Effect of round-edged acrylic intraocular lenses on preventing posterior capsule opacification

被引:114
|
作者
Nishi, O
Nishi, K
Akura, J
Nagata, T
机构
[1] Nishi Eye Hosp, Higashinari Ku, Osaka 5370025, Japan
[2] Kushimoto Rehabil Ctr, Wakayama, Japan
[3] Hamamatsu Univ Sch Med, Dept Ophthalmol, Hamamatsu, Shizuoka, Japan
来源
关键词
D O I
10.1016/S0886-3350(00)00644-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To clarify the extent to which the adhesiveness of an acrylic material influences the formation of posterior capsule opacification (PCO). Setting: Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. Methods: Two types of AcrySof (R) intraocular lenses (IOLs) were prepared: round edged and tumbled. The AcrySOf With round edges was implanted in 1 eye in a group of ii rabbits and the tumbled IOL in 1 eye in a group of 5 rabbits, In both groups, the contralateral eye received a conventional AcrySof with sharp optic edges. A histopathological examination was,performed 3 weeks after surgery. Results: With the round-edged AcrySof IOL, no capsular bend formed at the optic edge and abundant lens epithelial cells (LECs) migrated posteriorly. With the sharp-edged AcrySof lens, a sharp capsular bend formed and LEC migration was significantly inhibited. In eyes with a tumbled IOL, a capsular bend was created, but it was less marked than that created by the sharp-edged lens and there was slightly more LEC migration posteriorly. Conclusions: The AcrySof IOL lost its preventive effect on PCO when the optic was rounded. The effect of the AcrySof lens in preventing PCO is mainly a result of its rectangular, sharp-edged optic design. The acrylic material may play a complementary role by helping create a sharp capsular bend. Capsular bend formation is the key to the PCO preventive effect of an IOL.
引用
收藏
页码:608 / 613
页数:6
相关论文
共 50 条
  • [11] Relationship of AcrySof acrylic and PhacoFlex silicone intraocular lenses to visual acuity and posterior capsule opacification
    Halpern, MT
    Covert, D
    Battista, C
    Weinstein, AJ
    Levinson, RD
    Yan, L
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04): : 662 - 669
  • [12] Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification
    Buehl, W
    Findl, O
    Menapace, R
    Rainer, G
    Sacu, S
    Kiss, B
    Petternel, V
    Georgopoulos, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07): : 1105 - 1111
  • [13] Analysis of cytoskeletal proteins in posterior capsule opacification after implantation of acrylic and hydrogel intraocular lenses
    Matsushima, H
    Mukai, K
    Obara, Y
    Yoshida, S
    Clark, JI
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (01): : 187 - 194
  • [14] Hydrophobic versus double-square-edged hydrophilic foldable acrylic intraocular lens: Effect on posterior capsule opacification
    Iwase, Takeshi
    Nishi, Yutarou
    Oveson, Brian C.
    Jo, Young-Joon
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1060 - 1068
  • [15] Posterior capsule opacification after phacoemulsification:: Foldable acrylic versus poly(methyl methacrylate) intraocular lenses
    Oner, FH
    Gunenc, Ü
    Ferliel, ST
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (05): : 722 - 726
  • [16] Posterior capsule opacification in acrylic versus PMMA intraocular lenses in resident performed cataract surgery.
    Al-Aswad, LA
    Elkin, N
    Laudi, JJ
    Smith, EF
    Schrier, A
    Gombos, G
    Fingeret, M
    Edelstein, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S285 - S285
  • [17] Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge
    Werner, L
    Mamalis, N
    Pandey, SK
    Izak, AM
    Nilson, CD
    Davis, BL
    Weight, C
    Apple, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11): : 2403 - 2409
  • [18] The effectiveness of Nd:YAG laser capsulotomy for the treatment of posterior capsule opacification in children with acrylic intraocular lenses
    Stager, DR
    Wang, XH
    Weakley, DR
    Felius, J
    JOURNAL OF AAPOS, 2006, 10 (02): : 159 - 163
  • [19] Randomized multicenter trial to assess posterior capsule opacification and glistenings in two hydrophobic acrylic intraocular lenses
    Gerd U. Auffarth
    Antoine Brézin
    François Lignereux
    Ramin Khoramnia
    Timur M. Yildirim
    Thomas Kohnen
    Jessica Bianco
    Scientific Reports, 13
  • [20] Randomized multicenter trial to assess posterior capsule opacification and glistenings in two hydrophobic acrylic intraocular lenses
    Auffarth, Gerd U.
    Brezin, Antoine
    Lignereux, Francois
    Khoramnia, Ramin
    Yildirim, Timur M.
    Kohnen, Thomas
    Bianco, Jessica
    SCIENTIFIC REPORTS, 2023, 13 (01)