Microdrop analysis of a bead-based immunoassay

被引:22
|
作者
Thomas, JH [1 ]
Ronkainen-Matsuno, NJ [1 ]
Farrell, S [1 ]
Halsall, HB [1 ]
Heineman, WR [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
关键词
microbead-based immunoassay; electrochemical immunoassay; rotating disk electrodes; microelectrode; interdigitated array electrode;
D O I
10.1016/S0026-265X(03)00036-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The progress to electrochemical detection of a microbead-based immunoassay in small volumes has led to a reduced assay time and lower detection limits. Three electrochemical techniques are described for an immunoassay with detection in a microdrop. The techniques are amperometric detection with a rotating disk electrode (RDE), a microelectrode. and an interdigitated array (IDA) electrode. An enzyme-labeled sandwich immunoassay with mouse IgG as the model analyte is used to demonstrate the three techniques. The microbead assay is carried out in a test tube using a magnet to control bead collection. Once the immunocomplex is formed on the microbead, the beads are transferred to a microdrop where the enzyme, either alkaline phosphatase or beta-galactosidase, generates 4-aminophenol (PAP). PAP is oxidized at the electrode with an applied potential of + 290 mV vs. Ag/AgCl. For all three techniques, the upper limit of the dynamic range was 1000 ng/ml mouse IgG, and the detection limits were: 50 ng/ml for the RDE. 40 ng/ml for the microelectrode, and 26 ng/ml for the IDA electrode. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:267 / 276
页数:10
相关论文
共 50 条
  • [41] Development of a bead-based immunoassay to routinely measure vimentin autoantibodies in the clinical setting
    Fhied, Cristina
    Kanangat, Sivadasan
    Borgia, Jeffrey A.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2014, 407 : 9 - 14
  • [42] A Bead-Based Nonradioactive Immunoassay for Autoantibody Testing in a Mouse Model of Myasthenia Gravis
    Bahauddin, Afrin
    Curtis, Kyra
    Guptarak, Jutatip
    Huda, Ruksana
    ANTIBODIES, 2024, 13 (03)
  • [43] LED Excitation of an On-chip Imaging Flow Cytometer for Bead-based Immunoassay
    Yuan, Xilong
    Darcie, Todd
    Aitchison, J. Stewart
    McKendry, Jonathan J. D.
    Strain, Michael J.
    Dawson, Martin D.
    2020 IEEE PHOTONICS CONFERENCE (IPC), 2020,
  • [44] Evaluation of a bead-based enzyme immunoassay for the rapid detection of osteocalcin in human serum
    Craciun, AM
    Vermeer, C
    Eisenwiener, HG
    Drees, N
    Knapen, MHJ
    CLINICAL CHEMISTRY, 2000, 46 (02) : 252 - 257
  • [45] A Novel Bead-Based Immunoassay for the Measurement of Heat Shock Proteins 27 and 70
    Njemini, Rose
    Verhaeghen, Katrijn
    Mets, Tony
    Weets, Ilse
    Bautmans, Ivan
    PATHOGENS, 2020, 9 (11): : 1 - 15
  • [46] Analysis of individual data from bead-based assays ("bead arrays")
    Jacobson, James W.
    Oliver, Kerry G.
    Weiss, Christy
    Kettman, John
    CYTOMETRY PART A, 2006, 69A (05) : 384 - 390
  • [47] Capture and Detection of Plasmodium vivax Lactate Dehydrogenase in a Bead-Based Multiplex Immunoassay
    Rogier, Eric
    Nace, Doug
    Ljolje, Dragan
    Lucchi, Naomi W.
    Udhayakumar, Venkatachalam
    Aidoo, Michael
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2020, 102 (05): : 1064 - 1067
  • [48] Optoelectrokinetically-Enabled Signal Enhancement for a Bead-Based FRET Fluorescence Immunoassay
    Chuang, Han-Sheng
    Wang, Kuan-Chih
    Hsieh, Dar-Bin
    Fu, Yong Qing
    PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON OPTOMECHATRONIC TECHNOLOGIES (ISOT), 2014, : 101 - 104
  • [49] Ergometrine sensing in rye flour by a magnetic bead-based immunoassay followed by flow injection analysis with amperometric detection
    Hoefs, Soraya
    Jaut, Valerie
    Schneider, Rudolf J.
    TALANTA, 2023, 254
  • [50] Combining dielectrophoresis and concentration polarization-based preconcentration to enhance bead-based immunoassay sensitivity
    Park, Sinwook
    Yossifon, Gitad
    NANOSCALE, 2019, 11 (19) : 9436 - 9443