Influence of optical probe packaging on a 3D MEMS scanning micro-mirror for optical coherence tomography (OCT) applications

被引:2
|
作者
Khairyanto, C. S. Premachandran Ahmad [1 ]
Chen, Kelvin [1 ]
Singh, Jank [1 ]
Wang, Sandy X. L. [1 ]
Xu Yingshun [2 ]
Chen Nanguang [2 ]
Sheppard, C. J. R. [2 ]
Olivo, Malini [3 ]
Lau, John [1 ]
机构
[1] Inst Microelectron, ASTAR, 11 Sci Pk Rd,Singapore Sci Pk 2, Singapore 117685, Singapore
[2] Natl Univ Singapore, Dept Bioengn, Singapore, Singapore
[3] Natl Canc Ctr, Div Med Sci, Singapore 169610, Singapore
关键词
D O I
10.1109/ECTC.2008.4550072
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An optical probe is developed for imaging in an optical coherence tomography (OCT) system. A 3D micro mirror is used for steering the beam from the source to the sample. A GRIN lens, fiber and micro mirror are assembled in a silicon optical bench. The assembled components are housed in the bio-compatible microinjection molded housing. The images obtained using this probe is studied with respect to probe assembly. Tolerance of GRIN lens placement, micro mirror placement on the substrate, deformation of the mirror, housing transparency and housing curvature are studied with respect to the final image from the probe. In this study it is found that a higher mirror curvature affects the depth of focus on the sample and mirror placement reduces the coupling efficiency during the optical assembly.
引用
收藏
页码:829 / +
页数:2
相关论文
共 50 条
  • [31] Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror
    Lu, Chen D.
    Kraus, Martin F.
    Potsaid, Benjamin
    Liu, Jonathan J.
    Choi, WooJhon
    Jayaraman, Vijaysekhar
    Cable, Alex E.
    Hornegger, Joachim
    Duker, Jay S.
    Fujimoto, James G.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 293 - 311
  • [32] Handheld miniature probe integrating diffuse optical tomography with photoacoustic imaging through a MEMS scanning mirror
    Yang, Hao
    Xi, Lei
    Samuelson, Sean
    Xie, Huikai
    Yang, Lily
    Jiang, Huabei
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (03): : 427 - 432
  • [33] Scanning protocol choice affects optical coherence tomography (OCT-3) measurements
    Zafar, S
    Gurses-Ozden, R
    Makornwattana, M
    Vessani, R
    Liebmann, JM
    Tello, C
    Ritch, R
    JOURNAL OF GLAUCOMA, 2004, 13 (02) : 142 - 144
  • [34] Optical coherent tomography (OCT) bio-imaging using 3D scanning micromirror
    Singh, J.
    Hoe, Chan C.
    Jason, Teo H. S.
    Nanguang, C.
    Premachandran, C. S.
    Sheppard, Colin J. R.
    Olivo, M.
    ENDOSCOPIC MICROSCOPY II, 2007, 6432
  • [35] A linearly optical scanning mirror for real-time imaging of optical coherence tomography
    Lin, CH
    Hou, MTK
    Hsu, IJ
    Wen, DC
    IEEE/LEOS OPTICAL MEMS 2005: INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND THEIR APPLICATIONS, 2005, : 59 - 60
  • [36] Applications of Optical Coherence Tomography (OCT) in Neuro-ophthalmology
    Kernstock, C.
    Friebe, K.
    Tonagel, F.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2013, 230 (11) : 1097 - 1105
  • [37] OPTICAL COHERENCE TOMOGRAPHY VCSELs accelerate new OCT applications
    Overton, Gail
    LASER FOCUS WORLD, 2013, 49 (04): : 26 - 27
  • [38] Repeatability and Reproducibility of optical coherence tomography (OCT) measurements from the Topcon 3D OCT-1 Maestro
    Hoffmeyer, Greg
    Hou, Huiyuan
    Durbin, Mary
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [39] Study on an all-fiber optical coherence tomography (OCT) probe
    Huang, Xiaoqian
    Tong, X. L.
    OPTICAL FIBER TECHNOLOGY, 2023, 79
  • [40] DEMONSTRATION OF MOUSE TRACHEA IMAGING WITH A FLEXIBLE MICRO-OPTICAL COHERENCE TOMOGRAPHY (μOCT) ENDOBRONCHIAL PROBE
    Cui, D.
    Leung, H.
    Chu, K.
    Ford, T.
    Hyun, C.
    Yin, B.
    Singh, K.
    Birket, S.
    Solomon, G.
    Rowe, S. M.
    Tearney, G. J.
    PEDIATRIC PULMONOLOGY, 2016, 51 : 240 - 240