Impact of Model-Based Iterative Reconstruction on Image Quality of Contrast-Enhanced Neck CT

被引:20
|
作者
Gaddikeri, S. [1 ]
Andre, J. B. [1 ]
Benjert, J. [2 ]
Hippe, D. S. [3 ]
Anzai, Y. [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Neuroradiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Neuroradiol, Seattle, WA 98195 USA
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
FILTERED BACK-PROJECTION; MULTIDETECTOR ROW CT; COMPUTED-TOMOGRAPHY; DOSE REDUCTION; RADIATION-EXPOSURE; HELICAL CT; OPTIMIZATION; STRATEGIES; 64-MDCT; CANCER;
D O I
10.3174/ajnr.A4123
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Improved image quality is clinically desired for contrast-enhanced CT of the neck. We compared 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction algorithms for the assessment of image quality of contrast-enhanced CT of the neck. MATERIALS AND METHODS: Neck contrast-enhanced CT data from 64 consecutive patients were reconstructed retrospectively by using 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction. Objective image quality was assessed by comparing SNR, contrast-to-noise ratio, and background noise at levels 1 (mandible) and 2 (superior mediastinum). Two independent blinded readers subjectively graded the image quality on a scale of 1-5, (grade 5 = excellent image quality without artifacts and grade 1 = nondiagnostic image quality with significant artifacts). The percentage of agreement and disagreement between the 2 readers was assessed. RESULTS: Compared with 30% adaptive statistical iterative reconstruction, model-based iterative reconstruction significantly improved the SNR and contrast-to-noise ratio at levels 1 and 2. Model-based iterative reconstruction also decreased background noise at level] (P = .016), though there was no difference at level 2 (P = .61). Model-based iterative reconstruction was scored higher than 30% adaptive statistical iterative reconstruction by both reviewers at the nasopharynx (P < .001) and oropharynx (P < .001) and for overall image quality (P < .001) and was scored lower at the vocal cords (P < .001) and sternoclavicular junction (P < .001), due to artifacts related to thyroid shielding that were specific for model-based iterative reconstruction. CONCLUSIONS: Model-based iterative reconstruction offers improved subjective and objective image quality as evidenced by a higher SNR and contrast-to-noise ratio and lower background noise within the same dataset for contrast-enhanced neck CT. Model-based iterative reconstruction has the potential to reduce the radiation dose while maintaining the image quality, with a minor downside being prominent artifacts related to thyroid shield use on model-based iterative reconstruction.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 50 条
  • [1] Model-based Iterative CT Image Reconstruction on GPUs
    Sabne, Amit
    Wang, Xiao
    Kisner, Sherman
    Bouman, Charles
    Raghunathan, Anand
    Midkiff, Samuel
    ACM SIGPLAN NOTICES, 2017, 52 (08) : 207 - 220
  • [2] Improving image quality with model-based iterative reconstruction algorithm for chest CT in children with reduced contrast concentration
    Jihang Sun
    Di Hu
    Yun Shen
    Haiming Yang
    Chenghao Chen
    Jie Yin
    Yun Peng
    La radiologia medica, 2019, 124 : 595 - 601
  • [3] Improving image quality with model-based iterative reconstruction algorithm for chest CT in children with reduced contrast concentration
    Sun, Jihang
    Hu, Di
    Shen, Yun
    Yang, Haiming
    Chen, Chenghao
    Yin, Jie
    Peng, Yun
    RADIOLOGIA MEDICA, 2019, 124 (07): : 595 - 601
  • [4] Advanced Modeled Iterative Reconstruction in Low-Tube-Voltage Contrast-Enhanced Neck CT: Evaluation of Objective and Subjective Image Quality
    Scholtz, J. -E.
    Kaup, M.
    Huesers, K.
    Albrecht, M. H.
    Bodelle, B.
    Metzger, S. C.
    Kerl, J. M.
    Bauer, R. W.
    Lehnert, T.
    Vogl, T. J.
    Wichmann, J. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (01) : 143 - 150
  • [5] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    S. Notohamiprodjo
    Z. Deak
    F. Meurer
    F. Maertz
    F. G. Mueck
    L. L. Geyer
    S. Wirth
    European Radiology, 2015, 25 : 140 - 146
  • [6] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    Notohamiprodjo, S.
    Deak, Z.
    Meurer, F.
    Maertz, F.
    Mueck, F. G.
    Geyer, L. L.
    Wirth, S.
    EUROPEAN RADIOLOGY, 2015, 25 (01) : 140 - 146
  • [7] Initial Evaluation of Model-Based Iterative CT Reconstruction Using Standard Image Quality Phantoms
    Gingold, E.
    Dave, J.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [8] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Bharti Kataria
    Jonas Nilsson Althén
    Örjan Smedby
    Anders Persson
    Hannibal Sökjer
    Michael Sandborg
    European Radiology, 2018, 28 : 2464 - 2473
  • [9] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Kataria, Bharti
    Althen, Jonas Nilsson
    Smedby, Orjan
    Persson, Anders
    Sokjer, Hannibal
    Sandborg, Michael
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2464 - 2473
  • [10] Impact of Statistical Weights On Detection of Low-Contrast Details in Model-Based Iterative CT Reconstruction
    Noo, F.
    Guo, Z.