Partial Volume Correction Using Continuous Wavelet Technique in Small Animal PET Imaging

被引:1
|
作者
Arhjoul, Lahcen [1 ]
Sarrhini, Otman [1 ]
Bentourkia, M'hamed [1 ]
机构
[1] Univ Sherbrooke, Dept Nucl Med & Radiobiol, Fac Med & Hlth Sci, Sherbrooke, PQ J1H 5N4, Canada
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
D O I
10.1109/NSSMIC.2006.356441
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The underestimation of the emitted radioactivity in small tissue structures measured with PET unfortunately requires correction for the partial volume effect (PVE) prior to image analysis. Meanwhile, the continuous wavelet transform (CWT) has the potential to isolate the signal of small structures from their environments, and to determine each structure by its width and position in PET images. Using CWT analysis and recovery coefficients (RC), we report a new approach to correct for PVE in phantom and in rat PET images, regardless of the shape of the structures. The results show a full recovery in image intensity in the phantom small hot spots, and similarly in the rat tumors without any additional noise. On the other hand, dynamic FDG-PET was performed in rat images before and after PVE correction to assess tumor metabolic rates of glucose (MRG). The MRG values after PVE correction were significantly increased by 2.2 and 2.1 mu moles/100g/min for right and left tumors respectively, compared to those before PVE correction.
引用
收藏
页码:2717 / 2721
页数:5
相关论文
共 50 条
  • [31] Small animal PET imaging
    Miller, MA
    Rouze, NC
    Hutchins, GD
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 381 - 390
  • [32] Partial Volume Correction for Subregional Analysis of Striatal Uptake in Dopaminergic PET Imaging
    Lue, K. H.
    Lin, H. H.
    Kao, C. H.
    Hsieh, H. J.
    Liu, S. H.
    Chuang, K. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S346 - S346
  • [33] Objective evaluation of voxelwise partial volume correction methods in brain PET imaging
    Bilgel, Murat
    Zhu, Yansong
    Rousset, Olivier
    Wong, Dean
    Resnick, Susan
    Rahmim, Arman
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [34] Diffpvc: A Conditional Diffusion Model for Partial Volume Correction in Brain PET Imaging
    Sun, Y.
    Mawlawi, O. R.
    MEDICAL PHYSICS, 2024, 51 (10) : 7894 - 7894
  • [35] Validations for MR-based partial volume correction for brain PET imaging
    Matsubara, Keisuke
    Ibaraki, Masanobu
    Maeda, Tetsuya
    Kinoshita, Toshibumi
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [36] Partial volume effect estimation and correction in the aortic vascular wall in PET imaging
    Burg, S.
    Dupas, A.
    Stute, S.
    Dieudonne, A.
    Huet, P.
    Le Guludec, D.
    Buvat, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : 7527 - 7542
  • [37] Wavelet-based partial volume effect correction for simultaneous MR/PET of the carotid arteries
    Jason Bini
    Mootaz Eldib
    Philip M Robson
    Zahi A Fayad
    EJNMMI Physics, 1 (Suppl 1)
  • [38] Characterisation of partial volume effect and region-based correction in small animal positron emission tomography (PET) of the rat brain
    Lehnert, Wencke
    Gregoire, Marie-Claude
    Reilhac, Anthonin
    Meikle, Steven R.
    NEUROIMAGE, 2012, 60 (04) : 2144 - 2157
  • [39] A Comparison of the Options for Brain Partial Volume Correction Using PET/MRI
    Thomas, Benjamin A.
    Erlandsson, Kjell
    Reilhac, Anthonin
    Bousse, Alexandre
    Kazantsev, Daniil
    Pedemonte, Stefano
    Vunckx, Kathleen
    Arridge, Simon
    Ourselin, Sebastien
    Hutton, Brian F.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2902 - 2906
  • [40] Determination of Tumor Volume Using a Joint Motion-PVE Correction Technique in PET/CT Imaging
    Chang, G.
    Chang, T.
    Clark, J.
    Mawlawi, O.
    MEDICAL PHYSICS, 2010, 37 (06)