A Comparison of Laparoscopic Energy Devices on Charges in Thermal Power After Application to Porcine Mesentery

被引:9
|
作者
Eto, Ken [1 ]
Omura, Nobuo [1 ]
Haruki, Koichiro [1 ]
Uno, Yoshiko [1 ]
Ohkuma, Masahisa [1 ]
Nakajima, Shintaro [1 ]
Anan, Tadashi [1 ]
Kosuge, Makoto [1 ]
Fujita, Tetsuji [1 ]
Yanaga, Katsuhiko [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Surg, Minato Ku, Tokyo 1058461, Japan
关键词
laparoscopy; energy device; thermal injury; HARMONIC SCALPEL; ULTRASONIC ENERGY; MONOPOLAR; LIGASURE; ARTERIES; ELECTROCOAGULATION; CHOLECYSTECTOMY; HEMOSTASIS; DISSECTION; DIATHERMY;
D O I
10.1097/SLE.0000000000000059
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Advances in energy devices have played a major role in the rapid expansion of laparoscopic surgery. However, complications due to these energy devices are occasionally reported, and if the characteristics of these devices are not well understood, serious complications may occur. This study evaluated various typical energy devices and measured temperature rises in the adjacent tissue and in the devices themselves. Equipment and Methods: We used the following 7 types of energy devices: AutoSonix (AU), SonoSurg (SS), Harmonic Scalpel (HS), LigaSure Atlas (LA), LigaSure Dolphin Tip (LD), monopolar diathermy (Mono), and bipolar scissors (Bi). Laparoscopy was performed under general anesthesia in pigs, and the mesentery was dissected using each energy device. Tissue temperature at a distance of 1mm from the energy device blade before and after dissection was measured. Temperature of the device blade both before and after dissection, time required for dissection, and interval until the temperature fell to 100 degrees C, 75 degrees C, and 50 degrees C were documented. Results: Temperature of the surrounding tissue using each device rose the most with the Mono (50.5 +/- 8.0 degrees C) and the least with the HS in full mode (6.2 +/- 0.7 degrees C). Device temperature itself rose the highest with the AU in full mode (318.2 +/- 49.6 degrees C), and the least with the Bi (61.9 +/- 4.8 degrees C). All ultrasonic coagulation and cutting devices (AU, SS, and HS) had device temperatures increase up to >= 100 degrees C, and even at 8 seconds after completing dissection, temperatures remained at >= 100 degrees C. Conclusions: Because the adjacent tissue temperature peaked with the Mono, cautious use near the intestine and blood vessels is necessary. In addition, the active blades of all ultrasonic coagulation and cutting devices, regardless of model, developed high temperatures exceeding 100 degrees C. Therefore, an adequate cooling period after using these devices is therefore necessary between applications.
引用
收藏
页码:E37 / E41
页数:5
相关论文
共 50 条
  • [41] Application of ultra-high energy boron implantation for superjunction power (CoolMOS™) devices
    von Borany, J
    Friedrich, M
    Rüb, M
    Deboy, G
    Butschke, J
    Letzkus, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 237 (1-2): : 62 - 67
  • [42] Ragone plots and discharge efficiency-power relations of electric and thermal energy storage devices
    Christen, Thomas
    JOURNAL OF ENERGY STORAGE, 2020, 27 (27):
  • [43] THERMAL ENERGY STORAGE TECHNOLOGY AND ITS APPLICATION IN POWER DATA REMOTE TRANSMISSION
    Xu, Aixue
    Qi, Huijuan
    Wen, Hongnian
    THERMAL SCIENCE, 2023, 27 (2A): : 1175 - 1181
  • [44] Application-Aware Lifetime Model for Power Devices based on Electro-Thermal Simulation
    Pop, Ciprian V.
    Buzo, Andi
    Diaconu, Cristian V.
    Pelz, Georg
    Cucu, Horia
    Burileanu, Corneliu
    2019 INTERNATIONAL SEMICONDUCTOR CONFERENCE (CAS 2019), 42ND EDITION, 2019, : 177 - 180
  • [45] New energy-based devices in laparoscopic splenectomy: Comparison of Ligasure alone versus Ligasure and Ultracision together
    Kurt, Yavuz
    Yucel, Ergun
    Filiz, Ali Ilker
    Sucullu, Ilker
    Akin, Mehmet Levhi
    SURGICAL PRACTICE, 2012, 16 (01) : 28 - 32
  • [46] Application of Joint Frequency Regulation Technology of Energy Storage and Thermal Power in China Southern Power Grid
    Xie H.
    Wang C.
    Liu P.
    Liu H.
    Xu G.
    Li P.
    Song Y.
    Mei Y.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (04): : 172 - 179
  • [47] Application of Mechanical Energy Storage Devices in Autonomous Power Sources for Butt Welding Machines.
    Lebedev, V.K.
    Prodan, S.K.
    Avtomaticheskaya Svarka, 1978, (04): : 1 - 4
  • [48] Comparison of Postoperative Bleed Rates and Location of Bleed Between Vessel Sealing Devices after Laparoscopic Sleeve Gastrectomy
    Cuva, Dylan
    Park, Julia
    Chui, Patricia
    Lipman, Jeffrey
    Einersen, Peter
    Saunders, John K.
    Parikh, Manish
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2025, 35 (01): : 1 - 5
  • [49] A comparison of projected and actual energy performance of buildings after thermal retrofit measures
    Housez, P. P.
    Pont, U.
    Mahdavi, A.
    CONTRIBUTIONS TO BUILDING PHYSICS, 2013, : 229 - 235
  • [50] A comparison of projected and actual energy performance of buildings after thermal retrofit measures
    Housez, Pierre Pascal
    Pont, Ulrich
    Mahdavi, Ardeshir
    JOURNAL OF BUILDING PHYSICS, 2014, 38 (02) : 138 - 155