Quantification of dosimetric impact of implementation of on-board imaging (OBI) for imrt treatment of head-and-neck malignancies

被引:8
|
作者
Lawsonm, Joshua D. [1 ]
Elder, Eric [1 ]
Fox, Tim [1 ]
Davis, Lawrence [1 ]
Crocker, Ian [1 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Winship Canc Ctr, Atlanta, GA 30322 USA
关键词
on-board Imaging (OBI); interfraction motion management; head-and-neck malignancies; image-guided radiation; therapy (IGRT);
D O I
10.1016/j.meddos.2007.02.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Implementation of daily kilovoltage imaging for setup verification improves the reproducibility of treatment by eliminating small random setup errors. We evaluate the dosimetric consequences of such shifts, not yet evaluated, in a group of head-and-neck cancer patients (ENT) treated with intensity modulated radiation therapy (IMRT) at Emory University. Twelve patients with ENT malignancies were analyzed. On-Board Imaging (OBI) was used in at least 70% of each patient's treatment sessions. An isodose distribution was generated for each fraction, with the isocenter shifted to its calculated location prior to OBI repositioning. These plans were summed and then compared to the simulation plan for coverage of target structures. For these 12 patients, there were a total of 18 planning target volumes (PTV). The mean (range) percent reduction in minimum dose was 12.1% (-1.0 to 43.3). For 10 right necks and 9 left necks treated, the mean percent reduction in minimum dose was 11.8% (-0.6 to 39.7) and 13.3% (-3.6 to 31.2), respectively. The mean reduction in mean dose to the PTV was 1.3% (0 to 5.1). The mean reduction in mean dose to the right and left necks was 1.0% (0.2 to 3.9) and 1.13% (0.4 to 3.4), respectively. From this analysis, we conclude that the shifts made were small and random, with essentially no change in mean dose delivered to target structures. There is, however, significant improvement in the minimum dose delivered. Underdosing even a small portion of the tumor potentially sacrifices the probability of local control; correcting these setup errors seems desirable. (C) 2007 American Association of Medical Dosimetrists.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 50 条
  • [41] Target equivalent uniform dose as a quality indicator for head-and-neck IMRT treatment plans
    Constantinescu, C.
    Al-Wassia, R.
    Al-Hebshi, A.
    Bahadur, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S214 - S215
  • [42] Analysis of Dosimetric Errors for CBCT Based Dose Calculation for IMRT Head and Neck Treatment
    Li, J.
    Chan, M.
    Burman, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [43] Dosimetric Accuracy of Bulk Density Assignment on MRI for Head and Neck IMRT Treatment Planning
    Teo, B.
    Chin, A. L.
    Lin, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S15 - S15
  • [44] Dosimetric Impact of Dental Amalgam CT Image Artifacts On IMRT and VMAT Head and Neck Plans
    Cao, N.
    Young, L.
    Parvathaneni, U.
    Liao, J.
    Richard, P.
    Ford, E.
    Sandison, G.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 308 - 308
  • [45] Dosimetric Impact of Anatomy Variations and Benefits of Mid-Course Replanning for Head and Neck IMRT
    Lindsay, P.
    Yildirim, G.
    Garden, A.
    Zhang, L.
    Yu, Z.
    Zhang, Y.
    Zhu, X.
    Theriot, L.
    Ahamad, A.
    Dong, L.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [46] mARC vs. IMRT treatment of prostate and head-and-neck cancer with flat and FFF energies
    Dzierma, Y.
    Bell, K.
    Nuesken, F.
    Palm, J.
    Fleckenstein, J.
    Licht, N.
    Ruebe, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S781 - S781
  • [47] IMRT treatment plan dosimetry as a predictor for loco-regional control in head-and-neck cancer
    Constantinescu, C.
    Al-Wassia, R.
    Bahadur, Y.
    Awad, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S618 - S619
  • [48] Does interfraction error in head & neck cancer patients treated by IMRT need correction-Indian experience using on-board imaging device
    Bansal, V.
    Shankar, V.
    Bhavsar, D.
    Kumar, A.
    Subramanian, V. S.
    Gajjar, S.
    Patel, V.
    Patel, R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S445 - S446
  • [49] A Dosimetric Comparison of Pharyngeal Constrictor Segmentation Methods During Radiation Treatment for Head-and-Neck Cancer
    Awan, M.
    Rosenthal, D. I.
    Baron, C. A.
    Nuanjing, C.
    Holmes, M. K.
    Fuller, C. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S585 - S585
  • [50] Impact of dysphagia on quality of life after treatment of head-and-neck cancer
    Nguyen, NP
    Frank, C
    Moltz, CC
    Vos, P
    Smith, HJ
    Karlsson, U
    Dutta, S
    Midyett, A
    Barloon, J
    Sallah, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03): : 772 - 778