Fast stereotactic radiosurgery planning using patient-specific beam angle optimization and automation

被引:1
|
作者
Mann, Thomas D. [1 ,2 ]
Thind, Kundan S. [1 ,3 ,4 ]
Ploquin, Nicolas P. [1 ,2 ,3 ]
机构
[1] Univ Calgary, Dept Phys & Astron, Calgary, AB, Canada
[2] Tom Baker Canc Clin, Dept Med Phys, Calgary, AB, Canada
[3] Univ Calgary, Dept Radiat Oncol, Calgary, AB, Canada
[4] Henry Ford Hlth Syst, Dept Med Phys, Detroit, MI USA
关键词
Radiosurgery; Organs at risk; Heuristics; Retrospective studies; Particle accelerators; Automation; MODULATED ARC THERAPY; METASTASES; TRAJECTORIES; QUALITY;
D O I
10.1016/j.phro.2022.02.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Linac-based stereotactic radiosurgery (SRS) planning for multi-metastatic cases is a complex and intensive process. A manual planning strategy starts with a template-based set of beam angles and applies modifications though a trial and error process. Beam angle optimization uses patient specific geometric heuristics to determine beam angles that provide optimal target coverage and avoid treating through Organs-at Risk (OARs). This study expands on a collision prediction application developed using an application programming interface, integrating beam angle optimization and collision prediction into a Stereotactic Optimized Automated Radiotherapy (SOAR) planning algorithm. Materials and methods: Twenty-five patient plans, previously treated with SRS for multi-metastatic intracranial tumors, were selected for a retrospective plan study comparing the manual planning strategy to SOAR. The SOAR algorithm was used to select isocenters, table, collimator, and gantry angles, and target groupings for the optimized plans. Dose-volume metrics for relevant OARs and PTVs were compared using double-sided Wilcoxon signed rank tests (alpha = 0.05). A subset of five patients were included in an efficiency study comparing manual planning times to SOAR automated times. Results: OAR dose metrics compared between planning strategies showed no statistical difference for the dataset of twenty-five plans. Differences in maximum PTV dose and the conformity index were improved for SOAR planning and statistically significant. The median SOAR planning time was 9.8 min compared to 55 min for the manual planning strategy. Conclusions: SOAR planning was comparable in plan quality to a manual planning strategy with the possibility for greatly improving planning efficiency through automation.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 50 条
  • [1] Prioritizing Patient-Specific Geometry: Beam Angle Optimization in Stereotactic Radiosurgery
    Mann, T.
    Ploquin, N.
    Thind, K.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E474 - E474
  • [2] Noncoplanar Beam Angle Class Solutions to Replace Time-Consuming Patient-Specific Beam Angle Optimization in Robotic Prostate Stereotactic Body Radiation Therapy
    Rossi, Linda
    Breedveld, Sebastiaan
    Aluwini, Shafak
    Heijmen, Ben
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 92 (04): : 762 - 770
  • [3] Fast Robust Optimization using a Patient-Specific Scenario Selection Methodology
    Buti, G.
    Souris, K.
    Lee, J. A.
    Sterpin, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S987 - S988
  • [4] Patient-specific prediction of SEEG electrode bending for stereotactic neurosurgical planning
    Granados, Alejandro
    Han, Yuxuan
    Lucena, Oeslle
    Vakharia, Vejay
    Rodionov, Roman
    Vos, Sjoerd B.
    Miserocchi, Anna
    McEvoy, Andrew W.
    Duncan, John S.
    Sparks, Rachel
    Ourselin, Sebastien
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2021, 16 (05) : 789 - 798
  • [5] Patient-specific prediction of SEEG electrode bending for stereotactic neurosurgical planning
    Alejandro Granados
    Yuxuan Han
    Oeslle Lucena
    Vejay Vakharia
    Roman Rodionov
    Sjoerd B. Vos
    Anna Miserocchi
    Andrew W. McEvoy
    John S. Duncan
    Rachel Sparks
    Sébastien Ourselin
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2021, 16 : 789 - 798
  • [6] Stereotactic Radiosurgery for AMD: A Monte Carlo-Based Assessment of Patient-Specific Tissue Doses
    Hanlon, Justin
    Firpo, Michael
    Chell, Erik
    Moshfeghi, Darius M.
    Bolch, Wesley E.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2334 - 2342
  • [7] Patient-specific quantification of cardiorespiratory motion for cardiac stereotactic radioablation treatment planning
    Petzl, Adrian
    Benali, Karim
    Mbolamena, Nicolas
    Dyrda, Katia
    Rivard, Lena
    Seidl, Sebastian
    Martins, Raphael
    Martinek, Martin
    Puererfellner, Helmut
    Aguilar, Martin
    [J]. HEART RHYTHM O2, 2024, 5 (04): : 234 - 242
  • [8] On the evaluation of edgeless diode detectors for patient-specific QA in high-dose stereotactic radiosurgery
    De Martin, Elena
    Alhujaili, Sultan
    Fumagalli, Maria Luisa
    Ghielmetti, Francesco
    Marchetti, Marcello
    Gallo, Pasqualina
    Aquino, Domenico
    Padelli, Francesco
    Davis, Jeremy
    Alnaghy, Saree
    Carrara, Mauro
    Fariselli, Laura
    Rosenfeld, Anatoly B.
    Petasecca, Marco
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 89 : 20 - 28
  • [9] Evaluating stereotactic accuracy with patient-specific MRI distortion corrections for frame-based radiosurgery
    Knill, Cory
    Halford, Robert
    Sandhu, Raminder
    Loughery, Brian
    Shamim, Sharjil
    Junn, Fred
    Lee, Kuei
    Almahariq, Muayad
    Seymour, Zachary
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024,
  • [10] IMRT planning parameter optimization for spine stereotactic radiosurgery
    Ayala, Gabriel B.
    Doan, Kieu A.
    Ko, Hie Ji
    Park, Peter K.
    Santiago, Edwin D.
    Kuruvila, Shiny J.
    Ghia, Amol J.
    Briere, Tina M.
    Wen, Zhifei
    [J]. MEDICAL DOSIMETRY, 2019, 44 (04) : 303 - 308