An improved capillary isoelectric focusing-mass spectrometry method for high-resolution characterization of monoclonal antibody charge variants

被引:24
|
作者
Xu, Tian [1 ]
Han, Linjie [2 ]
Thompson, Alayna M. George [2 ]
Sun, Liangliang [1 ]
机构
[1] Michigan State Univ, Dept Chem, 578 S Shaw Lane, E Lansing, MI 48824 USA
[2] AbbVie Inc, Analyt R&D, New Biol Ent NBE, 1 Waukegan Rd, N Chicago, IL 60064 USA
关键词
ZONE-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; ONLINE; INTERFACE; SEPARATION; ESI; MS;
D O I
10.1039/d1ay01556g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Routine and high-resolution characterization of monoclonal antibody (mAb) charge variants is vital for controlling mAb quality as therapeutics. Capillary isoelectric focusing-mass spectrometry (cIEF-MS) has emerged as a powerful tool for characterizing mAb charge variants because it can achieve high-resolution separation and highly sensitive detection of proteins. It provides much better identification of charge variants than the traditionally used cIEF-UV method. However, further improvement of cIEF-MS regarding stability and separation resolution is needed. Here, we improved the stability and enhanced separation resolution of automated cIEF-MS by bettering the quality of capillary neutral coating, reducing catholyte pH to 10 for cIEF-MS for the first time, and systematically optimizing the cIEF separation conditions. The improved cIEF-MS method was applied to characterize charge variants of three previously well characterized mAbs (NISTmAb, cetuximab, trastuzumab) and one tool mAb (mAb1). The charge variants of the studied mAbs were well resolved, and the majority of post-translational modifications (PTMs) found in those mAbs agreed with the literature. cIEF-MS analyses of mAb1 were capable of discovering ten charge variants with various interesting PTMs, such as PGK amidation, incomplete C-terminal lysine clipping, glycosylation, and deamination. cIEF-MS was successfully used for accurately determining the isoelectric points (pIs) of mAb1 charge variants via analyzing the pI markers and spiking in a standard protein (cytochrome c) to samples for migration time normalization, which is beneficial for evaluating pI-related pharmacokinetic properties. Our cIEF-MS agreed with and, in some cases (i.e., cetuximab and mAb1), outperformed cIEF-UV for detecting mAb charge variants.
引用
收藏
页码:383 / 393
页数:12
相关论文
共 50 条
  • [1] Capillary Isoelectric Focusing-Mass Spectrometry Method for the Separation and Online Characterization of Intact Monoclonal Antibody Charge Variants
    Dai, Jun
    Lamp, Jared
    Xia, Qiangwei
    Zhang, Yingru
    ANALYTICAL CHEMISTRY, 2018, 90 (03) : 2246 - 2254
  • [2] A high-resolution capillary isoelectric focusing method for the determination of therapeutic recombinant monoclonal antibody
    Lin, Jun
    Tan, Qingqiao
    Wang, Shaoxiong
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (14) : 1696 - 1702
  • [3] Characterization of human alcohol dehydrogenase isoenzymes by capillary isoelectric focusing-mass spectrometry
    Martinovic, S
    Pasa-Tolic, L
    Masselon, C
    Jensen, PK
    Stone, CL
    Smith, RD
    ELECTROPHORESIS, 2000, 21 (12) : 2368 - 2375
  • [4] Capillary isoelectric focusing-mass spectrometry: Coupling strategies and applications
    Huehner, Jens
    Laemmerhofer, Michael
    Neusuess, Christian
    ELECTROPHORESIS, 2015, 36 (21) : 2670 - 2686
  • [5] Capillary isoelectric focusing-mass spectrometry for shotgun approach in proteomics
    Storms, HF
    van der Heijden, R
    Tjaden, UR
    van der Greef, J
    ELECTROPHORESIS, 2004, 25 (20) : 3461 - 3467
  • [6] High-resolution capillary isoelectric focusing-electrospray ionization mass spectrometry for hemoglobin variants analysis
    Tang, Q
    Harrata, AK
    Lee, CS
    ANALYTICAL CHEMISTRY, 1996, 68 (15) : 2482 - 2487
  • [7] Automated Capillary Isoelectric Focusing-Mass Spectrometry with Ultrahigh Resolution for Characterizing Microheterogeneity and Isoelectric Points of Intact Protein Complexes
    Xu, Tian
    Han, Linjie
    Sun, Liangliang
    ANALYTICAL CHEMISTRY, 2022, 94 (27) : 9674 - 9682
  • [8] Isolation and Characterization of Monoclonal Antibody Charge Variants by Free Flow Isoelectric Focusing
    Hosken, Brian D.
    Li, Charlene
    Mullappally, Berny
    Co, Carl
    Zhang, Boyan
    ANALYTICAL CHEMISTRY, 2016, 88 (11) : 5662 - 5669
  • [9] On-line capillary isoelectric focusing-mass spectrometry for quantitative analysis of peptides and proteins
    Kuroda, Y
    Yukinaga, H
    Kitano, M
    Noguchi, T
    Nemati, M
    Shibukawa, A
    Nakagawa, T
    Matsuzaki, K
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (03) : 423 - 428
  • [10] Charge Variants Analysis of a Bispecific Antibody Using a Fully Automated One-step Capillary Isoelectric Focusing - Mass Spectrometry Method
    Wu, Gang
    Yu, Chuanfei
    Wang, Wenbo
    Du, Jialiang
    Xu, Gangling
    Fu, Zhihao
    Wang, Lan
    CURRENT PHARMACEUTICAL ANALYSIS, 2022, 18 (09) : 860 - 870