Comparison of dose volume parameters evaluated using three forward planning - optimization techniques in cervical cancer brachytherapy involving two applicators

被引:10
|
作者
Chakrobarti, Bikramjit [1 ,2 ]
Basu-Roy, Somapriya
Kar, Sanjay Kumar
Das, Sounik
Lahiri, Annesha
机构
[1] Inst Postgrad Med Educ & Res, Dept Radiotherapy, Kolkata 700020, India
[2] Seth Sukhlal Kernani Mem Hosp, Kolkata 700020, India
关键词
cervical cancer; cervix; carcinoma; dosimetry; optimization; INTRACAVITARY BRACHYTHERAPY; AMERICAN BRACHYTHERAPY; COMPUTED-TOMOGRAPHY; MRI; RECOMMENDATIONS; BLADDER; GUIDELINES; CARCINOMA; ANATOMY; TANDEM;
D O I
10.5114/jcb.2017.70677
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study is intended to compare dose-volume parameters evaluated using different forward planning optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose rate (HDR) fractionation schedules. Material and methods: We used tandem-ring and Fletcher-style tandem-ovoid applicator in same patients in two fractions of brachytherapy. Six plans were generated for each patient utilizing 3 forward optimization techniques for each applicator used: equal dwell weight/times ('no optimization'), 'manual dwell weight/times', and 'graphical'. Plans were normalized to left point A and dose of 8 Gy was prescribed. Dose volume and dose point parameters were compared. Results: Without graphical optimization, maximum width and thickness of volume enclosed by 100% isodose line, dose to 90%, and 100% of clinical target volume (CTV); minimum, maximum, median, and average dose to both rectum and bladder are significantly higher with Fletcher applicator. Even if it is done, dose to both points B, minimum dose to CTV, and treatment time; dose to 2 cc (D-2cc) rectum and rectal point etc.; D-2cc, minimum, maximum, median, and average dose to sigmoid colon; D-2cc of bladder remain significantly higher with this applicator. Dose to bladder point is similar (p > 0.05) between two applicators, after all optimization techniques. Conclusions: Fletcher applicator generates higher dose to both CTV and organs at risk (2 cc volumes) after all optimization techniques. Dose restriction to rectum is possible using graphical optimization only during selected HDR fractionation schedules. Bladder always receives dose higher than recommended, and 2 cc sigmoid colon always gets permissible dose. Contrarily, graphical optimization with ring applicators fulfills all dose volume objectives in all HDR fractionations practiced.
引用
收藏
页码:431 / 445
页数:15
相关论文
共 50 条
  • [21] Early Outcomes and Dose-Volume Parameters for CT-Based Treatment Planning in Brachytherapy for Cervical Cancer With Severe Vaginal Invasion or Vaginal Cancer
    Murofushi, K.
    Kitamura, N.
    Yagi, Y.
    Kozuka, T.
    Takeshima, N.
    Sakurai, H.
    Oguchi, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S481 - S481
  • [22] CT-based HDR brachytherapy for cervical cancer: Correlation between dose volume parameters and telangiectasia
    Koom, W.
    Sohn, D.
    Park, S.
    Kim, J.
    Kim, D.
    Shin, K.
    Cho, K.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S400 - S400
  • [23] Direction Modulated Brachytherapy Tandem Model Applicators for Treatment Planning of Multi -Institutional Cervical Cancer Cases: Removing Needles in IntracavitaryInterstitial Techniques
    Manandhar, B.
    Gholami, S.
    Richeson, D.
    Alam, S.
    Gautam, S.
    Scanderbeg, D. J.
    Yashar, C. M.
    Prisciandaro, J. I.
    Jolly, S.
    Fields, E. C.
    Song, W. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E529 - E530
  • [24] 3D PLANNING IN HDR BRACHYTHERAPY OF CERVICAL CANCER: ANALYSIS OF DOSE VOLUME HISTOGRAMS AND CLINICAL CORRELATIONS
    Colombo, A.
    Palmieri, L.
    Frigerio, C.
    Vola, A.
    Rancati, T.
    Sangalli, G.
    Declich, F.
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 : S33 - S33
  • [25] Comparing Non-Invasive High-Dose-Rate Brachytherapy Using Partially-Shielded Applicators to Intracavitary/Interstitial Brachytherapy for Cervical Cancer
    Hopfensperger, K.
    Adams, Q.
    Kim, Y.
    Xu, W.
    Patwardhan, K.
    Thammavong, B.
    Flynn, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E724 - E724
  • [26] Dosimetric comparison of manual forward planning with uniform dwell times versus volume-based inverse planning in interstitial brachytherapy of cervical malignancies
    Palled, Siddanna R.
    Radhakrishna, Nikhila K.
    Manikantan, Senthil
    Khanum, Hashmath
    Venugopal, Bindu K.
    Vishwanath, Lokesh
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (06) : 851 - 855
  • [27] Comparison of two high-dose rate (HDR) brachytherapy regimens in treatment of cervical cancer
    Krishna, A.
    ANNALS OF ONCOLOGY, 2021, 32 : S759 - S759
  • [28] Accurate Dose Volume Parameters Calculation for Revealing Rectum Dose-Toxicity Effect Using Deformable Registration in Cervical Cancer Brachytherapy: A Pilot Study
    Zhen, X.
    Chen, H.
    Liao, Y.
    Zhou, L.
    Hrycushko, B.
    Albuquerque, K.
    Gu, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3458 - 3458
  • [29] Interaction between the Number of Chemotherapy Cycles and Brachytherapy Dose/Volume Parameters in Locally Advanced Cervical Cancer Patients
    Escande, Alexandre
    Khettab, Mohamed
    Bockel, Sophie
    Dumas, Isabelle
    Schernberg, Antoine
    Gouy, Sebastien
    Morice, Philippe
    Pautier, Patricia
    Deutsch, Eric
    Haie-Meder, Christine
    Chargari, Cyrus
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (06)
  • [30] CT based three dimensional dose-volume evaluations for high-dose rate intracavitary brachytherapy for cervical cancer
    Murakami, Naoya
    Kasamatsu, Takahiro
    Wakita, Akihisa
    Nakamura, Satoshi
    Okamoto, Hiroyoki
    Inaba, Koji
    Morota, Madoka
    Ito, Yoshinori
    Sumi, Minako
    Itami, Jun
    BMC CANCER, 2014, 14