A novel PEG-mediated boric acid functionalized magnetic nanomaterials based fluorescence biosensor for the detection of Staphylococcus aureus

被引:23
|
作者
Wang, Zhengzheng [1 ]
Feng, Xiaoyan [1 ]
Xiao, Fangbin [1 ]
Bai, Xuekun [1 ]
Xu, Qian [1 ]
Xu, Hengyi [1 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, 235 Nanjing East Rd, Nanchang 330047, Jiangxi, Peoples R China
基金
国家重点研发计划;
关键词
Staphylococcus aureus; 3-aminophenylboronic acid; Magnetic separation; Fluorescence; OUTBREAK; GENES;
D O I
10.1016/j.microc.2022.107379
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Staphylococcus aureus (S. aureus) is one of the pathogens that seriously endanger human health and are widespread in nature. Food poisoning incidents caused by S. aureus frequently break out. Therefore, it is significant that a rapid and accurate method is established for S. aureus detection. In this study, a strategy using magnetic separation combine with fluorescence analysis was proposed for S. aureus detection. Boric acid can selectively enrich compounds with cis-diol groups through a reversible esterification reaction, and has been widely used in the identification of sugars and glycosylated molecules. As a boric acid derivative, 3-aminophenylboronic acid (APBA) has the advantages of stability, low cost, easy synthesis, etc. Therefore, using APBA as a recognition molecule to prepare magnetic nanomaterials can achieve the enrichment of S. aureus. In order to reduce steric hindrance and ensure the dominant orientation of APBA, thus improving the enrichment performance of target bacteria. The polyethylene glycol (PEG) was used as a mediator to prepare PEG-mediated APBA functionalized magnetic nanomaterials (APBA-PEG-MNs). In addition, this study used FITC-pig IgG to label S. aureus because the Fc fragment of IgG to bind protein A on the surface of S. aureus and realized the detection of S. aureus by detecting fluorescence. Under the optimal experimental conditions, the capture efficiency of APBA-PEG-MNs for S. aureus with the concentration of 2.7 x 10(6) CFU/mL in spinach, juice and pool water spiked samples was 92.6%, 91.6%, 91.6%. The limit of detection of the strategy in spiked samples was 2.7 x 10(2) CFU/mL within 80 min.
引用
收藏
页数:8
相关论文
共 49 条
  • [31] Lysin cell-binding domain-functionalized magnetic beads for detection of Staphylococcus aureus via inhibition of fluorescence of Amplex Red/hydrogen peroxide assay by intracellular catalase
    Zhengjun Yi
    Shuhui Wang
    Xiangying Meng
    Anqi Wu
    Qian Li
    Yongjie Song
    Ronglan Zhao
    Jinjuan Qiao
    Analytical and Bioanalytical Chemistry, 2019, 411 : 7177 - 7185
  • [32] Lysin cell-binding domain-functionalized magnetic beads for detection of Staphylococcus aureus via inhibition of fluorescence of Amplex Red/hydrogen peroxide assay by intracellular catalase
    Yi, Zhengjun
    Wang, Shuhui
    Meng, Xiangying
    Wu, Anqi
    Li, Qian
    Song, Yongjie
    Zhao, Ronglan
    Qiao, Jinjuan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (27) : 7177 - 7185
  • [33] Nucleic acid-functionalized upconversion luminescence biosensor based on strand displacement-mediated signal amplification for the detection of trivalent chromium ions
    Chen, Qiang
    Chen, Sisi
    Chen, Zhiwei
    Tang, Keren
    Zeng, Lupeng
    Sun, Weiming
    Wu, Fang
    Chen, Jinghua
    Lan, Jianming
    ANALYTICA CHIMICA ACTA, 2024, 1328
  • [34] An ultrasensitive and dual-recognition SERS biosensor based on Fe3O4@Au-Teicoplanin and aptamer functionalized Au@Ag nanoparticles for detection of Staphylococcus aureus
    Qi, Xiaoyu
    Ye, Yufei
    Wang, Hao
    Zhao, Bianbian
    Xu, Lixia
    Zhang, Yuting
    Wang, Xiaoli
    Zhou, Nandi
    TALANTA, 2022, 250
  • [35] A novel quantum dot fluorescence immunosensor based on magnetic beads and portable flow cytometry for detection of Okadaic acid
    Pan, Yuxiang
    Zhou, Jie
    Su, Kaiqi
    Hu, Ning
    Wang, Ping
    BIOSENSORS 2016, 2017, 27 : 214 - 216
  • [36] A Novel Turn-On Fluorescence Probe Based on Cu(II) Functionalized Metal-Organic Frameworks for Visual Detection of Uric Acid
    Yang, Jie
    Che, Jie
    Jiang, Xin
    Fan, Yangchun
    Gao, Daojiang
    Bi, Jian
    Ning, Zhanglei
    MOLECULES, 2022, 27 (15):
  • [37] A novel fluorescence "turn off - on" nanosensor for sensitivity detection acid phosphatase and inhibitor based on glutathione-functionalized graphene quantum dots
    Qu, Zhengyi
    Li, Ning
    Na, Weidan
    Su, Xingguang
    TALANTA, 2019, 192 : 61 - 68
  • [38] A magnetic bead-based assay for the rapid detection of methicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loop-mediated isothermal amplification
    Wang, Chih-Hung
    Lien, Kang-Yi
    Wu, Jiunn-Jong
    Lee, Gwo-Bin
    LAB ON A CHIP, 2011, 11 (08) : 1521 - 1531
  • [39] A SERS biosensor based on aptamer-based Fe3O4@SiO2@Ag magnetic recognition and embedded SERS probes for ultrasensitive simultaneous detection of Staphylococcus aureus and Escherichia coli
    Mi, Fang
    Guan, Ming
    Wang, Ying
    Chen, Guotong
    Geng, PengFei
    MICROCHEMICAL JOURNAL, 2023, 190
  • [40] Detection of Retinoic Acid-Active Chemicals in Diverse Sample Matrices Via a Quantum Dots-Based Nuclear Receptor Fluorescence Probe-Mediated Biosensor
    Tan, Jisui
    Zhou, Xiaohong
    ANALYTICAL CHEMISTRY, 2023, 95 (20) : 8036 - 8044