Impact of Model-Based Iterative Reconstruction on Image Quality of Contrast-Enhanced Neck CT

被引:20
|
作者
Gaddikeri, S. [1 ]
Andre, J. B. [1 ]
Benjert, J. [2 ]
Hippe, D. S. [3 ]
Anzai, Y. [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Neuroradiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Neuroradiol, Seattle, WA 98195 USA
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
FILTERED BACK-PROJECTION; MULTIDETECTOR ROW CT; COMPUTED-TOMOGRAPHY; DOSE REDUCTION; RADIATION-EXPOSURE; HELICAL CT; OPTIMIZATION; STRATEGIES; 64-MDCT; CANCER;
D O I
10.3174/ajnr.A4123
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Improved image quality is clinically desired for contrast-enhanced CT of the neck. We compared 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction algorithms for the assessment of image quality of contrast-enhanced CT of the neck. MATERIALS AND METHODS: Neck contrast-enhanced CT data from 64 consecutive patients were reconstructed retrospectively by using 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction. Objective image quality was assessed by comparing SNR, contrast-to-noise ratio, and background noise at levels 1 (mandible) and 2 (superior mediastinum). Two independent blinded readers subjectively graded the image quality on a scale of 1-5, (grade 5 = excellent image quality without artifacts and grade 1 = nondiagnostic image quality with significant artifacts). The percentage of agreement and disagreement between the 2 readers was assessed. RESULTS: Compared with 30% adaptive statistical iterative reconstruction, model-based iterative reconstruction significantly improved the SNR and contrast-to-noise ratio at levels 1 and 2. Model-based iterative reconstruction also decreased background noise at level] (P = .016), though there was no difference at level 2 (P = .61). Model-based iterative reconstruction was scored higher than 30% adaptive statistical iterative reconstruction by both reviewers at the nasopharynx (P < .001) and oropharynx (P < .001) and for overall image quality (P < .001) and was scored lower at the vocal cords (P < .001) and sternoclavicular junction (P < .001), due to artifacts related to thyroid shielding that were specific for model-based iterative reconstruction. CONCLUSIONS: Model-based iterative reconstruction offers improved subjective and objective image quality as evidenced by a higher SNR and contrast-to-noise ratio and lower background noise within the same dataset for contrast-enhanced neck CT. Model-based iterative reconstruction has the potential to reduce the radiation dose while maintaining the image quality, with a minor downside being prominent artifacts related to thyroid shield use on model-based iterative reconstruction.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 50 条
  • [31] Physical and visual evaluations of CT image quality of large low-contrast objects with visual model-based iterative reconstruction technique: a phantom study
    Shibata, Hideki
    Matsubara, Kosuke
    Asada, Yasuki
    Takemura, Akihiro
    Kozawa, Isao
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (01) : 141 - 150
  • [32] Physical and visual evaluations of CT image quality of large low-contrast objects with visual model-based iterative reconstruction technique: a phantom study
    Hideki Shibata
    Kosuke Matsubara
    Yasuki Asada
    Akihiro Takemura
    Isao Kozawa
    Physical and Engineering Sciences in Medicine, 2023, 46 : 141 - 150
  • [33] Model-Based Pancreas Segmentation in Portal Venous Phase Contrast-Enhanced CT Images
    Matthias Hammon
    Alexander Cavallaro
    Marius Erdt
    Peter Dankerl
    Matthias Kirschner
    Klaus Drechsler
    Stefan Wesarg
    Michael Uder
    Rolf Janka
    Journal of Digital Imaging, 2013, 26 : 1082 - 1090
  • [34] Model-Based Pancreas Segmentation in Portal Venous Phase Contrast-Enhanced CT Images
    Hammon, Matthias
    Cavallaro, Alexander
    Erdt, Marius
    Dankerl, Peter
    Kirschner, Matthias
    Drechsler, Klaus
    Wesarg, Stefan
    Uder, Michael
    Janka, Rolf
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (06) : 1082 - 1090
  • [35] Contrast-enhanced spiral CT of the head and neck
    Ginsberg, LE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (07) : 1365 - 1365
  • [36] Usefulness of Model-Based Iterative Reconstruction in Brain CT as Compared With Hybrid Iterative Reconstruction
    Sekino, Hirofumi
    Ishii, Shiro
    Kuroiwa, Daichi
    Fujimaki, Hideki
    Sugawara, Shigeyasu
    Suenaga, Hiroki
    Hakozaki, Motoharu
    Yamakuni, Ryo
    Watanabe, Hirotake
    Hasegawa, Osamu
    Ito, Hiroshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (04) : 600 - 605
  • [37] Automated Assessment of Image Sharpness Degradation in Iterative CT Reconstruction Techniques: Vessel-Sharpness in Contrast-Enhanced Liver
    Chun, M.
    Jin, H.
    Kim, S.
    Jeong, W. K.
    Heo, C.
    Kim, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [38] Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis
    Frédéric A. Miéville
    Laureline Berteloot
    Albane Grandjean
    Paul Ayestaran
    François Gudinchet
    Sabine Schmidt
    Francis Brunelle
    François O. Bochud
    Francis R. Verdun
    Pediatric Radiology, 2013, 43 : 558 - 567
  • [39] Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis
    Mieville, Frederic A.
    Berteloot, Laureline
    Grandjean, Albane
    Ayestaran, Paul
    Gudinchet, Francois
    Schmidt, Sabine
    Brunelle, Francis
    Bochud, Francois O.
    Verdun, Francis R.
    PEDIATRIC RADIOLOGY, 2013, 43 (05) : 558 - 567
  • [40] Full model-based iterative reconstruction (MBIR) in abdominal CT increases objective image quality, but decreases subjective acceptance
    Laurent, Gautier
    Villani, Nicolas
    Hossu, Gabriela
    Rauch, Aymeric
    Noel, Alain
    Blum, Alain
    Teixeira, Pedro Augusto Gondim
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 4016 - 4025