Design and test of the CMS pixel readout chip

被引:30
|
作者
Barbero, M
Bertl, W
Dietrich, G
Dorokhov, A
Erdmann, W
Gabathuler, K [1 ]
Heising, S
Hörmann, C
Horisberger, R
Kästli, HC
Kotlinski, D
Meier, B
Weber, R
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] Univ Basel, Inst Phys, CH-4056 Basel, Switzerland
[3] Univ Zurich, Inst Phys, CH-8057 Zurich, Switzerland
[4] ETH, Int Teilchenphys, CH-8093 Zurich, Switzerland
关键词
CMS; pixel detector; readout chip; design; data loss measured;
D O I
10.1016/j.nima.2003.09.043
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The readout chip for the CMS pixel detector must handle an enormous flux of data, while keeping the data loss at a minimum. Full size prototype readout chips bump-bonded to sensors have been tested in a pion beam simulating an LHC-like environment, and the data loss as a function of particle fluence has been measured. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:349 / 359
页数:11
相关论文
共 50 条
  • [21] The control and readout systems of the CMS pixel barrel detector
    Kotlinski, D.
    Bartz, E.
    Erdmann, W.
    Gabathuler, K.
    Horisberger, R.
    Hoermann, Ch.
    Kaestli, H.-Ch.
    Meier, B.
    Schnetzer, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (01): : 73 - 78
  • [22] CMS pixel detector with new digital readout architecture
    Meier, B.
    [J]. JOURNAL OF INSTRUMENTATION, 2011, 6
  • [23] The MGPA electromagnetic calorimeter readout chip for CMS
    Raymond, M
    Crooks, J
    French, M
    Hall, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 756 - 763
  • [24] The MGPA electromagnetic calorimeter readout chip for CMS
    Raymond, M
    Crooks, J
    French, M
    Hall, G
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 156 - 160
  • [25] A High Frame Rate Pixel Readout Chip Design for Synchrotron Radiation Applications
    Wei, Wei
    Zhang, Jie
    Ning, Zhe
    Lu, Yunpeng
    Fan, Lei
    Li, Huaishen
    Jiang, Xiaoshan
    Lan, Allan K.
    Ouyang, Qun
    Wang, Zheng
    Zhu, Kejun
    Chen, Yuanbo
    Liu, Peng
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [26] Analog performance of the CROCv1 pixel readout chip for the CMS Phase-2 Tracker Upgrade
    Papadopouloson, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2023, 18 (01)
  • [27] A counting pixel readout chip for imaging applications
    Fischer, P
    Hausmann, J
    Overdick, M
    Raith, B
    Wermes, N
    Blanquart, L
    Bonzom, V
    Delpierre, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 405 (01): : 53 - 59
  • [28] A digital readout system for the CMS Phase I Pixel Upgrade
    Stringer, R.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [29] The CMS binary chip for microstrip tracker readout at the SLHC
    Raymond, M.
    Braga, D.
    Ferguson, W.
    Fulcher, J.
    Hall, G.
    Jacob, J.
    Jones, L.
    Pesaresi, M.
    Prydderch, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2012, 7
  • [30] Single event effects in the pixel readout chip for BTeV
    Chiodini, G
    Appel, JA
    Cardoso, G
    Christian, DC
    Coluccia, MR
    Hoff, J
    Kwan, SW
    Mekkaoui, A
    Yarema, R
    Zimmermann, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (01): : 183 - 188