PET, CT, and MR image registration of the rat brain and skull

被引:38
|
作者
Vaquero, JJ
Desco, M
Pascau, J
Santos, A
Lee, I
Seidel, J
Green, MV
机构
[1] NIH, Bethesda, MD 20892 USA
[2] Univ Madrid, Hosp Gen Gregorio Maranon, Madrid 3, Spain
[3] Univ Politecn Madrid, Madrid, Spain
关键词
image reconstruction; positron emission tomography (PET); small animal imaging;
D O I
10.1109/23.958376
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spatially registered positron emission tomography (PET), computed tomography (CT), and magnetic resonance (MR) images of the same small animal offer potential advantages over PET alone: CT images should allow accurate, nearly noise-free correction of the PET image data for attenuation; the CT or MR images should permit more certain identification of structures evident in the PET images; and CT images provide a priori anatomical information that may be of use with resolution-improving image-reconstruction algorithms that model the PET imaging process. However, image registration algorithms effective in human studies have not been characterized in the small-animal setting. Accordingly, we evaluated the ability of the automated image registration (AIR) and mutual information (MI) algorithms to register PET images of the rat skull and brain to CT or MR images of the same animal. External fiducial marks visible in all three modalities were used to estimate residual errors after registration. The AIR algorithm registered PET bone-to-CT bone images with a maximum error of less than 1.0 mm. The registration errors for PET brain-to-CT brain images, however, were greater, and considerable user intervention was required prior to registration. The AIR algorithm either failed or required excessive user intervention to register PET and MR brain images. In contrast, the MI algorithm yielded smaller registration errors in all scenarios with little user intervention. The MI algorithm thus appears to be a more robust method for registering PET, CT, and MR images of the rat head.
引用
收藏
页码:1440 / 1445
页数:6
相关论文
共 50 条
  • [31] Efficient Hybrid Registration Method Using a Shell Volume for PET and High Resolution MR Brain Image Fusion
    Lee, Ho
    Lee, Jeongjin
    Kim, Gyehyun
    Shin, Yeong Gil
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 2326 - 2329
  • [32] Three-dimensional MR image registration of the human brain
    Bedell, BJ
    Narayana, PA
    Johnston, DA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) : 384 - 390
  • [33] Image registration accuracy of an in-house developed patient transport system for PET/CT plus MR and SPECT plus CT imaging
    Samarin, Andrei
    Kuhn, Felix P.
    Brandsberg, Fredrik
    von Schulthess, Gustav
    Burger, Irene A.
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (02) : 194 - 200
  • [34] Simultaneous Reconstruction of the Activity Image and Registration of the CT Image in TOF-PET
    Rezaei, Ahmadreza
    Nuyts, Johan
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [35] Simultaneous reconstruction of the activity image and registration of the CT image in TOF-PET
    Rezaei, Ahmadreza
    Michel, Christian
    Casey, Michael E.
    Nuyts, Johan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04): : 1852 - 1874
  • [36] Robust Anatomical Landmark Detection for MR Brain Image Registration
    Han, Dong
    Gao, Yaozong
    Wu, Guorong
    Yap, Pew-Thian
    Shen, Dinggang
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2014, PT I, 2014, 8673 : 186 - +
  • [37] ACCURACY OF REGISTRATION OF PET, SPECT AND MR-IMAGES OF A BRAIN PHANTOM
    TURKINGTON, TG
    JASZCZAK, RJ
    PELIZZARI, CA
    HARRIS, CC
    MACFALL, JR
    HOFFMAN, JM
    COLEMAN, RE
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (09) : 1587 - 1594
  • [38] Automated registration of intraoperative CT image data for navigated skull base surgery
    Eggers, G.
    Kress, B.
    Muehling, J.
    [J]. MINIMALLY INVASIVE NEUROSURGERY, 2008, 51 (01) : 15 - 20
  • [39] Robust surface registration in PET-CT brain images
    Lee, H
    Hong, H
    Shin, YG
    [J]. CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1286 - 1286
  • [40] Automated PET/CT Brain Registration for Accurate Attenuation Correction
    Khurshid, Khawar
    Berger, Kevin L.
    McGough, Robert J.
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5805 - 5808