Fire performance of superabsorbent polymers protected full-scale cold-formed steel wall lined with plasterboards

被引:0
|
作者
Liu, Kang [1 ,2 ,3 ]
Chen, Wei [1 ,2 ]
Ye, Jihong [1 ,2 ]
Jiang, Jian [1 ,2 ]
Fang, Zhiyuan [3 ]
Lim, James B. P. [3 ]
机构
[1] China Univ Min & Technol, Jiangsu Key Lab Environm Impact & Struct Safety En, Xuzhou 221116, Peoples R China
[2] China Univ Min & Technol, Xuzhou Key Lab Fire Safety Engn Struct, Xuzhou 221116, Peoples R China
[3] Univ Waikato, Sch Engn, Hamilton 3216, New Zealand
基金
中国国家自然科学基金;
关键词
Superabsorbent polymer insulation material; Fire tests; Hot flange width-to-thickness ratio; Stud web depth; Cold-formed steel; BEHAVIOR; COLLAPSE;
D O I
10.1016/j.tws.2024.112353
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Superabsorbent polymers (SAPs) have shown promise in enhancing the fire resistance of steel structures because of their exceptional absorbency and water retention capabilities. This study innovatively applies SAP insulation to cold-formed steel (CFS) walls with gypsum (GP) boards to improve fire performance. One full-scale CFS wall underwent axial compression testing at ambient temperature, and four full-scale fire experiments were conducted on CFS walls with load ratios of 0.27 and 0.85. All specimens were sheathed with double layers of GP boards, and rock wool served as the cavity insulation, with SAP insulation material applied to the cavity of wall studs. Additionally, a novel finite element model was developed to simulate the fluid-heat interaction within a furnace-CFS wall. The simulation results showed that SAP insulation material significantly changes the fireinduced failure mode in wall studs at a 0.27 load ratio, transitioning from hot flange (HF) local buckling to local buckling of the whole stud section. The inclusion of SAP insulation material absorbs heat, effectively delaying the rise in wall stud temperature. This property significantly enhances the structural performance of CFS walls during fire exposure. With SAP insulation material, the fire resistance time of the CFS walls increased by over 66 min compared to non-SAP insulation material counterparts. Moreover, increasing the stud web depth and reducing the HF width-to-thickness ratio can enhance the fire performance of CFS walls. The HF critical failure temperature of specimen S2 with an HF width-to-thickness ratio of 80 was 783 degrees C, 150 degrees C higher than that of specimen P2 with an HF width-to-thickness ratio of 67. Additionally, the adverse effect of screws on the fire performance of the CFS wall was localized. After 120 min of fire exposure, the temperature on the ambient side, which was severely influenced by the screws, was 360 to 370 degrees C.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Seismic Performance of Cold-Formed Steel Wall Systems in a Full-Scale Building
    Wang, X.
    Pantoli, E.
    Hutchinson, T. C.
    Restrepo, J. I.
    Wood, R. L.
    Hoehler, M. S.
    Grzesik, P.
    Sesma, F. H.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (10)
  • [2] Full-scale fire experiments on load-bearing cold-formed steel walls lined with different panels
    Chen, Wei
    Ye, Jihong
    Bai, Yu
    Zhao, Xiao-Ling
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 79 : 242 - 254
  • [3] Influence of different gypsum plasterboards on the fire performance of cold-formed steel walls
    Liu, Kang
    Chen, Wei
    Ye, Jihong
    Ma, Jianyue
    Jiang, Jian
    [J]. STRUCTURES, 2022, 46 : 159 - 171
  • [4] Fire performance of superabsorbent polymers protecting cold-formed steel walls with high load ratios
    Chen, Wei
    Liu, Kang
    Ye, Jihong
    Jiang, Jian
    [J]. THIN-WALLED STRUCTURES, 2022, 181
  • [5] Experimental study on fire resistance of full-scale cold-formed steel composite shear wall structure under real fire conditions
    Ye, Jihong
    Chen, Wenwen
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (06): : 59 - 71
  • [6] Postearthquake fire experiments of cavity-insulated cold-formed steel load-bearing walls lined with plasterboards
    Chen, Wei
    Ye, Jihong
    Wang, Qiang
    Jiang, Jian
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 167
  • [7] Full-scale test behavior of cold-formed steel roof trusses
    Wood, JV
    Dawe, JL
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2006, 132 (04) : 616 - 623
  • [8] Behaviour of cold-formed steel wall frames lined with plasterboard
    Telue, Y
    Mahendran, M
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (04) : 435 - 452
  • [9] Investigation on fire experiments of full-scale load-bearing cold-formed steel walls with insulation configuration
    Chen, Wei
    Liu, Kang
    Ye, Jihong
    Yin, Liang
    Jiang, Jian
    Qin, Yafei
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (10): : 146 - 155
  • [10] Testing, modelling and analysis of full-scale cold-formed steel center-sheathed shear walls in fire
    Xing, Yonghui
    Zhao, Ou
    Wang, Weiyong
    [J]. ENGINEERING STRUCTURES, 2023, 284