A novel PEG-mediated boric acid functionalized magnetic nanomaterials based fluorescence biosensor for the detection of Staphylococcus aureus

被引:23
|
作者
Wang, Zhengzheng [1 ]
Feng, Xiaoyan [1 ]
Xiao, Fangbin [1 ]
Bai, Xuekun [1 ]
Xu, Qian [1 ]
Xu, Hengyi [1 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, 235 Nanjing East Rd, Nanchang 330047, Jiangxi, Peoples R China
基金
国家重点研发计划;
关键词
Staphylococcus aureus; 3-aminophenylboronic acid; Magnetic separation; Fluorescence; OUTBREAK; GENES;
D O I
10.1016/j.microc.2022.107379
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Staphylococcus aureus (S. aureus) is one of the pathogens that seriously endanger human health and are widespread in nature. Food poisoning incidents caused by S. aureus frequently break out. Therefore, it is significant that a rapid and accurate method is established for S. aureus detection. In this study, a strategy using magnetic separation combine with fluorescence analysis was proposed for S. aureus detection. Boric acid can selectively enrich compounds with cis-diol groups through a reversible esterification reaction, and has been widely used in the identification of sugars and glycosylated molecules. As a boric acid derivative, 3-aminophenylboronic acid (APBA) has the advantages of stability, low cost, easy synthesis, etc. Therefore, using APBA as a recognition molecule to prepare magnetic nanomaterials can achieve the enrichment of S. aureus. In order to reduce steric hindrance and ensure the dominant orientation of APBA, thus improving the enrichment performance of target bacteria. The polyethylene glycol (PEG) was used as a mediator to prepare PEG-mediated APBA functionalized magnetic nanomaterials (APBA-PEG-MNs). In addition, this study used FITC-pig IgG to label S. aureus because the Fc fragment of IgG to bind protein A on the surface of S. aureus and realized the detection of S. aureus by detecting fluorescence. Under the optimal experimental conditions, the capture efficiency of APBA-PEG-MNs for S. aureus with the concentration of 2.7 x 10(6) CFU/mL in spinach, juice and pool water spiked samples was 92.6%, 91.6%, 91.6%. The limit of detection of the strategy in spiked samples was 2.7 x 10(2) CFU/mL within 80 min.
引用
收藏
页数:8
相关论文
共 49 条
  • [21] Loop-Mediated Isothermal Amplification Label-Based Gold Nanoparticles Lateral Flow Biosensor for Detection of Enterococcus faecalis and Staphylococcus aureus
    Wang, Yi
    Li, Hui
    Wang, Yan
    Zhang, Lu
    Xu, Jianguo
    Ye, Changyun
    FRONTIERS IN MICROBIOLOGY, 2017, 8
  • [22] Establishment of a real-time fluorescence and visual colorimetric detection method for Staphylococcus aureus based on loop-mediated isothermal amplification
    Cui, Xinping
    Guo, Jianping
    Wang, Zuwei
    Lu, Zhaoxin
    Meng, Fanqiang
    Bie, Xiaomei
    JOURNAL OF FOOD SAFETY, 2024, 44 (02)
  • [23] A novel glucose biosensor based on phosphonic acid-functionalized silica nanoparticles for sensitive detection of glucose in real samples
    Zhao, Wenbo
    Fang, Yi
    Zhu, Qinshu
    Wang, Kuai
    Liu, Min
    Huang, Xiaohua
    Shen, Jian
    ELECTROCHIMICA ACTA, 2013, 89 : 278 - 283
  • [24] Rapid and sensitive detection of Staphylococcus aureus using a THz metamaterial biosensor based on aptamer-functionalized Fe3O4@Au nanocomposites
    Yu, Wenjing
    Li, Jining
    Huang, Guorong
    He, Zhe
    Tian, Huiyan
    Xie, Fengxin
    Jin, Weidong
    Huang, Qing
    Fu, Weiling
    Yang, Xiang
    TALANTA, 2024, 272
  • [25] Rapid identification of Staphylococcus aureus based on a fluorescence imaging/detection platform that combines loop mediated isothermal amplification assay and the smartphone-based system
    Cabrales-Arellano, Patricia
    Park, Edward
    Minor, Martha
    Delgado, Efren
    Valles-Rosales, Delia
    Taboada, Heidi
    Espiritu, Jose
    Su, Jianzhong
    Park, Young Ho
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [26] Rapid identification of Staphylococcus aureus based on a fluorescence imaging/detection platform that combines loop mediated isothermal amplification assay and the smartphone-based system
    Patricia Cabrales-Arellano
    Edward Park
    Martha Minor
    Efren Delgado
    Delia Valles-Rosales
    Heidi Taboada
    José Espiritu
    Jianzhong Su
    Young Ho Park
    Scientific Reports, 12
  • [27] A fluorescence resonance energy transfer (FRET) biosensor based on graphene quantum dots (GQDs) and gold nanoparticles (AuNPs) for the detection of mecA gene sequence of Staphylococcus aureus
    Shi, Jingyu
    Chan, Chunyu
    Pang, Yukting
    Ye, Weiwei
    Tian, Feng
    Lyu, Jing
    Zhang, Yu
    Yang, Mo
    BIOSENSORS & BIOELECTRONICS, 2015, 67 : 595 - 600
  • [28] A novel fluorescence biosensor for sensitivity detection of tyrosinase and acid phosphatase based on nitrogen-doped graphene quantum dots
    Qu, Zhengyi
    Na, Weidan
    Liu, Xiaotong
    Liu, Hua
    Su, Xingguang
    ANALYTICA CHIMICA ACTA, 2018, 997 : 52 - 59
  • [29] A novel Fe3O4 magnetic nanoparticles functionalized by glutamic acid and conjugated with thiosemicarbazide alter the expression of norB gene, in Staphylococcus aureus
    Safarnejad, Erfan
    Moradi-Shoeili, Zeinab
    Rahmatollahi, Hamid Reza
    Jalali, Amir
    Salehzadeh, Ali
    MICRO & NANO LETTERS, 2022, 17 (04) : 86 - 95
  • [30] Rapid detection of SARS-CoV-2 spike protein using a magnetic-assisted electrochemical biosensor based on functionalized CoFe2O4 magnetic nanomaterials
    Zhao, Bing
    Xiong, Chan-Ru
    Liu, Yao
    Yu, Qing-Cai
    Chen, Xing
    TALANTA, 2024, 274