Reproducibility of laboratory scanning of multiple implants in complete edentulous arch: Effect of scan bodies

被引:16
|
作者
Pan, Yu [1 ]
Tam, Juliana M. Y. [2 ]
Tsoi, James K. H. [1 ]
Lam, Walter Y. H. [1 ]
Pow, Edmond H. N. [1 ]
机构
[1] Univ Hong Kong, Fac Dent, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Ind Ctr, Hong Kong, Peoples R China
关键词
Reproducibility; Accuracy; Scan bodies; Digitalization; Complete arch; LONG-SPAN ZIRCONIA; 3-DIMENSIONAL ACCURACY; TOLERANCE MEASUREMENTS; IMPRESSIONS; MISFIT; PROSTHESES; FRAMEWORKS; FIT;
D O I
10.1016/j.jdent.2020.103329
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the reproducibility of complete arch scanning with multiple implant scan bodies using a laboratory scanner. Methods: A master model of edentulous maxillary arch with 6 implants was fabricated. PEEK scan bodies were inserted into the model and consecutively scanned using a dental laboratory scanner (N = 10, Group C). Another 10 scans were performed with each scan body detached and reinserted into the same site between each scan (Group CR). The last group of scanning was performed with the scan bodies detached and randomly repositioned between each scan (N = 10, Group RR). Virtual models were created and the inter-implant distances and angles were measured using an inspection software. Accuracy of the complete arch scans was calculated and compared using Two-Way ANOVA (alpha = 0.05). Results: Significant greater distance distortion was found in CR (27.6 +/- 18.9 mu m) and RR (34.2 +/- 25.0 mu m). No significant difference in angular distortion was found among 3 groups. The greatest distance distortion was found in the anterior and cross-arch region of the arch. The smallest angular distortion was found in the first scanned sextant, with increasing distortion along the scanning path of the arch. The distance precision was significantly reduced in group CR and RR, while the angular precision was significantly reduced in group RR only. Conclusion: Reproducibility of complete arch scanning was significantly affected by repositioning of the scan bodies using a laboratory scanner. Repeated and random repositioning of the scan bodies would decrease the reproducibility of the spatial position and angle of the virtual implant. The distortion appeared to be small and within the clinical tolerance. Clinical significance: High-precision transfer of the implant information from intra-oral environment to dental laboratory is a prerequisite for the success of implant-supported prosthesis. Although laboratory scanners seem to be accurate, their accuracy is also affected by the precision and attachment procedure of the implant scan bodies and that has always been overlooked.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Evaluation the Scanning Accuracy of Blue-Light Laboratory Scanners in Complete Edentulous Maxilla with Multiple Implants with Titanium Scan Bodies
    Ezmek, Bahadir
    Sipahi, Osman Cumhur
    [J]. ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2023, 25 (03) : 55 - 66
  • [2] Effect of novel prefabricated auxiliary devices attaching to scan bodies on the accuracy of intraoral scanning of complete-arch with multiple implants: An in-vitro study
    Wu, Hio Kuan
    Wang, Jing
    Chen, Guanhui
    Huang, Xiaoqiong
    Deng, Feilong
    Li, Yiming
    [J]. JOURNAL OF DENTISTRY, 2023, 138
  • [3] In vitro scanning accuracy using different aids for multiple implants in the edentulous arch
    Kernen, Florian R.
    Recca, Mario
    Vach, Kirstin
    Nahles, Susanne
    Nelson, Katja
    Fluegge, Tabea, V
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (10) : 1010 - 1020
  • [4] Enhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study
    Kernen, Florian
    Braendle, Dominik
    Wagendorf, Oliver
    Recca, Mario
    Mehrhof, Juergen
    Vach, Kirstin
    Nahles, Susanne
    Nelson, Katja
    Fluegge, Tabea
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (08) : 793 - 801
  • [5] A Paradigm Shift Using Scan Bodies to Record the Position of a Complete Arch of Implants in a Digital Workflow
    Giglio, Graziano D.
    Giglio, Ana Becil
    Tarnow, Dennis P.
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 44 (01) : 115 - 126
  • [6] Accuracy of Complete-Arch Implant Digital Scans: Effect of Scanning Protocol, Number of Implants, and Scan Body Splinting
    Denneulin, Thomas
    Rignon-Bret, Christophe
    Ravalec, Guy
    Tapie, Laurent
    Bouter, Denis
    Wulfman, Claudine
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (02) : 219 - 227
  • [7] Accuracy of Impressions of Multiple Implants in the Edentulous Arch: A Systematic Review
    Baig, Mirza Rustum
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (04) : 869 - 880
  • [8] Accuracy and reproducibility of virtual edentulous casts created by laboratory impression scan protocols
    Peng, Lingyan
    Chen, Li
    Harris, Bryan T.
    Bhandari, Bikash
    Morton, Dean
    Lin, Wei-Shao
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 389 - 395
  • [9] Influence of the Number of Scan Bodies on Full-Arch Implant Scanning: A Comparison of 2 vs 4 Implants
    Abdelrehim, Aly
    Salleh, Nosizana Mohd
    Sofian, Hazrina
    Sulaiman, Eshamsul
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (02) : 104 - 110
  • [10] Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses
    Mizumoto, Ryan M.
    Yilmaz, Burak
    McGlumphy, Edwin A., Jr.
    Seidt, Jeremy
    Johnston, William M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 96 - 104