A Multivariate Approach for Denoising of T2 Relaxation Decay Curves in Myelin Water Fraction Imaging

被引:0
|
作者
Baumeister, Tobias R. [1 ]
Wang, Z. Jane [2 ,3 ]
McKeown, Martin J. [4 ,5 ]
机构
[1] Univ British Columbia, Sch Biomed Engn, Vancouver, BC, Canada
[2] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC, Canada
[3] Northwest Univ, Sch Informat Sci & Technol, Xian, Peoples R China
[4] Univ British Columbia, Dept Med Neurol, Vancouver, BC, Canada
[5] Univ British Columbia, Pacific Parkinsons Res Ctr, Vancouver, BC, Canada
关键词
brain imaging; T2; relaxation; myelin water fraction; quantitative MRI; white matter; SETS;
D O I
10.1109/globalsip45357.2019.8969130
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Accurately measuring brain myelin content in vivo holds great promise for studying and understanding of number of brain diseases. A surrogate marker for myelin, myelin water fraction (MWF), can be measured with MR relaxation techniques that sample the T2 decay with multiple echoes. Low signalto-noise ratios in later echoes, sub-optimal flip angles, and the fact that robust decomposition into multiple exponential curves is notoriously difficult, all conspire to reduce the accuracy of MWF estimates. The resulting maps are typically spatially noisy -- despite the fact that adjacent white matter voxels are usually assumed to have similar myelin measures in vivo. Here we propose a spatio-temporal filtering process prior to the standard fitting based on a combination of multivariate empirical mode decomposition (MEMD) and multiset canonical correlation analysis (MCCA) to decompose and find the most robust temporal decay pattern among voxels that have similar overall decay curves and across the white matter. Based on enhanced spatial smoothness measures, increased test-retest reliability within subjects, and decreased Coefficient of Variation of MWF scores, we suggest that the proposed approach provides enhanced accuracy of the ultimately-computed MWF maps.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] A data-driven T2 relaxation analysis approach for myelin water imaging: Spectrum analysis for multiple exponentials via experimental condition oriented simulation (SAME-ECOS)
    Liu, Hanwen
    Joseph, Tigris S.
    Xiang, Qing-San
    Tam, Roger
    Kozlowski, Piotr
    Li, David K. B.
    MacKay, Alex L.
    Kramer, John L. K.
    Laule, Cornelia
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) : 915 - 931
  • [32] A SIMPLE APPROACH TO T2 IMAGING IN MRI
    POPE, JM
    REPIN, N
    MAGNETIC RESONANCE IMAGING, 1988, 6 (06) : 641 - 646
  • [33] Improved quantification of T2* relaxation in magnetic resonance imaging
    Einar Heiberg
    Jane Sjögren
    Håkan Arheden
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [34] Optimized spiral imaging for measurement of myocardial T2 relaxation
    Foltz, WD
    Al-Kwifi, O
    Sussman, MS
    Stainsby, JA
    Wright, GA
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) : 1089 - 1097
  • [35] Myelin Water Fraction and Intra/Extracellular Water Geometric Mean T2 Normative Atlases for the Cervical Spinal Cord from 3T MRI
    Liu, Hanwen
    Ljungberg, Emil
    Dvorak, Adam V.
    Lee, Lisa Eunyoung
    Yik, Jackie T.
    MacMillan, Erin L.
    Barlow, Laura
    Li, David K. B.
    Traboulsee, Anthony
    Kolind, Shannon H.
    Kramer, John L. K.
    Laule, Cornelia
    JOURNAL OF NEUROIMAGING, 2020, 30 (01) : 50 - 57
  • [36] DETECTION OF BI-EXPONENTIAL T2 DECAY INVIVO IMAGING
    TOFTS, PS
    JOHNSON, G
    BARNES, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (11): : 1313 - 1313
  • [37] T2 relaxation measurements of in vivo water content and myelin water content in normal-appearing white matter and lesions in multiple sclerosis
    Laule, C
    Vavasour, IM
    Oger, J
    Paty, DW
    Li, DKB
    MacKay, AL
    NEUROLOGY, 2002, 58 (07) : A205 - A205
  • [38] Imaging Approach to the Cord T2 Hyperintensity (Myelopathy)
    Grayev, Allison M.
    Kissane, Jennifer
    Kanekar, Sangam
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2014, 52 (02) : 427 - +
  • [39] Fast Calculation of T2 Relaxation Time in Magnetic Resonance Imaging
    Mikulka, J.
    Dvorak, P.
    PIERS 2014 GUANGZHOU: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2014, : 2331 - 2335
  • [40] Multivariate multinomial T2 control chart using fuzzy approach
    Pastuizaca Fernandez, Maria Nela
    Carrion Garcia, Andres
    Ruiz Barzola, Omar
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2015, 53 (07) : 2225 - 2238