Region-of-interest cone beam computed tomography (ROI CBCT) with a high resolution CMOS detector

被引:6
|
作者
Jain, A. [1 ]
Takemoto, H. [2 ]
Silver, M. D. [2 ]
Nagesh, S. V. S. [1 ]
Ionita, C. N. [1 ]
Bednarek, D. R. [1 ]
Rudin, S. [1 ]
机构
[1] SUNY Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY 14260 USA
[2] Toshiba Med Res Inst, Vernon Hills, IL USA
关键词
ROTATIONAL ANGIOGRAPHY; RECONSTRUCTION; SYSTEM;
D O I
10.1117/12.2081450
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cone beam computed tomography (CBCT) systems with rotational gantries that have standard flat panel detectors (FPD) are widely used for the 3D rendering of vascular structures using Feldkamp cone beam reconstruction algorithms. One of the inherent limitations of these systems is limited resolution (<3 lp/mm). There are systems available with higher resolution but their small FOV limits them to small animal imaging only. In this work, we report on region-of-interest (ROI) CBCT with a high resolution CMOS detector (75 mu m pixels, 600 mu m HR-CsI) mounted with motorized detector changer on a commercial FPD-based C-arm angiography gantry (194 mu m pixels, 600 mu m HL-CsI). A cylindrical CT phantom and neuro stents were imaged with both detectors. For each detector a total of 209 images were acquired in a rotational protocol. The technique parameters chosen for the FPD by the imaging system were used for the CMOS detector. The anti-scatter grid was removed and the incident scatter was kept the same for both detectors with identical collimator settings. The FPD images were reconstructed for the 10 cm x10 cm FOV and the CMOS images were reconstructed for a 3.84 cm x 3.84 cm FOV. Although the reconstructed images from the CMOS detector demonstrated comparable contrast to the FPD images, the reconstructed 3D images of the neuro stent clearly showed that the CMOS detector improved delineation of smaller objects such as the stent struts (similar to 70 mu m) compared to the FPD. Further development and the potential for substantial clinical impact are suggested.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [31] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [32] Exact spiral scan region-of-interest cone beam CT via backprojection
    Tam, KC
    Lauritsch, G
    Sourbelle, K
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1593 - 1597
  • [33] 3D ROI imaging for cone-beam computed tomography
    Wiegert, J
    Bertram, M
    Wulff, J
    Schäfer, D
    Weese, R
    Netsch, T
    Schombergc, H
    Rose, G
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 7 - 12
  • [34] Region-of-interest reconstruction for a cone-beam dental CT with a circular trajectory
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Zheng, Hairong
    Xia, Dan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 708 : 39 - 45
  • [35] Clinical High-Resolution Imaging of the Inner Ear by Using Magnetic Resonance Imaging (MRI) and Cone Beam Computed Tomography (CBCT)
    Santek, Tomislav
    Hofmann, Erich
    Milewski, Christian
    Schwager, Konrad
    Prescher, Andreas
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (06):
  • [36] Effect of region-of-interest placement in bolus tracking cerebral computed tomography angiography
    Raymond Y. Huang
    Bob B. Chai
    Thomas C. Lee
    Neuroradiology, 2013, 55 : 1183 - 1188
  • [37] Audiological correlates of cone beam computed tomography (CBCT) in cochlear implant recipients
    Rahman, Tayseer Taha Abdel
    Kader, Hesham Abd El Aty Abdel
    Aziz, Tougan Taha Abdel
    HEARING BALANCE AND COMMUNICATION, 2019, 17 (04) : 249 - 256
  • [38] The Application of Cone Beam Computed Tomography (CBCT) on the Diagnosis and Management of Maxillofacial Trauma
    Rashid, Arif
    Feinberg, Lee
    Fan, Kathleen
    DIAGNOSTICS, 2024, 14 (04)
  • [39] Erratum to: Cone Beam Computed Tomography (CBCT) in the Field of Interventional Oncology of the Liver
    Blanche Bapst
    Matthieu Lagadec
    Romain Breguet
    Valérie Vilgrain
    Maxime Ronot
    CardioVascular and Interventional Radiology, 2015, 38 : 1381 - 1381
  • [40] The reliability of cone-beam computed tomography (CBCT) - Generated frontal cephalogramsq
    Kim, So-Jin
    Park, Soo-Byung
    Kim, Yong-Il
    Cho, Bong-Hae
    Hwang, Dae-Seok
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (08) : E331 - E336