Fault Ride Through Control of Three-phase grid-connected Inverter Under Harmonic and Unbalanced Grid Voltage Conditions

被引:0
|
作者
Guo X. [1 ]
Liu W. [1 ]
机构
[1] Key Lab of Power Electronics for Energy Conservation and Motor Drive of Hebei Province (College of Electrical Engineering, Yanshan University), Qinhuangdao, 066004, Hebei Province
来源
| 1600年 / Chinese Society for Electrical Engineering卷 / 37期
基金
中国国家自然科学基金;
关键词
Fault recovery; Fault ride through; Grid-connected inverter; Harmonic and unbalanced grid voltage;
D O I
10.13334/j.0258-8013.pcsee.160977
中图分类号
学科分类号
摘要
The grid code requires that the grid-connected inverter inject powers to achieve the voltage recovery during grid faults. However, due to the grid harmonics, the power injection through the line impedance may affect the power quality at the point of common coupling and reduce the system reliability. In order to solve the problem, the relationship between grid harmonics and PCC voltage was analyzed. Then a new voltage recovery control strategy is proposed. It adjusts the control coefficients of positive/negative sequence and harmonics to improve the voltage quality. Finally, the experimental tests of the conventional and proposed control solutions were carried out. The experimental results verified the effectiveness of the proposed method. © 2017 Chin. Soc. for Elec. Eng.
引用
收藏
页码:5118 / 5124
页数:6
相关论文
共 20 条
  • [1] Chidurala A., Kumar Saha T., Mithulananthan N., Harmonic impact of high penetration photovoltaic system on unbalanced distribution networks - learning from an urban photovoltaic network, IET Renewable Power Generation, 10, 4, pp. 485-494, (2016)
  • [2] Zhang X., Yu C., Liu F., Et al., Modeling and resonance analysis of multi-paralleled grid-tied inverters in PV systems, Proceedings of the CSEE, 34, 3, pp. 336-345, (2014)
  • [3] Xu D., Wang F., Mao H., Et al., Modeling and analysis of harmonic interaction between multiple grid- connected inverters and the utility grid, Proceedings of the CSEE, 33, 12, pp. 64-71, (2013)
  • [4] Eloy-Garcia Carrasco J., Tena J.M., Ugena D., Et al., Testing low voltage ride through capabilities of solar inverters, Electric Power Systems Research, 96, pp. 111-118, (2013)
  • [5] Chen Y., Liu J., Zhou J., Fault ride-through control strategy for solar grid-connected inverters, Proceedings of the CSEE, 34, 21, pp. 3405-3412, (2014)
  • [6] Rodriguez P., Timbus A.V., Teodorescu R., Et al., Flexible active power control of distributed power generation systems during grid faults, IEEE Transactions on Industrial Electronics, 54, 5, pp. 2583-2592, (2007)
  • [7] Rodriguez P., Timbus A., Teodorescu R., Et al., Reactive power control for improving wind turbine system behavior under grid faults, IEEE Transactions on Power Electronics, 24, 7, pp. 1798-1801, (2009)
  • [8] Ding M., Wang W., Wang X., Et al., A review on the effect of large-scale PV generation on power systems, Proceedings of the CSEE, 34, 1, pp. 2-14, (2014)
  • [9] Keller J., Kroposki B., Understanding fault characteristics of inverter-based distributed energy resources, (2010)
  • [10] Mohamed Y.A.R.I., El-Saadany E.F., A control method of grid-connected PWM voltage source inverters to mitigate fast voltage disturbances, IEEE Transactions on Power Systems, 24, 1, pp. 489-491, (2009)