A Multivariate Approach for Denoising of T2 Relaxation Decay Curves in Myelin Water Fraction Imaging

被引:0
|
作者
Baumeister, Tobias R. [1 ]
Wang, Z. Jane [2 ,3 ]
McKeown, Martin J. [4 ,5 ]
机构
[1] Univ British Columbia, Sch Biomed Engn, Vancouver, BC, Canada
[2] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC, Canada
[3] Northwest Univ, Sch Informat Sci & Technol, Xian, Peoples R China
[4] Univ British Columbia, Dept Med Neurol, Vancouver, BC, Canada
[5] Univ British Columbia, Pacific Parkinsons Res Ctr, Vancouver, BC, Canada
关键词
brain imaging; T2; relaxation; myelin water fraction; quantitative MRI; white matter; SETS;
D O I
10.1109/globalsip45357.2019.8969130
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Accurately measuring brain myelin content in vivo holds great promise for studying and understanding of number of brain diseases. A surrogate marker for myelin, myelin water fraction (MWF), can be measured with MR relaxation techniques that sample the T2 decay with multiple echoes. Low signalto-noise ratios in later echoes, sub-optimal flip angles, and the fact that robust decomposition into multiple exponential curves is notoriously difficult, all conspire to reduce the accuracy of MWF estimates. The resulting maps are typically spatially noisy -- despite the fact that adjacent white matter voxels are usually assumed to have similar myelin measures in vivo. Here we propose a spatio-temporal filtering process prior to the standard fitting based on a combination of multivariate empirical mode decomposition (MEMD) and multiset canonical correlation analysis (MCCA) to decompose and find the most robust temporal decay pattern among voxels that have similar overall decay curves and across the white matter. Based on enhanced spatial smoothness measures, increased test-retest reliability within subjects, and decreased Coefficient of Variation of MWF scores, we suggest that the proposed approach provides enhanced accuracy of the ultimately-computed MWF maps.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A spatially regularised approach to myelin water fraction imaging using T2 relaxometry
    Kumar, D.
    Nguyen, T.
    Vartanian, T.
    Gauthier, S.
    Raj, A.
    MULTIPLE SCLEROSIS JOURNAL, 2011, 17 : S391 - S392
  • [2] Water content and myelin water fraction in multiple sclerosisA T2 relaxation study
    C. Laule
    I. M. Vavasour
    G. R. W. Moore
    J. Oger
    D. K. B. Li
    D. W. Paty
    A. L. MacKay
    Journal of Neurology, 2004, 251 : 284 - 293
  • [3] Water content and myelin water fraction in multiple sclerosis -: A T2 relaxation study
    Laule, C
    Vavasour, IM
    Moore, GRW
    Oger, J
    Li, DKB
    Paty, DW
    MacKay, AL
    JOURNAL OF NEUROLOGY, 2004, 251 (03) : 284 - 293
  • [4] In-Vivo Myelin Water Imaging using T2*Decay at 7T
    Sati, Pascal
    Silva, Afonso C.
    Gaitan, Maria I.
    Wohler, Jillian E.
    Evangelou, Iordanis E.
    Massacesi, Luca
    Jacobson, Steven
    Reich, Daniel S.
    ANNALS OF NEUROLOGY, 2010, 68 (04) : S34 - S34
  • [5] Impact of magnetic susceptibility anisotropy at 3 T and 7 T on T2*-based myelin water fraction imaging
    Alonso-Ortiz, Eva
    Levesque, Ives R.
    Pike, G. Bruce
    NEUROIMAGE, 2018, 182 : 370 - 378
  • [6] Comparison of Myelin Water Fraction from Multiecho T2 Decay Curve and Steady-State Methods
    Zhang, Jing
    Kolind, Shannon H.
    Laule, Cornelia
    MacKay, Alex L.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 223 - 232
  • [7] Simultaneous measurement of total water content and myelin water fraction in brain at 3 T using a T2 relaxation based method
    Meyers, Sandra M.
    Kolind, Shannon H.
    MacKay, Alex L.
    MAGNETIC RESONANCE IMAGING, 2017, 37 : 187 - 194
  • [8] Multi-spin echo T2 relaxation imaging with compressed sensing (METRICS) for rapid myelin water imaging
    Dvorak, Adam V.
    Wiggermann, Vanessa
    Gilbert, Guillaume
    Vavasour, Irene M.
    MacMillan, Erin L.
    Barlow, Laura
    Wiley, Neale
    Kozlowski, Piotr
    MacKay, Alex L.
    Rauscher, Alexander
    Kolind, Shannon H.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) : 1264 - 1279
  • [9] ROBUST T2 RELAXOMETRY WITH HAMILTONIAN MCMC FOR MYELIN WATER FRACTION ESTIMATION
    Yu, Thomas
    Pizzolato, Marco
    Canales-Rodriguez, Erick Jorge
    Thiran, Jean-Philippe
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 1813 - 1817
  • [10] Mechanisms of T2* anisotropy and gradient echo myelin water imaging
    Lee, Jongho
    Nam, Yoonho
    Choi, Joon Yul
    Kim, Eung Yeop
    Oh, Se-Hong
    Kim, Dong-Hyun
    NMR IN BIOMEDICINE, 2017, 30 (04)