Improved quantification of myelin water fraction using joint sparsity of T2* distribution

被引:6
|
作者
Chen, Quan [1 ]
She, Huajun [1 ]
Du, Yiping P. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Inst Med Imaging Technol, Shanghai 20030, Peoples R China
关键词
multiexponential T2*relaxometry; demyelination; myelin water fraction; group information; nonnegative joint sparsity; L-1; 2-norm regularization; MULTIPLE-SCLEROSIS; BRAIN; MODEL; ALGORITHM; DECAY;
D O I
10.1002/jmri.27013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Myelin water fraction (MWF) can be quantified with analysis of the T-2* distribution, whereas deducing the T-2* spectrum from several echoes is an underdetermined and ill-posed problem. Purpose To improve the quantification of myelin water content by using nonnegative jointly sparse (NNJS) optimization. Study Type Prospective. Subjects Nine healthy subjects. Field Strength/Sequence 3T, multiecho gradient echo. Assessment The results of NNJS were compared with that of the nonnegative least square (NNLS)-based algorithms. Simulated models with varied MWF at different noise levels were used to evaluate the accuracy of estimations. In human data, the MWF values of different regions were compared with previous studies and the coefficient of variation (COV) was used to assess the spatial coherence. Statistical Test Paired t-test. Results In simulation, the relative errors of MWF obtained from synthesized data with signal-to-noise ratio (SNR) at 500, 200, 150, and 100 were 0.08, 0.09, 0.10, and 0.12 for NNJS, 0.29, 0.43, 0.48, and 0.53 for regularized NNLS (rNNLS), and 0.19, 0.24, 0.25, and 0.26 for spatially-regularized NNLS (srNNLS). In human data, the mean values of MWF produced by NNJS in different regions were consistent with previous studies. Compared with the NNLS-based algorithms, lower COVs generated by NNJS were observed in genu, forceps minor, forceps major, and internal capsule, which were 0.44 +/- 0.08, 0.48 +/- 0.07, 0.46 +/- 0.03, and 0.48 +/- 0.09 in NNJS, 0.88 +/- 0.28, 0.96 +/- 0.18, 0.72 +/- 0.03, and 0.85 +/- 0.15 in rNNLS, and 0.56 +/- 0.17, 0.64 +/- 0.14, 0.50 +/- 0.04 and 0.58 +/- 0.13 in srNNLS. Data Conclusion Quantitative results of both simulated and human data show that NNJS provides more plausible estimation than the NNLS-based algorithms. Visual advantages of NNJS in spatial consistency can be confirmed by the comparative COV index. The proposed algorithm might improve the quantification of myelin water content. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019.
引用
收藏
页码:146 / 158
页数:13
相关论文
共 50 条
  • [31] Fat quantification and T2 measurement
    Noura Azzabou
    Pierre G. Carlier
    Pediatric Radiology, 2014, 44 : 1620 - 1621
  • [32] Fat quantification and T2 measurement
    Azzabou, Noura
    Carlier, Pierre G.
    PEDIATRIC RADIOLOGY, 2014, 44 (12) : 1620 - 1621
  • [33] Data-driven myelin water imaging based on T1 and T2 relaxometry
    Piredda, Gian Franco
    Hilbert, Tom
    Ravano, Veronica
    Canales-Rodriguez, Erick Jorge
    Pizzolato, Marco
    Meuli, Reto
    Thiran, Jean-Philippe
    Richiardi, Jonas
    Kober, Tobias
    NMR IN BIOMEDICINE, 2022, 35 (07)
  • [34] Relationship of apparent myocardial T2 and oxygenation:: Towards quantification of myocardial oxygen extraction fraction
    Zheng, J
    Wang, JH
    Rowold, FE
    Gropler, RJ
    Woodard, PK
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (02) : 233 - 241
  • [35] Cardiac cine magnetic resonance fingerprinting for combined ejection fraction, T1 and T2 quantification
    Hamilton, Jesse I.
    Jiang, Yun
    Eck, Brendan
    Griswold, Mark
    Seiberlich, Nicole
    NMR IN BIOMEDICINE, 2020, 33 (08)
  • [36] ACCURATE T2 MAPPING WITH SPARSITY AND LINEAR PREDICTABILITY FILTERING
    Peng, Xi
    Ying, Leslie
    Liu, Xin
    Liang, Dong
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 161 - 164
  • [37] Myocardial T1, T2, T2*, and fat fraction quantification via low-rank motion-corrected cardiac MR fingerprinting
    da Cruz, Gastao Jose Lima
    Velasco, Carlos
    Lavin, Begona
    Jaubert, Olivier
    Michael Botnar, Rene
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (06) : 2757 - 2774
  • [38] Feasibility of MRI Quantification of Myelin Water Fraction in the Fetal Guinea Pig Brain
    Sethi, Simran
    Friesen-Waldner, Lanette J.
    Wade, Trevor P.
    Courchesne, Marc
    Nygard, Karen
    Sarr, Ousseynou
    Sutherland, Brian
    Regnault, Timothy R. H.
    McKenzie, Charles A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (06) : 1856 - 1864
  • [39] Magnetic Resonance Fingerprinting Using Echo-Planar Imaging: Joint Quantification of T1 and T2* Relaxation Times
    Rieger, Benedikt
    Zimmer, Fabian
    Zapp, Jascha
    Weingaertner, Sebastian
    Schad, Lothar R.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1724 - 1733
  • [40] Simultaneous muscle water T2 and fat fraction mapping using transverse relaxometry with stimulated echo compensation
    Marty, Benjamin
    Baudin, Pierre-Yves
    Reyngoudt, Harmen
    Azzabou, Noura
    Araujo, Ericky C. A.
    Carlier, Pierre G.
    de Sousa, Paulo L.
    NMR IN BIOMEDICINE, 2016, 29 (04) : 431 - 443