Control of a three phase boost rectifier under unbalanced grid conditions without grid voltage sensors

被引:0
|
作者
Mukherjee, Subhajyoti [1 ]
Chowdhury, Vikram Roy [1 ]
Kimball, Jonathan [1 ]
机构
[1] Missouri Univ Sci & Technol, Dept Elect & Comp Engn, Rolla, MO 65409 USA
关键词
Grid connected converter; grid unbalance; positive and negative sequence; voltage estimation; DIRECT POWER-CONTROL; PWM CONVERTER;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a method for estimating the positive and negative sequence grid voltage under unbalanced grid conditions using simple algebraic and trigonometric identities without dedicated grid voltage sensors in three phase grid connected boost rectifier converter system. The estimated voltages are then used to control the positive and negative sequence currents of the boost rectifier. The estimation method is based on the positive and negative sequence active and reactive power delivered by the converter to the grid. In addition to the estimation of the positive and negative sequence grid voltage, the proposed method also generates an estimate of the frequency information of the grid similar to a conventional PLL structure. Detailed theory and results confirm the feasibility of the proposed scheme.
引用
收藏
页码:1521 / 1527
页数:7
相关论文
共 50 条
  • [21] Fault Ride Through Control of Three-phase grid-connected Inverter Under Harmonic and Unbalanced Grid Voltage Conditions
    Guo X.
    Liu W.
    1600, Chinese Society for Electrical Engineering (37): : 5118 - 5124
  • [22] Research of Direct Power Control for PWM Rectifier under Unbalanced Grid Voltage
    Zheng Zheng
    Zhang Zhen-hua
    2013 25TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2013, : 3607 - 3612
  • [23] Direct power control in constant switching frequency for PWM rectifier under unbalanced grid voltage conditions
    Geng, Qiang
    Xia, Changliang
    Yan, Yan
    Chen, Wei
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (36): : 79 - 85
  • [24] Dual-current Loops Control Strategy of PWM Rectifier Under Unbalanced Grid Voltage Conditions
    Ni Yifeng
    Zhu Yongqiang
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 2114 - 2118
  • [25] Model Predictive Control of a Three Phase PWM Boost Rectifier under Extreme Unbalanced Conditions
    Brkovic, Bogdan
    Ristic, Leposava
    Stankovic, Ana
    PROCEEDINGS OF THE 2016 4TH INTERNATIONAL SYMPOSIUM ON ENVIRONMENTAL FRIENDLY ENERGIES AND APPLICATIONS (EFEA), 2016,
  • [26] Control Strategy for Three-Phase Converter under Unbalanced Grid Voltage Conditions Considering Line Loss
    Lee, Kyung-Hwan
    Ha, Jung-Ik
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 5790 - 5796
  • [27] Predictive power control strategy without grid voltage sensors of the Vienna rectifier
    Yang, Tao
    Chen, Lan
    Miao, Yiru
    IET POWER ELECTRONICS, 2024, 17 (11) : 1411 - 1421
  • [28] Control of Three-Phase PWM Rectifier under Unbalanced Input Voltage Conditions without Sequential Component Extraction
    Li, Zixin
    Wang, Ping
    Li, Yaohua
    Zhu, Haibin
    Gao, Fanqiang
    PROCEEDINGS OF 14TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE-PEMC 2010), 2010,
  • [29] Advanced Vector Controller for a Four-Switch Three-Phase Rectifier under Unbalanced Grid Voltage
    Bidgoli, M. Alizadeh
    Honarbari, S.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2022, 2022
  • [30] Robust Tracking Control of a Three-Phase Charger under Unbalanced Grid Conditions
    Choeung, Chivon
    Kry, Meng Leang
    Lee, Young Il
    ENERGIES, 2018, 11 (12)