Noncoplanar Beam Angle Class Solutions to Replace Time-Consuming Patient-Specific Beam Angle Optimization in Robotic Prostate Stereotactic Body Radiation Therapy

被引:16
|
作者
Rossi, Linda [1 ]
Breedveld, Sebastiaan [1 ]
Aluwini, Shafak [1 ]
Heijmen, Ben [1 ]
机构
[1] Erasmus MC, Inst Canc, Dept Radiat Oncol, NL-3075 EA Rotterdam, Netherlands
关键词
CANCER; RADIOTHERAPY; IMRT; COPLANAR; GENERATION; TOXICITY; QUALITY;
D O I
10.1016/j.ijrobp.2015.03.013
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate development of a recipe for the creation of a beam angle class solution (CS) for noncoplanar prostate stereotactic body radiation therapy to replace time-consuming individualized beam angle selection (iBAS) without significant loss in plan quality, using the in-house "Erasmus-iCycle" optimizer for fully automated beam profile optimization and iBAS. Methods and Materials: For 30 patients, Erasmus-iCycle was first used to generate 15-, 20-, and 25-beam iBAS plans for a CyberKnife equipped with a multileaf collimator. With these plans, 6 recipes for creation of beam angle CSs were investigated. Plans of 10 patients were used to create CSs based on the recipes, and the other 20 to independently test them. For these tests, Erasmus-iCycle was also used to generate intensity modulated radiation therapy plans for the fixed CS beam setups. Results: Of the tested recipes for CS creation, only 1 resulted in 15-, 20-, and 25-beam noncoplanar CSs without plan deterioration compared with iBAS. For the patient group, mean differences in rectum D-1cc, V-60GyEq, V-40GyEq, and D-mean between 25-beam CS plans and 25-beam plans generated with iBAS were 0.2 +/- 0.4 Gy, 0.1% +/- 0.2%, 0.2% +/- 0.3%, and 0.1 +/- 0.2 Gy, respectively. Differences between 15- and 20-beam CS and iBAS plans were also negligible. Plan quality for CS plans relative to iBAS plans was also preserved when narrower planning target volume margins were arranged and when planning target volume dose inhomogeneity was decreased. Using a CS instead of iBAS reduced the computation time by a factor of 14 to 25, mainly depending on beam number, without loss in plan quality. Conclusions: A recipe for creation of robust beam angle CSs for robotic prostate stereotactic body radiation therapy has been developed. Compared with iBAS, computation times decreased by a factor 14 to 25. The use of a CS may avoid long planning times without losses in plan quality. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:762 / 770
页数:9
相关论文
共 12 条
  • [1] Prioritizing Patient-Specific Geometry: Beam Angle Optimization in Stereotactic Radiosurgery
    Mann, T.
    Ploquin, N.
    Thind, K.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E474 - E474
  • [2] Fast stereotactic radiosurgery planning using patient-specific beam angle optimization and automation
    Mann, Thomas D.
    Thind, Kundan S.
    Ploquin, Nicolas P.
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 21 : 90 - 95
  • [3] Development of a beam angle class solution to replace full beam angle optimization in non-coplanar prostate SBRT
    Rossi, L.
    Breedveld, S.
    Aluwini, S.
    Heijmen, B. J. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S67 - S68
  • [4] Patient-Specific Rectal Toxicity Predictor Based Plan Quality Control for Prostate Stereotactic Body Radiation Therapy (SBRT)
    Song, T.
    Li, Y.
    Zhou, L.
    Jiang, S.
    Gu, X.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3211 - 3211
  • [5] A data-driven approach to optimal beam/arc angle selection for liver stereotactic body radiation therapy treatment planning
    Sheng, Yang
    Li, Taoran
    Ge, Yaorong
    Lin, Hui
    Wang, Wentao
    Yuan, Lulin
    Wu, Q. Jackie
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (12) : 4797 - 4806
  • [6] Learning-based Real-time Patient-specific Volumetric Imaging for Lung Stereotactic Body Radiation Therapy
    Yang, X.
    Lei, Y.
    Tian, Z.
    Roper, J. R.
    Wang, T.
    Higgins, K. A.
    Shelton, J. W.
    Bradley, J. D.
    Curran, W. J., Jr.
    Liu, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E345 - E346
  • [7] Real-Time Patient-Specific Volumetric Imaging for Lung Stereotactic Body Radiation Therapy Via InferGAN with Perceptual Supervision
    Lei, Y.
    Tian, Z.
    Wang, T.
    Roper, J.
    Higgins, K.
    Bradley, J.
    Curran, W.
    Liu, T.
    Yang, X.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E361 - E361
  • [8] Similar-cases-based planning approaches with beam angle optimizations using water equivalent path length for lung stereotactic body radiation therapy
    Haseai, Shu
    Arimura, Hidetaka
    Asai, Kaori
    Yoshitake, Tadamasa
    Shioyama, Yoshiyuki
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (02) : 119 - 127
  • [9] Similar-cases-based planning approaches with beam angle optimizations using water equivalent path length for lung stereotactic body radiation therapy
    Shu Haseai
    Hidetaka Arimura
    Kaori Asai
    Tadamasa Yoshitake
    Yoshiyuki Shioyama
    [J]. Radiological Physics and Technology, 2020, 13 : 119 - 127
  • [10] Similar-Case-Based Framework of Beam Angle Configurations Using Treatment-Plan-Related Features in Lung Stereotactic Body Radiation Therapy
    Imai, M.
    Arimura, H.
    Nonaka, A.
    Nakamura, K.
    Shioyama, Y.
    Honda, H.
    Hirata, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3496 - 3497