Microdrop analysis of a bead-based immunoassay

被引:22
|
作者
Thomas, JH [1 ]
Ronkainen-Matsuno, NJ [1 ]
Farrell, S [1 ]
Halsall, HB [1 ]
Heineman, WR [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
关键词
microbead-based immunoassay; electrochemical immunoassay; rotating disk electrodes; microelectrode; interdigitated array electrode;
D O I
10.1016/S0026-265X(03)00036-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The progress to electrochemical detection of a microbead-based immunoassay in small volumes has led to a reduced assay time and lower detection limits. Three electrochemical techniques are described for an immunoassay with detection in a microdrop. The techniques are amperometric detection with a rotating disk electrode (RDE), a microelectrode. and an interdigitated array (IDA) electrode. An enzyme-labeled sandwich immunoassay with mouse IgG as the model analyte is used to demonstrate the three techniques. The microbead assay is carried out in a test tube using a magnet to control bead collection. Once the immunocomplex is formed on the microbead, the beads are transferred to a microdrop where the enzyme, either alkaline phosphatase or beta-galactosidase, generates 4-aminophenol (PAP). PAP is oxidized at the electrode with an applied potential of + 290 mV vs. Ag/AgCl. For all three techniques, the upper limit of the dynamic range was 1000 ng/ml mouse IgG, and the detection limits were: 50 ng/ml for the RDE. 40 ng/ml for the microelectrode, and 26 ng/ml for the IDA electrode. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:267 / 276
页数:10
相关论文
共 50 条
  • [31] Development of a varicella-zoster virus bead-based immunoassay for serosurveys
    Escudero, Nicole
    Padron-Regalado, Eriko
    El-Badry, Elina
    Matson, Zachary
    Sowers, Sun
    Crooke, Stephen
    JOURNAL OF IMMUNOLOGY, 2024, 212 (01):
  • [32] On-chip signal amplification of magnetic bead-based immunoassay by aviating magnetic bead chains
    Jalal, Uddin M.
    Jin, Gyeong Jun
    Eom, Kyu Shik
    Kim, Min Ho
    Shim, Joon S.
    BIOELECTROCHEMISTRY, 2018, 122 : 221 - 226
  • [33] Rapid Bead-Based Immunoassay for Measurement of Mannose-Binding Lectin
    Bay, J. T.
    Garred, P.
    SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 2009, 69 (06) : 570 - 575
  • [34] A high sensitivity bead-based immunoassay with nanofluidic preconcentration for biomarker detection
    Fan, Yu-Jui
    Deng, Chih-Zong
    Chung, Pei-Shan
    Tian, Wei-Cheng
    Sheen, Horn-Jiunn
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 272 : 502 - 509
  • [35] Development and Application of the Metalloprotease Activity Multiplexed Bead-Based Immunoassay (MAMBI)
    Ahrens, Caroline C.
    Chiswick, Evan L.
    Ravindra, Kodihalli C.
    Miller, Miles A.
    Ramseier, Julie Y.
    Isaacson, Keith B.
    Lauffenburger, Douglas A.
    Griffith, Linda G.
    BIOCHEMISTRY, 2019, 58 (38) : 3938 - 3942
  • [36] Bead-based multiplexing
    Perkel, Jeffrey M.
    SCIENTIST, 2006, 20 (08): : 68 - 68
  • [37] Normalization and Statistical Analysis of Multiplexed Bead-based Immunoassay Data Using Mixed-effects Modeling
    Clarke, David C.
    Morris, Melody K.
    Lauffenburger, Douglas A.
    MOLECULAR & CELLULAR PROTEOMICS, 2013, 12 (01) : 245 - 262
  • [38] Multiplexed bead-based immunoassay of four serum biomarkers for diagnosis of ovarian cancer
    Kim, Yong-Wan
    Bae, Su Mi
    Kim, In-Wook
    Liu, Hai-Bo
    Bang, Hyo Joo
    Chaturvedi, Pankaj Kumar
    Battogtokh, Gantumur
    Lim, Hyunsun
    Ahn, Woong Shick
    ONCOLOGY REPORTS, 2012, 28 (02) : 585 - 591
  • [39] Bead-based cellular analysis, sorting and multiplexing
    Sanchez-Martin, RM
    Muzerelle, M
    Chitkul, N
    How, SE
    Mittoo, S
    Bradley, M
    CHEMBIOCHEM, 2005, 6 (08) : 1341 - 1345
  • [40] Determination of echinococcosis IgG antibodies using magnetic bead-based chemiluminescence immunoassay
    Chen, Cuicui
    Liang, Huankun
    Peng, Fenglan
    Zhong, Shuhai
    Lu, Yanhong
    Guo, Guiling
    Li, Laiqing
    JOURNAL OF IMMUNOLOGICAL METHODS, 2023, 520