Metal Allergy as a Cause of Implant Failure in Shoulder Arthroplasty

被引:5
|
作者
Ko, Jia-Wei Kevin [1 ]
Nicholson, Thema A. [1 ]
Hoffler, C. Edward [1 ]
Williams, Gerald, Jr. [1 ]
Getz, Charles [1 ]
机构
[1] Rothman Inst, 925 Chestnut St, Philadelphia, PA 19107 USA
关键词
QUALITY-OF-LIFE; JOINT REPLACEMENT; SENSITIVITY; HYPERSENSITIVITY; VALIDITY; HEMIARTHROPLASTY; OSTEOARTHRITIS; RELIABILITY; PREVALENCE; OUTCOMES;
D O I
10.3928/01477447-20170719-01
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Metal allergy is an uncommon and poorly understood cause of failure of orthopedic implants. To the authors' knowledge, there have been no reports of the management of shoulder arthroplasty patients with metal allergy. The authors present their experience with the diagnosis and management of patients with metal allergy. Patients with metal allergy undergoing shoulder arthroplasty were identified through retrospective chart review from January 1, 2012, to January 31, 2015. Case characteristics collected included patient risk factors (age, sex, prior cutaneous reactions to metal), metal allergy factors (type of metal allergy, method of diagnosis), and surgery factors (implant type, primary/revision, type of shoulder arthroplasty). Outcomes measured included American Shoulder and Elbow Surgeons score, Penn Shoulder Score, and Single Assessment Numeric Evaluation score. Eleven patients were identified with metal allergy. Five were diagnosed prior to the index arthroplasty, and 6 were diagnosed after shoulder replacement. The diagnosis was made through skin patch testing, memory lymphocyte immunostimulation assay, or clinical history. Patients identified after implantation presented with progressive pain and stiffness, but none had cutaneous manifestations. Patients with metal allergy had better results undergoing primary shoulder arthroplasty than undergoing revision. Metal allergy is rare but may be a clinically significant cause of unsatisfactory shoulder arthroplasty. Given the superior results of primary shoulder arthroplasty compared with revision, screening for metal allergy by clinical history is recommended.
引用
收藏
页码:E844 / E848
页数:5
相关论文
共 50 条
  • [1] Failure of an implant after total shoulder arthroplasty - A case report
    Kirk, PG
    Sorger, J
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (04): : 597 - 598
  • [2] BIPOLAR IMPLANT SHOULDER ARTHROPLASTY
    SWANSON, AB
    DEGROOT, G
    MAUPIN, BK
    WEI, JN
    KHALIL, MA
    [J]. ORTHOPEDICS, 1986, 9 (03) : 343 - 351
  • [3] The Humeral Implant in Shoulder Arthroplasty
    Keener, Jay D.
    Chalmers, Peter Nissen
    Yamaguchi, Ken
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2017, 25 (06) : 427 - 438
  • [4] Metal Implant Allergy
    Thomas, Peter
    [J]. ALLERGO JOURNAL, 2007, 16 (04) : 275 - 280
  • [5] Metal Implant Allergy
    Mahmood, Bilal
    Hammert, Warren C.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (04): : 831 - 834
  • [6] Metal implant allergy
    Thomas, P.
    [J]. ALLERGOLOGIE, 2009, 32 (10) : 412 - 412
  • [7] Glenoid implant orientation and cement failure in total shoulder arthroplasty: a finite element analysis
    Yongpravat, Charlie
    Kim, H. Mike
    Gardner, Thomas R.
    Bigliani, Louis U.
    Levine, William N.
    Ahmad, Christopher S.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (07) : 940 - 947
  • [8] Metal implant allergy update
    Thomas, P.
    [J]. HAUTARZT, 2016, 67 (05): : 343 - 346
  • [9] Metal (hardware) implant ''allergy''
    Warmuth, IP
    Beltrani, VS
    [J]. IMMUNOLOGY AND ALLERGY CLINICS OF NORTH AMERICA, 1997, 17 (03) : 487 - +
  • [10] Reverse Total Shoulder Arthroplasty: Implant Design Considerations
    Sheth, Ujash
    Saltzman, Matthew
    [J]. CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2019, 12 (04) : 554 - 561