Quantification of dosimetric impact of implementation of on-board imaging (OBI) for imrt treatment of head-and-neck malignancies

被引:8
|
作者
Lawsonm, Joshua D. [1 ]
Elder, Eric [1 ]
Fox, Tim [1 ]
Davis, Lawrence [1 ]
Crocker, Ian [1 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Winship Canc Ctr, Atlanta, GA 30322 USA
关键词
on-board Imaging (OBI); interfraction motion management; head-and-neck malignancies; image-guided radiation; therapy (IGRT);
D O I
10.1016/j.meddos.2007.02.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Implementation of daily kilovoltage imaging for setup verification improves the reproducibility of treatment by eliminating small random setup errors. We evaluate the dosimetric consequences of such shifts, not yet evaluated, in a group of head-and-neck cancer patients (ENT) treated with intensity modulated radiation therapy (IMRT) at Emory University. Twelve patients with ENT malignancies were analyzed. On-Board Imaging (OBI) was used in at least 70% of each patient's treatment sessions. An isodose distribution was generated for each fraction, with the isocenter shifted to its calculated location prior to OBI repositioning. These plans were summed and then compared to the simulation plan for coverage of target structures. For these 12 patients, there were a total of 18 planning target volumes (PTV). The mean (range) percent reduction in minimum dose was 12.1% (-1.0 to 43.3). For 10 right necks and 9 left necks treated, the mean percent reduction in minimum dose was 11.8% (-0.6 to 39.7) and 13.3% (-3.6 to 31.2), respectively. The mean reduction in mean dose to the PTV was 1.3% (0 to 5.1). The mean reduction in mean dose to the right and left necks was 1.0% (0.2 to 3.9) and 1.13% (0.4 to 3.4), respectively. From this analysis, we conclude that the shifts made were small and random, with essentially no change in mean dose delivered to target structures. There is, however, significant improvement in the minimum dose delivered. Underdosing even a small portion of the tumor potentially sacrifices the probability of local control; correcting these setup errors seems desirable. (C) 2007 American Association of Medical Dosimetrists.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 50 条
  • [1] LINAC-based on-board imaging feasibility and the dosimetric consequences of head roll in head-and-neck IMRT plans
    Kim, Gwe-Ya
    Pawlicki, Todd
    Le, Quynh-Thu
    Luxton, Gary
    [J]. MEDICAL DOSIMETRY, 2008, 33 (01) : 93 - 99
  • [2] Implementation of on-board imaging (OBI) and quantification of resultant patient shifts
    Lawson, J
    Fox, T
    Elder, E
    Davis, L
    Keller, J
    Crocker, I
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S528 - S528
  • [3] IMRT/VMAT for malignancies in the head-and-neck region
    Brown, Michelle L.
    Glanzmann, Christoph
    Huber, Gerhard
    Bredell, Marius
    Rordorf, Tamara
    Studer, Gabriela
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (08) : 526 - 536
  • [4] The Dosimetric/Clinical Impact on Parotids of Weight Change During Head-and-Neck IMRT
    Charpentier, A.
    Aubry, J.
    Fortin, B.
    Coulombe, G.
    Lambert, L.
    Nguyen-Tan, P.
    Filion, E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S476 - S477
  • [5] IMRT with compensators for head-and-neck cancers - Treatment technique, dosimetric accuracy, and practical experiences
    Salz, H
    Wiezorek, T
    Scheithauer, M
    Schwedas, M
    Beck, J
    Wendt, TG
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2005, 181 (10) : 665 - 672
  • [6] Clinical implementation of on-board CBCT-based adaptive IMRT for head and neck cancer
    Xing, L.
    Lee, L.
    Chao, M.
    Keall, P.
    La, T.
    Le, Q.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S446 - S446
  • [7] DOSIMETRIC EVALUATION OF AUTOMATIC SEGMENTATION FOR ADAPTIVE IMRT FOR HEAD-AND-NECK CANCER
    Tsuji, Stuart Y.
    Hwang, Andrew
    Weinberg, Vivian
    Yom, Sue S.
    Quivey, Jeanne M.
    Xia, Ping
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (03): : 707 - 714
  • [8] Dosimetric Impact of Contour Variation in Head-and-Neck Anatomy
    Lim, T. Y.
    Gillespie, E. F.
    Li, N.
    Ziemer, B.
    Sherer, M.
    Murphy, J. D.
    Moore, K. L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E353 - E353
  • [9] Comparison of head and neck IMRT setup accuracy and reproducibility using different on-board imaging systems
    Dogan, N.
    Shumadine, J.
    Saleh, H.
    Song, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S595 - S595
  • [10] Dosimetric impact of the 160 MLC on head and neck IMRT treatments
    Rassiah-Szegedi, Prema
    Szegedi, Martin
    Sarkar, Vikren
    Streitmatter, Seth
    Huang, Y. Jessica
    Zhao, Hui
    Salter, Bill
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (06): : 73 - 80