An improved capillary isoelectric focusing-mass spectrometry method for high-resolution characterization of monoclonal antibody charge variants

被引:24
|
作者
Xu, Tian [1 ]
Han, Linjie [2 ]
Thompson, Alayna M. George [2 ]
Sun, Liangliang [1 ]
机构
[1] Michigan State Univ, Dept Chem, 578 S Shaw Lane, E Lansing, MI 48824 USA
[2] AbbVie Inc, Analyt R&D, New Biol Ent NBE, 1 Waukegan Rd, N Chicago, IL 60064 USA
关键词
ZONE-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; ONLINE; INTERFACE; SEPARATION; ESI; MS;
D O I
10.1039/d1ay01556g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Routine and high-resolution characterization of monoclonal antibody (mAb) charge variants is vital for controlling mAb quality as therapeutics. Capillary isoelectric focusing-mass spectrometry (cIEF-MS) has emerged as a powerful tool for characterizing mAb charge variants because it can achieve high-resolution separation and highly sensitive detection of proteins. It provides much better identification of charge variants than the traditionally used cIEF-UV method. However, further improvement of cIEF-MS regarding stability and separation resolution is needed. Here, we improved the stability and enhanced separation resolution of automated cIEF-MS by bettering the quality of capillary neutral coating, reducing catholyte pH to 10 for cIEF-MS for the first time, and systematically optimizing the cIEF separation conditions. The improved cIEF-MS method was applied to characterize charge variants of three previously well characterized mAbs (NISTmAb, cetuximab, trastuzumab) and one tool mAb (mAb1). The charge variants of the studied mAbs were well resolved, and the majority of post-translational modifications (PTMs) found in those mAbs agreed with the literature. cIEF-MS analyses of mAb1 were capable of discovering ten charge variants with various interesting PTMs, such as PGK amidation, incomplete C-terminal lysine clipping, glycosylation, and deamination. cIEF-MS was successfully used for accurately determining the isoelectric points (pIs) of mAb1 charge variants via analyzing the pI markers and spiking in a standard protein (cytochrome c) to samples for migration time normalization, which is beneficial for evaluating pI-related pharmacokinetic properties. Our cIEF-MS agreed with and, in some cases (i.e., cetuximab and mAb1), outperformed cIEF-UV for detecting mAb charge variants.
引用
收藏
页码:383 / 393
页数:12
相关论文
共 50 条
  • [21] Characterization and monitoring of charge variants of a recombinant monoclonal antibody using microfluidic capillary electrophoresis-mass spectrometry
    Sun, Qiang
    Wang, Liang
    Li, Na
    Shi, Liming
    ANALYTICAL BIOCHEMISTRY, 2021, 625
  • [22] Quality assurance of monoclonal antibody pharmaceuticals based on their charge variants using microchip isoelectric focusing method
    Kinoshita, Mitsuhiro
    Nakatsuji, Yuki
    Suzuki, Shigeo
    Hayakawa, Takao
    Kakehi, Kazuaki
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1309 : 76 - 83
  • [23] Characterization of recombinant monoclonal antibody variants detected by hydrophobic interaction chromatography and imaged capillary isoelectric focusing electrophoresis
    King, Cory
    Patel, Rekha
    Ponniah, Gomathinayagam
    Nowak, Christine
    Neill, Alyssa
    Gu, Zhenyu
    Liu, Hongcheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1085 : 96 - 103
  • [24] Cutting-edge mass spectrometry strategy based on imaged capillary isoelectric focusing (icIEF) technology for characterizing charge heterogeneity of monoclonal antibody
    Zhang, Xiaoxi
    Chen, Tong
    Li, Victor
    Bo, Tao
    Du, Min
    Huang, Tiemin
    ANALYTICAL BIOCHEMISTRY, 2023, 660
  • [25] High Resolution Capillary Isoelectric Focusing Mass Spectrometry Analysis of Peptides, Proteins, And Monoclonal Antibodies with a Flow-through Microvial Interface
    Wang, Lingyu
    Bo, Tao
    Zhang, Zhengxiang
    Wang, Guanbo
    Tong, Wenjun
    Chen, David Da Yong
    ANALYTICAL CHEMISTRY, 2018, 90 (15) : 9495 - 9503
  • [26] Deciphering nanoparticle protein coronas by capillary isoelectric focusing-mass spectrometry-based top-down proteomics
    Zhu, Guijie
    Sadeghi, Seyed Amirhossein
    Mahmoudi, Morteza
    Sun, Liangliang
    CHEMICAL COMMUNICATIONS, 2024, 60 (81) : 11528 - 11531
  • [27] In-depth size and charge variants characterization of monoclonal antibody with native mass spectrometry
    Dai, Jun
    Ji, Chengjie
    ANALYTICA CHIMICA ACTA, 2023, 1265
  • [28] High resolution analysis of protein phosphorylation using capillary isoelectric focusing electrospray ionization mass spectrometry
    Wei, J
    Yang, LY
    Harrata, AK
    Lee, CS
    ELECTROPHORESIS, 1998, 19 (13) : 2356 - 2360
  • [29] Separation and detection of intact noncovalent protein complexes from mixtures by on-line capillary isoelectric focusing-mass spectrometry
    Martinovic, S
    Berger, SJ
    Pasa-Tolic, L
    Smith, RD
    ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5356 - 5360
  • [30] Chemical Mobilization-Based Capillary Isoelectric Focusing-Mass Spectrometry Using the nanoCEasy Interface for Pharmaceutical Protein Analysis
    Naghdi, Elahe
    Reinau, Marika Ejby
    Krogh, Thomas Nylandsted
    Neususs, Christian
    ANALYTICAL CHEMISTRY, 2024, 96 (31) : 12827 - 12837