Exact spiral scan region-of-interest cone beam CT via backprojection

被引:0
|
作者
Tam, KC [1 ]
Lauritsch, G [1 ]
Sourbelle, K [1 ]
机构
[1] Siemens Corp Res Inc, Princeton, NJ 08540 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a spiral scan cone beam reconstruction algorithm in which image reconstruction proceeds via backprojection in the object space. In principle the algorithm can reconstruct sectional ROI in a long object. The approach is a generalization of the cone beam backprojection technique developed by Kudo and Saito in two aspects: the resource-demanding normalization step in the Kudo and Saito's algorithm is eliminated through the technique of data combination which we published earlier, and the elimination of the restriction that the detector be big enough to capture the entire image of the ROI. Restricting the projection data to the appropriate angular range required by data combination can be accomplished by a masking process. Because of the simplification resulting from the elimination of the normalization step, the most time-consuming operations of the algorithm can be approximated by the efficient step of line-by-line ramp filtering the cone beam image in the direction of the scan path, plus a correction image. The correction image, which can be computed exactly, is needed because data combination is not properly matched at the mask boundary when ramp filtering is involved. Empirical 2D PSF, the Shepp-Logan filter, and a modified ramp filter are developed to improve matching with the correction image which is computed with finite samplings. The use of transition region to further improve matching is introduced. The results of testing the algorithm on simulated phantoms are presented.
引用
收藏
页码:1593 / 1597
页数:5
相关论文
共 50 条
  • [1] Backprojection spiral scan region-of-interest cone beam CT
    Tam, KC
    Ladendorf, B
    Sauer, F
    Lauritsch, G
    Steinmetz, A
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 433 - 441
  • [2] Exact (spiral plus circles) scan region-of-interest cone beam reconstruction via backprojection
    Tam, KC
    Lauritsch, G
    Sourbelle, K
    Sauer, F
    Ladendorf, B
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 376 - 383
  • [3] Region-of-interest cone beam CT with a spiral scan
    Tam, KC
    Samarasekera, S
    Sauer, F
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 274 - 283
  • [4] Exact cone beam CT with a spiral scan
    Tam, KC
    Samarasekera, S
    Sauer, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 1015 - 1024
  • [5] A parallel backprojection algorithm for spiral cone-beam ct exact reconstruction
    Xue G.
    Zhang Y.
    International Journal of Digital Content Technology and its Applications, 2010, 4 (06) : 134 - 143
  • [6] Exact local regions-of-interest reconstruction in spiral cone-beam filtered-backprojection CT: theory
    Tam, KC
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 506 - 519
  • [7] Region-of-Interest Imaging in Cone Beam 3-D CT
    K. C. Tam
    Journal of Nondestructive Evaluation, 1998, 17 : 17 - 26
  • [8] Region-of-interest imaging in cone beam 3-D CT
    Tam, KC
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 1998, 17 (01) : 17 - 26
  • [9] Cone beam cover method: An approach to performing backprojection in Katsevich's exact algorithm for spiral cone beam CT
    Yang, Jiansheng
    Kong, Qiang
    Zhou, Tie
    Jiang, Ming
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (04) : 199 - 214
  • [10] Region-of-interest reconstruction for a cone-beam dental CT with a circular trajectory
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Zheng, Hairong
    Xia, Dan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 708 : 39 - 45