ACCURACY OF REGISTRATION OF PET, SPECT AND MR-IMAGES OF A BRAIN PHANTOM

被引:0
|
作者
TURKINGTON, TG [1 ]
JASZCZAK, RJ [1 ]
PELIZZARI, CA [1 ]
HARRIS, CC [1 ]
MACFALL, JR [1 ]
HOFFMAN, JM [1 ]
COLEMAN, RE [1 ]
机构
[1] UNIV CHICAGO, DEPT RADIAT ONCOL, CHICAGO, IL 60637 USA
来源
JOURNAL OF NUCLEAR MEDICINE | 1993年 / 34卷 / 09期
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accuracy of a surface-fitting algorithm for three-dimensional image registration of single photon emission computed tomography (SPECT), positron emission tomography (PET), and magnetic resonance (MR) images was tested using a three-dimensional, water-fillable brain phantom. Multislice or volume image sets were acquired for each modality. Small fiducial markers were attached to assess accuracy of surface fitting and provide an alternate fitting technique. A maximum gradient technique was found to work well for SPECT and PET edge detection. Transformation parameters for translation, rotation and scaling were determined by surface fit to match each SPECT and PET scan with MR images. Using the markers, overall translation error's were found to be <2 mm in each direction and rotational errors <2 degrees in every case. Errors for specific internal regions were also determined to be <2 mm for most regions, with only a few fits resulting in errors >3 mm for some cortical regions. Results indicate surface fitting to be sufficiently accurate for visual comparison of registered images and for enhanced SPECT and PET region of interest (ROI) determination and image reconstruction.
引用
收藏
页码:1587 / 1594
页数:8
相关论文
共 50 条
  • [1] FAST NONSUPERVISED 3D REGISTRATION OF PET AND MR-IMAGES OF THE BRAIN
    MANGIN, JF
    FROUIN, V
    BLOCH, I
    BENDRIEM, B
    LOPEZKRAHE, J
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1994, 14 (05): : 749 - 762
  • [2] SPATIAL AND TEMPORAL REGISTRATION OF CARDIAC SPECT AND MR-IMAGES - METHODS AND EVALUATION
    FABER, TL
    MCCOLL, RW
    OPPERMAN, RM
    CORBETT, JR
    PESHOCK, RM
    [J]. RADIOLOGY, 1991, 179 (03) : 857 - 861
  • [3] Fast registration technique of MR and SPECT brain images
    Sun, YN
    Huang, SC
    Chang, TC
    Chen, FJ
    Chiu, NT
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 1442 - 1449
  • [4] POINT LANDMARKS FOR REGISTRATION OF CT AND MR-IMAGES
    BANERJEE, S
    MUKHERJEE, DP
    MAJUMDAR, DD
    [J]. PATTERN RECOGNITION LETTERS, 1995, 16 (10) : 1033 - 1042
  • [5] REGISTRATION OF TL-201 SPECT AND PET IMAGES WITH MR IMAGES IN PATIENTS WITH PRIMARY BRAIN-TUMORS
    MACAPINLAC, HA
    SCOTT, AM
    ZHANG, J
    KALAIGIAN, H
    CALUSER, CI
    DELAPAZ, RL
    [J]. RADIOLOGY, 1992, 185 : 234 - 234
  • [6] ACCURACY OF SURFACE FIT REGISTRATION FOR PET AND MR BRAIN IMAGES USING FULL AND INCOMPLETE BRAIN SURFACES
    TURKINGTON, TG
    HOFFMAN, JM
    JASZCZAK, RJ
    MACFALL, JR
    HARRIS, CC
    KILTS, CD
    PELIZZARI, CA
    COLEMAN, RE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (01) : 117 - 124
  • [7] Integrated registration and visualization of MR and PET brain images
    Hong, H
    Kye, H
    Shin, YG
    [J]. MEDICAL IMAGING 2004: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2004, 5367 : 617 - 627
  • [8] Registration of SPECT and MR brain images using a fuzzy surface
    Maintz, JBA
    vandenElsen, PA
    Viergever, MA
    [J]. MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 : 821 - 829
  • [9] THE ACCURACY OF SPECT BRAIN ACTIVATION IMAGES - PROPAGATION OF REGISTRATION ERRORS
    SYCHRA, JJ
    PAVEL, DG
    CHEN, Y
    JANI, A
    [J]. MEDICAL PHYSICS, 1994, 21 (10) : 1585 - 1590
  • [10] THE ACCURACY OF SPECT BRAIN ACTIVATION IMAGES - PROPAGATION OF REGISTRATION ERRORS
    SYCHRA, JJ
    PAVEL, DG
    CHEN, Y
    JANI, A
    [J]. MEDICAL PHYSICS, 1994, 21 (12) : 1927 - 1932