Diffusion-based multi-stream bioluminescent reaction in a microfluidic device

被引:9
|
作者
Lee, Tae-Woo [1 ]
Kim, Han-Sung [1 ]
Thuan-Hieu Tran [2 ]
Jang, Jaesung [3 ]
Yoon, Dae Sung [1 ]
Kim, Jin-Hwan [4 ]
Kim, Eun-Ki [2 ]
Koo, Yoon-Mo [2 ,5 ]
Lee, Sang Woo [1 ]
Chang, Woo-Jin [6 ]
机构
[1] Yonsei Univ, Dept Biomed Engn, Wonju 220710, Gangwondo, South Korea
[2] Inha Univ, Dept Biol Engn, Inchon 402751, South Korea
[3] Ulsan Natl Inst Sci & Technol UNIST, Sch Mech & Adv Mat Engn, Ulsan 689798, South Korea
[4] Sungkyunkwan Univ, Dept Polymer Sci & Engn, Suwon 440746, South Korea
[5] Inha Univ, ERC Adv Bioseparar Technol, Inchon 402751, South Korea
[6] Univ Wisconsin, Sch Freshwater Sci, Dept Mech Engn, Milwaukee, WI 53211 USA
关键词
Bioluminescence; ATP; Luciferase; Microfluidic device; Continuous flow; Fluidic condition; Multi-stream; CAPILLARY-ELECTROPHORESIS; CHIP; DNA; LUCIFERASE; SEPARATION; MICROCHIP; SYSTEM; ATP; MANIPULATION; FRAGMENTS;
D O I
10.1016/j.cej.2012.01.055
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, we report the effect of the number and position of the adenosine triphosphate (ATP) and luciferase streams on the diffusion-based continuous bioluminescent reaction in a microchannel. The detectable bioluminescent reaction between substrate (ATP) and enzyme (luciferase) was maximized when the total flow rate of the substrate and the enzyme solution was around 3 and 8 mu l/min for the 2- and 3-stream configurations, respectively. Most of the light was generated inside the luciferase phase, because the diffusion of over 100 times smaller ATP than luciferase into luciferase phase is a limiting factor of continuous flow bioluminescence reaction in microchannel. The diffusion-based reaction of luciferase was enhanced by increasing the number of streams from 2 to 3. The bioluminescence was higher up to 41% when ATP solution was infused as a middle of three streams (L_A_L configuration) comparing with the A_L_A configuration. The optimized flow rates of ATP and luciferase solutions on a thick poly(dimethylsiloxane) layer were obtained as 0.15 mu l,/min:0.7 mu l/min:0.15 mu l/min for luciferase:ATP:luciferase solutions, respectively. In addition, a diffusion-based simulation model was developed for the characterization of the bioluminescent reaction in a microchannel. The numerical simulation using the model was closely matched with the experimental results with 0.01 level significant correlations in bivariate correlation coefficient analysis. The reaction between ATP and the luciferase solution in a microfluidic device can be used for a flow-type bioluminescence sensor for rapid detection of cells. Published by Elsevier B.V.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 50 条
  • [21] Diffusion-based humidity control membrane for microfluidic-based gas detectors
    Paknahad, Mohammad
    Bachhal, Jannat Singh
    Hoorfar, Mina
    [J]. ANALYTICA CHIMICA ACTA, 2018, 1021 : 103 - 112
  • [22] Mass diffusion-based separation of sugars in a microfluidic contactor with nanofiltration membranes
    Kolfschoten, Ruben C.
    Janssen, Anja E. M.
    Boom, Remko M.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2011, 34 (11) : 1338 - 1346
  • [23] Diffusion-based microfluidic PCR for "one-pot" analysis of cells
    Ma, Sai
    Loufakis, Despina Nelie
    Cao, Zhenning
    Chang, Yiwen
    Achenie, Luke E. K.
    Lu, Chang
    [J]. LAB ON A CHIP, 2014, 14 (16) : 2905 - 2909
  • [24] Hierarchical multi-stream posterior based speech recognition system
    Ketabdar, H
    Bourlard, H
    Bengio, S
    [J]. MACHINE LEARNING FOR MULTIMODAL INTERACTION, 2005, 3869 : 294 - 306
  • [25] Multi-stream HMM for EMG-based speech recognition
    Manabe, H
    Zhang, Z
    [J]. PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 4389 - 4392
  • [26] Part-based Multi-stream Model for Vehicle Searching
    Sun, Ya
    Li, Minxian
    Lu, Jianfeng
    [J]. 2018 24TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR), 2018, : 1372 - 1377
  • [27] A Rough-Set-based Clustering Algorithm for Multi-stream
    Zhou, Haiyan
    Bai, Xiaolin
    Shan, Jinsong
    [J]. CEIS 2011, 2011, 15
  • [28] Immune response to IL6 gradient in a diffusion-based microfluidic labchip
    Sardarabadi, Parvaneh
    Lee, Kang-Yun
    Sun, Wei-Lun
    Liu, Cheng-Hsien
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2024, 417
  • [29] Multi-stream CNN based Video Semantic Segmentation for Automated Driving
    Sistu, Ganesh
    Chennupati, Sumanth
    Yogamani, Senthil
    [J]. PROCEEDINGS OF THE 14TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS (VISAPP), VOL 5, 2019, : 173 - 180
  • [30] Object Tracking Algorithm Based on Multi-Stream Attention Siamese Network
    Yu, Lubin
    Tian, Lianfang
    Du, Qiliang
    [J]. Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2022, 50 (12): : 30 - 40