Improved quantification of myelin water fraction using joint sparsity of T2* distribution

被引:6
|
作者
Chen, Quan [1 ]
She, Huajun [1 ]
Du, Yiping P. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Inst Med Imaging Technol, Shanghai 20030, Peoples R China
关键词
multiexponential T2*relaxometry; demyelination; myelin water fraction; group information; nonnegative joint sparsity; L-1; 2-norm regularization; MULTIPLE-SCLEROSIS; BRAIN; MODEL; ALGORITHM; DECAY;
D O I
10.1002/jmri.27013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Myelin water fraction (MWF) can be quantified with analysis of the T-2* distribution, whereas deducing the T-2* spectrum from several echoes is an underdetermined and ill-posed problem. Purpose To improve the quantification of myelin water content by using nonnegative jointly sparse (NNJS) optimization. Study Type Prospective. Subjects Nine healthy subjects. Field Strength/Sequence 3T, multiecho gradient echo. Assessment The results of NNJS were compared with that of the nonnegative least square (NNLS)-based algorithms. Simulated models with varied MWF at different noise levels were used to evaluate the accuracy of estimations. In human data, the MWF values of different regions were compared with previous studies and the coefficient of variation (COV) was used to assess the spatial coherence. Statistical Test Paired t-test. Results In simulation, the relative errors of MWF obtained from synthesized data with signal-to-noise ratio (SNR) at 500, 200, 150, and 100 were 0.08, 0.09, 0.10, and 0.12 for NNJS, 0.29, 0.43, 0.48, and 0.53 for regularized NNLS (rNNLS), and 0.19, 0.24, 0.25, and 0.26 for spatially-regularized NNLS (srNNLS). In human data, the mean values of MWF produced by NNJS in different regions were consistent with previous studies. Compared with the NNLS-based algorithms, lower COVs generated by NNJS were observed in genu, forceps minor, forceps major, and internal capsule, which were 0.44 +/- 0.08, 0.48 +/- 0.07, 0.46 +/- 0.03, and 0.48 +/- 0.09 in NNJS, 0.88 +/- 0.28, 0.96 +/- 0.18, 0.72 +/- 0.03, and 0.85 +/- 0.15 in rNNLS, and 0.56 +/- 0.17, 0.64 +/- 0.14, 0.50 +/- 0.04 and 0.58 +/- 0.13 in srNNLS. Data Conclusion Quantitative results of both simulated and human data show that NNJS provides more plausible estimation than the NNLS-based algorithms. Visual advantages of NNJS in spatial consistency can be confirmed by the comparative COV index. The proposed algorithm might improve the quantification of myelin water content. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019.
引用
收藏
页码:146 / 158
页数:13
相关论文
共 50 条
  • [1] Editorial on "Improved Quantification of Myelin Water Fraction Using Joint Sparsity of T2* Distribution"
    Leote, Joao
    Nunes, Rita G.
    Ferreira, Hugo A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (01) : 159 - 160
  • [2] Myelin water imaging from multi-echo T2 MR relaxometry data using a joint sparsity constraint
    Nagtegaal, Martijn
    Koken, Peter
    Amthor, Thomas
    de Bresser, Jeroen
    Maedler, Burkhard
    Vos, Frans
    Doneva, Mariya
    NEUROIMAGE, 2020, 219
  • [3] A spatially regularised approach to myelin water fraction imaging using T2 relaxometry
    Kumar, D.
    Nguyen, T.
    Vartanian, T.
    Gauthier, S.
    Raj, A.
    MULTIPLE SCLEROSIS JOURNAL, 2011, 17 : S391 - S392
  • [4] Water content and myelin water fraction in multiple sclerosisA T2 relaxation study
    C. Laule
    I. M. Vavasour
    G. R. W. Moore
    J. Oger
    D. K. B. Li
    D. W. Paty
    A. L. MacKay
    Journal of Neurology, 2004, 251 : 284 - 293
  • [5] Water content and myelin water fraction in multiple sclerosis -: A T2 relaxation study
    Laule, C
    Vavasour, IM
    Moore, GRW
    Oger, J
    Li, DKB
    Paty, DW
    MacKay, AL
    JOURNAL OF NEUROLOGY, 2004, 251 (03) : 284 - 293
  • [6] ROBUST T2 RELAXOMETRY WITH HAMILTONIAN MCMC FOR MYELIN WATER FRACTION ESTIMATION
    Yu, Thomas
    Pizzolato, Marco
    Canales-Rodriguez, Erick Jorge
    Thiran, Jean-Philippe
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 1813 - 1817
  • [7] Simultaneous measurement of total water content and myelin water fraction in brain at 3 T using a T2 relaxation based method
    Meyers, Sandra M.
    Kolind, Shannon H.
    MacKay, Alex L.
    MAGNETIC RESONANCE IMAGING, 2017, 37 : 187 - 194
  • [8] Comparison of non-parametric T2 relaxometry methods for myelin water quantification
    Jorge Canales-Rodriguez, Erick
    Pizzolato, Marco
    Franco Piredda, Gian
    Hilbert, Tom
    Kunz, Nicolas
    Pot, Caroline
    Yu, Thomas
    Salvador, Raymond
    Pomarol-Clotet, Edith
    Kober, Tobias
    Thiran, Jean-Philippe
    Daducci, Alessandro
    MEDICAL IMAGE ANALYSIS, 2021, 69
  • [9] Accelerated T2*-Compensated Fat Fraction Quantification Using a Joint Parallel Imaging and Compressed Sensing Framework
    Sharma, Samir D.
    Hu, Houchun H.
    Nayak, Krishna S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (05) : 1267 - 1275
  • [10] A Multivariate Approach for Denoising of T2 Relaxation Decay Curves in Myelin Water Fraction Imaging
    Baumeister, Tobias R.
    Wang, Z. Jane
    McKeown, Martin J.
    2019 7TH IEEE GLOBAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING (IEEE GLOBALSIP), 2019,