Optimizing MRI sequences and images for MRI-based stereotactic radiosurgery treatment planning

被引:13
|
作者
Taghizadeh, Somayeh [1 ,2 ,4 ,5 ]
Labuda, Cecille [4 ,5 ]
Yang, Claus Chunli [1 ]
Morris, Bart [1 ]
Kanakamedala, Madhava R. [1 ]
Vijayakumar, Srinivasan [1 ]
Rey-Dios, Roberto [1 ,3 ]
Duggar, William N. [1 ]
Florez, Edward [2 ]
Fatemi, Ali [1 ,2 ]
机构
[1] Univ Mississippi, Med Ctr, Dept Radiat Oncol, 2500 North State St, Jackson, MS 39216 USA
[2] Univ Mississippi, Med Ctr, Dept Radiol, Jackson, MS 39216 USA
[3] Univ Mississippi, Med Ctr, Dept Neurosurg, Jackson, MS 39216 USA
[4] Univ Mississippi, Natl Ctr Phys Acoust, Jackson, MS 38655 USA
[5] Univ Mississippi, Dept Phys & Astron, Jackson, MS 38655 USA
关键词
MRI; Stereotactic radiosurgery planning; Tumor; COMPLETE DISTORTION CORRECTION; POINT-SPREAD FUNCTION; GEOMETRIC DISTORTION;
D O I
10.1016/j.rpor.2018.09.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: Development of MRI sequences and processing methods for the production of images appropriate for direct use in stereotactic radiosurgery (SRS) treatment planning. Background: MRI is useful in SRS treatment planning, especially for patients with brain lesions or anatomical targets that are poorly distinguished by CT, but its use requires further refinement. This methodology seeks to optimize MRI sequences to generate distortion-free and clinically relevant MR images for MRI-only SRS treatment planning. Materials and methods: We used commercially available SRS MRI-guided radiotherapy phantoms and eight patients to optimize sequences for patient imaging. Workflow involved the choice of correct MRI sequence(s), optimization of the sequence parameters, evaluation of image quality (artifact free and clinically relevant), measurement of geometrical distortion, and evaluation of the accuracy of our offline correction algorithm. Results: CT images showed a maximum deviation of 1.3 mm and minimum deviation of 0.4 mm from true fiducial position for SRS coordinate definition. Interestingly, uncorrected MR images showed maximum deviation of 1.2 mm and minimum of 0.4 mm, comparable to CT images used for SRS coordinate definition. After geometrical correction, we observed a maximum deviation of 1.1 mm and minimum deviation of only 0.3 mm. Conclusion: Our optimized MRI pulse sequences and image correction technique show promising results; MR images produced under these conditions are appropriate for direct use in SRS treatment planning. Published by Elsevier Sp. z o.o. on behalf of Greater Poland Cancer Centre.
引用
收藏
页码:12 / 19
页数:8
相关论文
共 50 条
  • [21] Dosimetric evaluation of MRI-based treatment planning for prostate cancer
    Chen, L
    Price, RA
    Nguyen, TB
    Wang, L
    Li, JS
    Qin, L
    Ding, M
    Palacio, E
    Ma, CM
    Pollack, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (22): : 5157 - 5170
  • [22] MRI-based treatment planning for glioblastoma (GBM): Dosimetric validation
    Chen, L.
    Xu, X.
    Zhu, J.
    Chen, Z.
    Richardson, T.
    Feigenberg, S.
    Wang, L.
    Price, R.
    Ma, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2473 - 2473
  • [23] An overview on MRI-based treatment planning for brachytherapy of cervical cancer
    Kirisits, C
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S4 - S5
  • [24] MRI-Based Treatment Planning for Liver Photon and Proton Radiotherapy
    Liu, Y.
    Lei, Y.
    Wang, T.
    Wang, Y.
    Kayode, O.
    Tian, S.
    Lin, L.
    Liu, T.
    Patel, P.
    Curran, W.
    Zhou, J.
    Ren, L.
    Yang, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E318 - E319
  • [25] MRI-Based Proton Treatment Planning for Base of Skull Tumors
    Shafai-Erfani, Ghazal
    Lei, Yang
    Liu, Yingzi
    Wang, Yinan
    Wang, Tonghe
    Zhong, Jim
    Liu, Tian
    McDonald, Mark
    Curran, Walter J.
    Zhou, Jun
    Shu, Hui-Kuo
    Yang, Xiaofeng
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2019, 6 (02): : 12 - 25
  • [26] MRI Based Treatment Planning of Spinal Stereotactic Radiation Therapy
    Teruel, J. R.
    Wang, H.
    McCarthy, A.
    Osterman, K. S.
    Schiff, P. B.
    Chandarana, H.
    Das, I. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E547 - E548
  • [27] Geometric inaccuracy and co-registration errors for CT, DynaCT and MRI images used in robotic stereotactic radiosurgery treatment planning
    Aldosary, Ghada
    Szanto, Janos
    Holmes, Oliver
    Lavigne, Bernie
    Althobaity, Waleed
    Sheikh, Adnan
    Foottit, Claire
    Vandervoort, Eric
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 212 - 222
  • [28] Geometric Analysis of Target Volume Definition Using Corrected MRI Images and Analysis of Their Use fir Stereotactic Radiosurgery Treatment Planning
    Fatemi, A.
    Khosravi, H.
    Taghizadeh, S.
    Yang, C.
    Morris, B.
    Duggar, W.
    Dios, R. Rey
    Florez, E.
    Vijayakumar, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E544 - E544
  • [29] Assessment of MRI-Based Attenuation Correction for MRI-Only Radiotherapy Treatment Planning of the Brain
    Ranta, Iiro
    Teuho, Jarmo
    Linden, Jani
    Klen, Riku
    Teras, Mika
    Kapanen, Mika
    Keyrilainen, Jani
    DIAGNOSTICS, 2020, 10 (05)
  • [30] MRI-based polymer gel dosimetry for validating plans with multiple matrices in Gamma Knife stereotactic radiosurgery
    Gopishankar, N.
    Watanabe, Yoichi
    Subbiah, Vivekanandhan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02): : 133 - 145