摘要
To evaluate the long-term posterior capsule opacification (PCO) formation, and glistening rate of the HOYA Vivinex (XY1) IOL compared to Alcon AcrySof (SN60WF). In this prospective, multicentric, randomized, paired-eye, open-label study, we included 87 subjects that underwent cataract surgery with IOL implantation, with 67 patients completing the 3-year follow-up. The completer population consisted of 32 subjects implanted with XY1 and 35 implanted with SN60WF. Primary endpoints consisted of the evaluation of glistenings and measurement of PCO. Secondary outcomes included Best Corrected Distance Visual Acuity (BCVA), Contrast Acuity (CA), uncorrected visual acuities, subjective refraction, medical and lens complication rates, adverse events, and optical/visual symptoms. Follow-up visits occurred at 6-months, 1-, 2- and 3-years. At 3-years follow-up, mean PCO score was 0.121 +/- 0.193 for eyes implanted with Vivinex versus 0.239 +/- 0.463 for AcrySof (p = 0.026). The Vivinex IOL showed statistically significantly lower glistening occurrence through 3-years postoperatively (0.14 +/- 0.26) compared to AcrySof (1.79 +/- 1.43; p < 0.0001). Postoperative visual acuities improved from baseline in both IOL groups (p < 0.0001), and remained stable through the 3-year follow-up period. Eyes implanted with a HOYA Vivinex IOL exhibited significantly lower occurrence of glistening at 3-years versus Alcon AcrySof (p < 0.0001). Incidence of PCO was very low and comparable in both Vivinex and AcrySof eyes.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Randomized multicenter trial to assess posterior capsule opacification and glistenings in two hydrophobic acrylic intraocular lenses
    Gerd U. Auffarth
    Antoine Brézin
    François Lignereux
    Ramin Khoramnia
    Timur M. Yildirim
    Thomas Kohnen
    Jessica Bianco
    Scientific Reports, 13
  • [2] Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial
    Leydolt, Christina
    Schartmuller, Daniel
    Schwarzenbacher, Luca
    Roggla, Veronika
    Schriefl, Sabine
    Menapace, Rupert
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 217 : 224 - 231
  • [3] Comment on: Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial
    Tuuminen, Raimo
    Belda, Jose I.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 223 : 447 - 449
  • [4] Comparison of posterior capsule opacification with hydrophobic acrylic and hydrophilic acrylic intraocular lenses
    Vasavada, Abhay R.
    Raj, Shetal M.
    Shah, Alpesh
    Shah, Gauri
    Vasavada, Viraj
    Vasavada, Vaishali
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1050 - 1059
  • [5] Reply to Comment on: Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial
    Leydolt, Christina
    Menapace, Rupert
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 223 : 449 - 450
  • [6] Comparison of posterior capsule opacification and glistenings with 2 hydrophobic acrylic intraocular lenses: 5-to 7-year follow-up
    Chang, Anthony
    Behndig, Anders
    Ronbeck, Margrethe
    Kugelberg, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05): : 694 - 698
  • [7] The Effect of Single-Piece Hydrophobic Acrylic Intraocular Lenses on the Development of Posterior Capsule Opacification
    Praveen, Mamidipudi R.
    Shah, Gauri D.
    Vasavada, Abhay R.
    Dave, Khyati H.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (03) : 470 - 478
  • [8] Glistenings in a large series of hydrophobic acrylic intraocular lenses
    Colin, Joseph
    Orignac, Isabelle
    Touboul, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2121 - 2126
  • [9] Active oxygen processing for acrylic intraocular lenses to prevent posterior capsule opacification
    Matsushima, Hiroyuki
    Iwamoto, Hidetoshi
    Mukai, Kouichiro
    Obara, Yoshitaka
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06): : 1035 - 1040
  • [10] Comparison of posterior capsule opacification rates between hydrophilic and hydrophobic single-viece acrylic intraocular lenses
    Heatley, CJ
    Spalton, DJ
    Kumar, A
    Jose, R
    Boyce, J
    Bender, LE
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04): : 718 - 724