Whole-Brain Cerebral Blood Flow Mapping Using 3D Echo Planar Imaging and Pulsed Arterial Tagging

被引:22
|
作者
Gai, Neville D. [1 ]
Talagala, S. Lalith [2 ]
Butman, John A. [1 ]
机构
[1] NIH, Ctr Clin, Bethesda, MD 20892 USA
[2] NINDS, NIH MRI Res Facil, NIH, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
arterial spin labeling; 3D PULSAR; blurring reduction; whole brain perfusion imaging; LABELING PERFUSION MEASUREMENTS; MRI; SIGNAL; INVERSION;
D O I
10.1002/jmri.22437
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantitate cerebral blood flow (CBF) in the entire brain using the 3D echo planar imaging (EPI) PULSAR (pulsed star labeling) technique. Materials and Methods: The PULSAR technique was modified to 1) incorporate a nonselective inversion pulse to suppress background signal; 2) to use 3D EPI acquisition; and 3) to modulate flip angle in such a manner as to minimize the blurring resulting from T1 modulation along the slice encoding direction. Computation of CBF was performed using the general kinetic model (GKM). In a series of healthy volunteers (n = 12), we first investigated the effects of introducing an inversion pulse on the measured value of CBF and on the temporal stability of the perfusion signal. Next we investigated the effect of flip angle modulation on the spatial blurring of the perfusion signal. Finally, we evaluated the repeatability of the CBF measurements, including the influence of the measurement of arterial blood magnetization (a calibration factor for the GKM). Results: The sequence provides sufficient perfusion signal to achieve whole brain coverage in approximate to 5 minutes. Introduction of the inversion pulse for background suppression did not significantly affect computed CBF values, but did reduce the fluctuation in the perfusion signal. Flip angle modulation reduced blurring, resulting in higher estimates of gray matter (GM) CBF and lower estimates of white matter (WM) CBF. The repeatability study showed that measurement of arterial blood signal did not result in significantly higher error in the perfusion measurement. Conclusion: Improvements in acquisition and sequence preparation presented here allow for better quantification and localization of perfusion signal, allowing for accurate whole-brain CBF measurements in 5 minutes.
引用
收藏
页码:287 / 295
页数:9
相关论文
共 50 条
  • [41] 3D MRI of whole-brain water permeability with intrinsic diffusivity encoding of arterial labeled spin (IDEALS)
    Wengler, Kenneth
    Bangiyev, Lev
    Canli, Turhan
    Duong, Tim Q.
    Schweitzer, Mark E.
    He, Xiang
    [J]. NEUROIMAGE, 2019, 189 : 401 - 414
  • [42] Detection of Small Metastatic Brain Tumors Comparison of 3D Contrast-Enhanced Whole-Brain Black-Blood Imaging and MP-RAGE Imaging
    Park, Jaeseok
    Kim, Jinna
    Yoo, Eunhye
    Lee, Hyunyeol
    Chang, Jong-Hee
    Kim, Eung Yeop
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (02) : 136 - 141
  • [43] Whole-brain quantitative mapping of metabolites using short echo three-dimensional proton MRSI
    Lecocq, Angele
    Le Fur, Yann
    Maudsley, Andrew A.
    Le Troter, Arnaud
    Sheriff, Sulaiman
    Sabati, Mohamad
    Donnadieu, Maxime
    Confort-Gouny, Sylviane
    Cozzone, Patrick J.
    Guye, Maxime
    Ranjeva, Jean-Philippe
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) : 280 - 289
  • [44] WHOLE-BRAIN BLOOD-FLOW AND CEREBRAL METABOLIC DYSFUNCTION DURING MODERATE AND SEVERE STARVATION
    DELAMONTE, SM
    GJEDDE, A
    CARONNA, JJ
    DUFFY, TE
    PLUM, F
    [J]. NEUROLOGY, 1977, 27 (04) : 398 - 399
  • [45] Whole-brain 3D FLAIR at 7T using direct signal control
    Beqiri, Arian
    Hoogduin, Hans
    Sbrizzi, Alessandro
    Hajnal, Joseph V.
    Malik, Shaihan J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) : 1533 - 1545
  • [46] Efficient radiation dose reduction in whole-brain CT perfusion imaging using a 3D GAN: performance and clinical feasibility
    Dashtbani Moghari, Mahdieh
    Zhou, Luping
    Yu, Biting
    Young, Noel
    Moore, Krystal
    Evans, Andrew
    Fulton, Roger R.
    Kyme, Andre Z.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [47] 3D ECHO-PLANAR IMAGING - APPLICATION TO THE HUMAN HEAD
    ABDULJALIL, AM
    ALETRAS, AH
    ROBITAILLE, PML
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) : 144 - 148
  • [48] Simultaneous Arterial and Venous Imaging Using 3D Quantitative Parameter Mapping
    Amemiya, Tomoki
    Yokosawa, Suguru
    Taniguchi, Yo
    Sato, Ryota
    Soutome, Yoshihisa
    Ochi, Hisaaki
    Shirai, Toru
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, : 56 - 65
  • [49] Simultaneous Arterial and Venous Imaging Using 3D Quantitative Parameter Mapping
    Amemiya, Tomoki
    Yokosawa, Suguru
    Taniguchi, Yo
    Sato, Ryota
    Soutome, Yoshihisa
    Ochi, Hisaaki
    Shirai, Toru
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024, 23 (01) : 56 - 65
  • [50] FUNCTIONAL MAPPING OF HAND REPRESENTATION IN THE HUMAN BRAIN WITH ECHO-PLANAR IMAGING OF BLOOD OXYGENATION
    LEBIHAN, DJ
    JEZZARD, P
    ZEFFIRO, T
    TURNER, R
    [J]. RADIOLOGY, 1992, 185 : 198 - 198