Similar-cases-based planning approaches with beam angle optimizations using water equivalent path length for lung stereotactic body radiation therapy

被引:0
|
作者
Shu Haseai
Hidetaka Arimura
Kaori Asai
Tadamasa Yoshitake
Yoshiyuki Shioyama
机构
[1] SAGA Heavy Ion Medical Accelerator in Tosu,Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences
[2] Kyushu University,undefined
来源
关键词
Automated treatment planning; Similar cases; Lung stereotactic body radiation therapy; Optimization; Water equivalent path length;
D O I
暂无
中图分类号
学科分类号
摘要
This study aimed to propose automated treatment planning approaches based on similar cases with beam angle optimizations using water equivalent path length (WEPL) to avoid lung and rib doses for lung stereotactic body radiation therapy (SBRT). Similar cases to an objective case were defined as cases, which were close to the objective case with respect to the Euclidean distances based on geometrical features. Initial similar-case-based (ISC) plans were generated by applying lung SBRT plans of similar cases to objective cases. Similar cases were selected using the Euclidean distances based on lung shape and geometrical features from a radiation treatment planning database with 174 cases. Beam angles of the ISC plans were optimized using a greedy algorithm based on a cost function to include absorbed doses in the lung and ribs in the WEPL. The 12 dose evaluation indices for the planning target volume, lung, spinal cord, and ribs were evaluated in the original plans, ISC plans, and optimized similar-case-based (OSC) plans with and without WEPL for 20 test cases to investigate its dosimetric impact. These findings revealed that V10 and the mean dose for the lung and V20, V30, and V40 for the ribs in the OSC plan with WEPL improved more significantly than those in the original and ISC plans. This study indicates a potential of similar cases, whose beam angle configurations were optimized with WEPL to avoid lung and rib doses in lung SBRT plans.
引用
收藏
页码:119 / 127
页数:8
相关论文
共 50 条
  • [1] Similar-cases-based planning approaches with beam angle optimizations using water equivalent path length for lung stereotactic body radiation therapy
    Haseai, Shu
    Arimura, Hidetaka
    Asai, Kaori
    Yoshitake, Tadamasa
    Shioyama, Yoshiyuki
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (02) : 119 - 127
  • [2] Automated Treatment Planning Approach with Beam Angles Optimization to Avoid Rib Bones Based On Similar Cases for Lung Stereotactic Body Radiation Therapy
    Haseai, S.
    Arimura, H.
    Imai, M.
    Yoshitake, T.
    Shioyama, Y.
    Honda, H.
    Ohga, S.
    Sasaki, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2967 - 2967
  • [3] Computer-aided beam arrangement based on similar cases in radiation treatment-planning databases for stereotactic lung radiation therapy
    Magome, Taiki
    Arimura, Hidetaka
    Shioyama, Yoshiyuki
    Mizoguchi, Asumi
    Tokunaga, Chiaki
    Nakamura, Katsumasa
    Honda, Hiroshi
    Ohki, Masafumi
    Toyofuku, Fukai
    Hirata, Hideki
    [J]. JOURNAL OF RADIATION RESEARCH, 2013, 54 (03) : 569 - 577
  • [4] Similar-Case-Based Framework of Beam Angle Configurations Using Treatment-Plan-Related Features in Lung Stereotactic Body Radiation Therapy
    Imai, M.
    Arimura, H.
    Nonaka, A.
    Nakamura, K.
    Shioyama, Y.
    Honda, H.
    Hirata, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3496 - 3497
  • [5] Similar-Case-Based Optimization of Beam Arrangements in Stereotactic Body Radiation Therapy
    Magome, T.
    Arimura, H.
    Shioyama, Y.
    Mizoguchi, A.
    Tokunaga, C.
    Nakamura, K.
    Honda, H.
    Ohki, M.
    Toyofuku, F.
    Hirata, H.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3908 - 3908
  • [6] Computer-assisted radiation treatment planning system for determination of beam directions based on similar cases in a database for stereotactic body radiotherapy
    Magome, Taiki
    Arimura, Hidetaka
    Shioyama, Yoshiyuki
    Mizoguchi, Asumi
    Tokunaga, Chiaki
    Nakamura, Katsumasa
    Honda, Hiroshi
    Ohki, Masafumi
    Toyofuku, Fukai
    Hirata, Hideki
    [J]. MEDICAL IMAGING 2012: ADVANCED PACS-BASED IMAGING INFORMATICS AND THERAPEUTIC APPLICATIONS, 2012, 8319
  • [7] Stereotactic Body Radiation Therapy for Lung Cancer and Lung Metastases Using Megavoltage Cone Beam (MVCB)
    Mut, A.
    Chust, M.
    Crispin, V.
    Mengual, J.
    Guinot, J.
    Pesudo, C.
    Gonzalez, V.
    Pastor, V.
    Abad, D.
    Arribas, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S731 - S732
  • [8] Adaptive Planning of Lung Stereotactic Body Radiation Therapy Patients Based On Target Excursion and Deformation
    Saleh, H.
    Wang, F.
    Soultan, D.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E694 - E694
  • [9] Dosimetric analysis of lung cancer treatment planning for stereotactic body radiation therapy utilizing cone beam CT
    Patel, S. H.
    Hammoud, R.
    Ajlouni, M.
    Guan, H.
    Pradhan, D.
    Movsas, B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S652 - S652
  • [10] Automated Determination of Beans Arrangement Based on Similar Cases in Radiotherapy Treatment Planning Database for Lung Stereotactic Body Radiotherapy
    Magome, T.
    Arimura, H.
    Shioyama, Y.
    Tokunaga, C.
    Nakamura, K.
    Anai, S.
    Honda, H.
    Ohki, M.
    Toyofuku, F.
    Hirata, H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S860 - S861