthopedic implants. To the authors' knowledge, there have been no reports of the management of shoulder arthroplasty patients with metal allergy. The authors present their experience with the diagnosis and management of patients with metal allergy. Patients with metal allergy undergoing shoulder arthroplasty were identified through retrospective chart review from January 1, 2012, to January 31, 2015. Case characteristics collected included patient risk factors (age, sex, prior cutaneous reactions to metal), metal allergy factors (type of metal allergy, method of diagnosis), and surgery factors (implant type, primary/revision, type of shoulder arthroplasty). Outcomes measured included American Shoulder and Elbow Surgeons score, Penn Shoulder Score, and Single Assessment Numeric Evaluation score. Eleven patients were identified with metal allergy. Five were diagnosed prior to the index arthroplasty, and 6 were diagnosed after shoulder replacement. The diagnosis was made through skin patch testing, memory lymphocyte immunostimulation assay, or clinical history. Patients identified after implantation presented with progressive pain and stiffness, but none had cutaneous manifestations. Patients with metal allergy had better results undergoing primary shoulder arthroplasty than undergoing revision. Metal allergy is rare but may be a clinically significant cause of unsatisfactory shoulder arthroplasty. Given the superior results of primary shoulder arthroplasty compared with revision, screening for metal allergy by clinical history is recommended.
引用
下载
收藏
页码:E844 / E848
页数:5
相关论文
共 50 条
  • [31] Implant Failure. Arthroplasty - Models elsewhere
    不详
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2013, 151 (02): : 116 - 118
  • [32] A STUDY OF IMPLANT FAILURE IN THE WAGNER RESURFACING ARTHROPLASTY
    BELL, RS
    SCHATZKER, J
    FORNASIER, VL
    GOODMAN, SB
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (08): : 1165 - 1175
  • [33] Allergy diagnostics in suspected metal implant intolerance
    Thomas, P.
    Summer, B.
    Krenn, V.
    Thomsen, M.
    ORTHOPADE, 2013, 42 (08): : 602 - 606
  • [34] Long head of the biceps pathology as a cause of anterior shoulder pain after shoulder arthroplasty
    Tuckman, David V.
    Dines, David M.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (04) : 415 - 418
  • [35] Metal implant allergy: A retrospective cohort analysis at a university allergy practice
    Taliercio, Mark J.
    Alnabulsi, Rawaa K.
    Uppal, Priya A.
    Shaw, Ian M.
    Semenza, Kristy M.
    Pasha, Muhammad A.
    ALLERGY AND ASTHMA PROCEEDINGS, 2024, 45 (03) : 186 - 194
  • [36] Complication rate and implant survival for reverse shoulder arthroplasty versus total shoulder arthroplasty: results during the initial 2 years
    Villacis, Diego
    Sivasundaram, Lakshmanan
    Pannell, William C.
    Heckmann, Nathanael
    Omid, Reza
    Hatch, George F. Rick, III
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (06) : 927 - 935
  • [37] Is fibromyalgia a cause of failure in the treatment of a painful shoulder?
    Blonna D.
    Bellato E.
    Marini E.
    Barbasetti N.
    Mattei L.
    Fissore F.
    Arrigoni C.
    Castoldi F.
    MUSCULOSKELETAL SURGERY, 2013, 97 (Suppl 1) : S15 - S22
  • [38] EFFECT OF GLENOID IMPLANT ORIENTATION AND DEPTH ON POTENTIAL CEMENT FAILURE IN TOTAL SHOULDER ARTHROPLASTY USING FINITE ELEMENT ANALYSIS
    Yongpravat, Charlie
    Levine, William N.
    Bigliani, Louis U.
    Gardner, Thomas R.
    Ahmad, Christopher S.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 179 - 180
  • [39] Failure of the Glenoid Component in Anatomic Total Shoulder Arthroplasty
    Papadonikolakis, Anastasios
    Neradilek, Moni Blazej
    Matsen, Frederick A., III
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (24): : 2205 - 2212
  • [40] Revision reverse shoulder arthroplasty for the management of baseplate failure: an analysis of 676 revision reverse shoulder arthroplasty procedures
    Ii, Mitchell P. John
    Mesa, Lazaro
    Simon, Peter
    Frankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2024, 33 (03) : 707 - 714