Partial Volume Correction Using Continuous Wavelet Technique in Small Animal PET Imaging

被引:1
|
作者
Arhjoul, Lahcen [1 ]
Sarrhini, Otman [1 ]
Bentourkia, M'hamed [1 ]
机构
[1] Univ Sherbrooke, Dept Nucl Med & Radiobiol, Fac Med & Hlth Sci, Sherbrooke, PQ J1H 5N4, Canada
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
D O I
10.1109/NSSMIC.2006.356441
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The underestimation of the emitted radioactivity in small tissue structures measured with PET unfortunately requires correction for the partial volume effect (PVE) prior to image analysis. Meanwhile, the continuous wavelet transform (CWT) has the potential to isolate the signal of small structures from their environments, and to determine each structure by its width and position in PET images. Using CWT analysis and recovery coefficients (RC), we report a new approach to correct for PVE in phantom and in rat PET images, regardless of the shape of the structures. The results show a full recovery in image intensity in the phantom small hot spots, and similarly in the rat tumors without any additional noise. On the other hand, dynamic FDG-PET was performed in rat images before and after PVE correction to assess tumor metabolic rates of glucose (MRG). The MRG values after PVE correction were significantly increased by 2.2 and 2.1 mu moles/100g/min for right and left tumors respectively, compared to those before PVE correction.
引用
收藏
页码:2717 / 2721
页数:5
相关论文
共 50 条
  • [41] Small animal tumour imaging with MRI and the ECAT EXACT scanner: application of partial volume correction and comparison with microPET data
    Helisch, Andreas
    Thews, Oliver
    Buchholz, Hans-Georg
    Tillmanns, Julia
    Kronfeld, Andrea
    Schreiber, Laura M.
    Schreckenberger, Mathias
    Bartenstein, Peter
    NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (04) : 294 - 300
  • [42] Design of a small animal PET imaging system with 1 microliter volume resolution
    Rouze, NC
    Schmand, M
    Siegel, S
    Hutchins, GD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 757 - 763
  • [43] Design of a small animal PET imaging system with 1 microliter volume resolution
    Rouze, NC
    Schmand, M
    Siegel, S
    Hutchins, GD
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2067 - 2071
  • [44] PET quantification: Strategies for partial volume correction
    Bettinardi V.
    Castiglioni I.
    De Bernardi E.
    Gilardi M.C.
    Clinical and Translational Imaging, 2014, 2 (3) : 199 - 218
  • [45] Scatter Characterization and Correction for Simultaneous Multiple Small-Animal PET Imaging
    Rameshwar Prasad
    Habib Zaidi
    Molecular Imaging and Biology, 2014, 16 : 199 - 209
  • [46] Scatter Characterization and Correction for Simultaneous Multiple Small-Animal PET Imaging
    Prasad, Rameshwar
    Zaidi, Habib
    MOLECULAR IMAGING AND BIOLOGY, 2014, 16 (02) : 199 - 209
  • [47] Molecular imaging of biochemical functions using (small animal) pet
    Schubiger, A.
    CALCIFIED TISSUE INTERNATIONAL, 2008, 82 : S22 - S22
  • [48] Fully automated partial volume correction in PET based on a wavelet approach without the use of anatomical information
    Boussion, N.
    Hatt, M.
    Reilhac, A.
    Visvikis, D.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2812 - +
  • [49] Applications of Small Animal Imaging with PET, PET/CT, and PET/MR Imaging
    Nanni, Cristina
    Torigian, Drew A.
    PET CLINICS, 2008, 3 (03) : 243 - +
  • [50] Attenuation correction for small animal PET tomographs
    Chow, PL
    Rannou, FR
    Chatziioannou, AF
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08): : 1837 - 1850