Modeling seismic response of a full-scale cold-formed steel-framed building

被引:48
|
作者
Leng, Jiazhen [1 ]
Peterman, Kara D. [1 ]
Bian, Guanbo [1 ]
Buonopane, Stephen G. [2 ]
Schafer, Benjamin W. [1 ]
机构
[1] Johns Hopkins Univ, Dept Civil Engn, Baltimore, MD 21218 USA
[2] Bucknell Univ, Dept Civil & Environm Engn, Lewisburg, PA 17837 USA
基金
美国国家科学基金会;
关键词
Cold-formed steel; Finite element modeling; OpenSees; Shear walls; Gravity framing; Nonstructural components; Shaking table test;
D O I
10.1016/j.engstruct.2017.10.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this paper is to present finite element modeling protocols and validation studies for the seismic response of a two-story cold-formed steel-framed building with oriented strand board sheathed shear walls. Recently, shake table testing of this building was completed by the authors. The building provides an archetype for modern details of cold-formed steel construction, and provides benchmarks for the seismic response of the building system, subsystem, and components. The seismic response of buildings framed from cold-formed steel has seen little study in comparison with efforts on isolated members and shear walls. Validated building-scale models are needed to expand our understanding of the seismic response of these systems. Finite element models corresponding to the archetype building during its various test phases are developed in OpenSees and detailed herein. For cold-formed steel framed buildings accurate seismic models require consideration of components beyond the isolated shear walls, e.g. the stiffness and capacity of the gravity framing is included in the model. Such decisions require model refinement beyond what is typically performed and details for completing this effort accurately and efficiently are described herein. In addition, nonstructural components, including exterior sheathing of the gravity framing, interior gypsum sheathing for the shear walls and gravity framing, and interior partition walls, are included in the building model based on nonlinear surrogate models that utilize experimental characterization of member-fastener-sheathing response. Comparisons between the developed models and testing for natural period, story drift, accelerations, and foundation hold-down forces validate the model. Performance of the tested archetype building is better than predicted by design or typical engineering assumptions. The model developed herein provides insights into how the building achieves its beneficial performance and will be used to further quantify the lateral resistance of each subsystem and the extent of their coupling. In addition, the protocols used to develop the model herein provide a first examination of the necessary modeling characteristics for wider archetype studies of cold-formed steel-framed buildings and the development and substantiation of seismic response modification coefficients. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:146 / 165
页数:20
相关论文
共 50 条
  • [31] Seismic performance of cold-formed steel framed shear walls with steel sheathing and gypsum board
    Feng, Ruo-qiang
    Zhu, Baochen
    Xu, PengHui
    Qiu, Yun
    [J]. THIN-WALLED STRUCTURES, 2019, 143
  • [32] Earthquake and Postearthquake Fire Testing of a Midrise Cold-Formed Steel-Framed Building. II: Shear Wall Behavior and Design Implications
    Wang, Xiang
    Hutchinson, Tara C.
    [J]. Journal of Structural Engineering (United States), 2021, 147 (09):
  • [33] Dynamic and cyclic response of a full-scale 2-storey cold-formed steel structure with and without infill materials
    Senkardesler, O.
    Goler, G.
    Soyoz, S.
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2017, 15 (08) : 3207 - 3226
  • [34] Lateral Resistance Reduction to Cold-Formed Steel-Framed Shear Walls under Various Fire Scenarios
    Hoehler, Matthew S.
    Andres, Blanca
    Bund, Matthew F.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (05)
  • [35] Development of the simplified spring-based nonlinear models for full-connection cold-formed steel-framed gypsum partition walls
    Lotfy, Iraj
    Salkhordeh, Mojtaba
    Soroushian, Siavash
    Rahmanishamsi, Esmaeel
    Maragakis, Emmanuel M.
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2023, 52 (05): : 1317 - 1338
  • [36] Earthquake and Postearthquake Fire Testing of a Midrise Cold-Formed Steel-Framed Building. II: Shear Wall Behavior and Design Implications
    Wang, Xiang
    Hutchinson, Tara C.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (09)
  • [37] Progressive collapse of cold-formed steel framed structures
    Bae, Sang-Wook
    LaBoube, Roger A.
    Belarbi, Abdeldjelil
    Ayoub, Ashraf
    [J]. THIN-WALLED STRUCTURES, 2008, 46 (7-9) : 706 - 719
  • [38] Cold-Formed Steel Framed Gypsum Shear Walls: In-Plane Response
    Peck, Q.
    Rogers, N.
    Serrette, R.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2012, 138 (07) : 932 - 941
  • [39] FULL-SCALE TESTS ON COLD-FORMED STEEL PITCHED-ROOF PORTAL FRAMES WITH BOLTED JOINTS
    Dubina, D.
    Stratan, A.
    Nagy, Zs.
    [J]. ADVANCED STEEL CONSTRUCTION, 2009, 5 (02): : 175 - 194
  • [40] Fire performance of superabsorbent polymers protected full-scale cold-formed steel wall lined with plasterboards
    Liu, Kang
    Chen, Wei
    Ye, Jihong
    Jiang, Jian
    Fang, Zhiyuan
    Lim, James B. P.
    [J]. THIN-WALLED STRUCTURES, 2024, 204