Comparison of dose volume parameters evaluated using three forward planning - optimization techniques in cervical cancer brachytherapy involving two applicators

被引:10
|
作者
Chakrobarti, Bikramjit [1 ,2 ]
Basu-Roy, Somapriya
Kar, Sanjay Kumar
Das, Sounik
Lahiri, Annesha
机构
[1] Inst Postgrad Med Educ & Res, Dept Radiotherapy, Kolkata 700020, India
[2] Seth Sukhlal Kernani Mem Hosp, Kolkata 700020, India
关键词
cervical cancer; cervix; carcinoma; dosimetry; optimization; INTRACAVITARY BRACHYTHERAPY; AMERICAN BRACHYTHERAPY; COMPUTED-TOMOGRAPHY; MRI; RECOMMENDATIONS; BLADDER; GUIDELINES; CARCINOMA; ANATOMY; TANDEM;
D O I
10.5114/jcb.2017.70677
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study is intended to compare dose-volume parameters evaluated using different forward planning optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose rate (HDR) fractionation schedules. Material and methods: We used tandem-ring and Fletcher-style tandem-ovoid applicator in same patients in two fractions of brachytherapy. Six plans were generated for each patient utilizing 3 forward optimization techniques for each applicator used: equal dwell weight/times ('no optimization'), 'manual dwell weight/times', and 'graphical'. Plans were normalized to left point A and dose of 8 Gy was prescribed. Dose volume and dose point parameters were compared. Results: Without graphical optimization, maximum width and thickness of volume enclosed by 100% isodose line, dose to 90%, and 100% of clinical target volume (CTV); minimum, maximum, median, and average dose to both rectum and bladder are significantly higher with Fletcher applicator. Even if it is done, dose to both points B, minimum dose to CTV, and treatment time; dose to 2 cc (D-2cc) rectum and rectal point etc.; D-2cc, minimum, maximum, median, and average dose to sigmoid colon; D-2cc of bladder remain significantly higher with this applicator. Dose to bladder point is similar (p > 0.05) between two applicators, after all optimization techniques. Conclusions: Fletcher applicator generates higher dose to both CTV and organs at risk (2 cc volumes) after all optimization techniques. Dose restriction to rectum is possible using graphical optimization only during selected HDR fractionation schedules. Bladder always receives dose higher than recommended, and 2 cc sigmoid colon always gets permissible dose. Contrarily, graphical optimization with ring applicators fulfills all dose volume objectives in all HDR fractionations practiced.
引用
收藏
页码:431 / 445
页数:15
相关论文
共 50 条
  • [41] CORRELATION BETWEEN IN-VIVO DOSIMETRY AND 3D DOSE VOLUME PARAMETERS IN PDR BRACHYTHERAPY OF CERVICAL CANCER
    Kallehauge, J.
    Nielsen, S. K.
    Fokdal, L. U.
    Lindegaard, J. C.
    Tanderup, K.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S119 - S119
  • [42] Comparison between Cone Beam CT Based Three-dimensional Planning and Modified Monte Carlo Dose Calculations in Intracavitary Brachytherapy for Cervical Cancer
    Al-Halabi, H.
    Poon, E.
    Portelance, L.
    Duclos, M.
    Souhami, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S623 - S623
  • [43] Influence of transitioning of planning techniques in high-dose-rate brachytherapy monotherapy for clinically localized prostate cancer from two- to three-dimensional planning
    Yamazaki, Hideya
    Masui, Koji
    Suzuk, Gen
    Nakamur, Satoaki
    Yoshida, Ken
    Kotsuma, Tadayuki
    Tanaka, Eiichi
    Otani, Keisuke
    Yoshioka, Yasuo
    Ogawa, Kazuhiko
    BRACHYTHERAPY, 2019, 18 (05) : 589 - 597
  • [44] Comparison of cervical esophagus dose-volumes for three radiotherapy techniques for head and neck cancer
    Chen, Jergin
    Shrieve, Dennis Charles
    Hitchcock, Ying Jia
    RADIOTHERAPY AND ONCOLOGY, 2008, 87 (02) : 274 - 280
  • [45] Comparison of cervical esophagus dose-volumes with three radiotherapy techniques for head and neck cancer
    Chen, J.
    Shrieve, D. C.
    Hitchcock, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S432 - S433
  • [46] Comparison of point a based plans with clinical target volume-based three-dimensional plans using dose-volume parameters in small lesion of cervical cancer brachyterapy
    Ozer, Elif Eda
    Bagci, Melisa
    Uzel, Esengul Kocak
    Soydemir, Gulsen Pinar
    Figen, Metin
    Bolukbas, Meltem Kirli
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2021, 42 (05) : 936 - 942
  • [47] Comparison of doses to the rectum derived from treatment planning system with in-vivo dose values in vaginal vault brachytherapy using cylinder applicators
    Oyekunle, Emmanuel Oyeyemi
    Obed, Rachel Ibhade
    Akinlade, Bidemi Idayat
    Ntekim, Atara
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (06) : 485 - 491
  • [48] Correlation Between Bladder Volume and Irradiated Dose of Small Bowel in CT-based Planning of Intracavitary Brachytherapy for Cervical Cancer
    Yamashita, Hideomi
    Nakagawa, Keiichi
    Okuma, Kae
    Sakumi, Akira
    Haga, Akihiro
    Kobayashi, Reiko
    Ohtomo, Kuni
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2012, 42 (04) : 302 - 308
  • [49] Dose Volume Histograms (DVH) Analysis and Comparison with ICRU Point Doses in MRI Guided HDR Brachytherapy for Cervical Cancer
    Badkul, R.
    McClinton, C.
    Kumar, P.
    Mitchell, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 348 - 348
  • [50] Propagation of Organ at Risk Contours for High Dose Rate Brachytherapy Planning for Cervical Cancer: A Deformable Image Registration Comparison
    Bellon, M.
    Kumarasiri, A.
    Kim, J.
    Shah, M.
    Elshaikh, M.
    Chetty, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 390 - 390