A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

被引:5
|
作者
Iturrate, Mikel [1 ]
Lizundia, Erlantz [2 ,3 ]
Amezua, Xabier [4 ]
Solaberrieta, Eneko [4 ]
机构
[1] Univ Basque Country, Gipuzkoa Fac Engn, Dept Business Management, UPV EHU, Donostia San Sebastian, Spain
[2] Univ Basque Country, Bilbao Fac Engn, Dept Graph Design & Engn Projects, UPV EHU, Bilbao, Spain
[3] Univ Basque Country, BCMat, Basque Ctr Mat Applicat & Nanostruct, Leioa, Spain
[4] Univ Basque Country, Dept Graph Design & Engn Projects, Gipuzkoa Fac Engn, UPV EHU, Donostia San Sebastian, Spain
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2019年 / 11卷 / 06期
关键词
Intraoral scanner; Accuracy; Trueness; Digital impression; Computer-aided design and computer-aided manufacturing (CAD/CAM); IN-VIVO PRECISION; DIGITAL IMPRESSIONS; CONVENTIONAL IMPRESSIONS; CLINICAL-EVALUATION; FIT; EFFICIENCY; VITRO; TIME; IMPLANTS; CASTS;
D O I
10.4047/jap.2019.11.6.331
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (alpha=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with Hero Element1 (mean from 10 +/- 7 mu m to 91 +/- 63 mu m) while the worst values were obtained with Trios3 (mean from 42 +/- 23 mu m to 174 +/- 77 mu m). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Elementl was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.
引用
收藏
页码:331 / 340
页数:10
相关论文
共 50 条
  • [1] Complete-arch accuracy of intraoral scanners
    Treesh, Joshua C.
    Liacouras, Peter C.
    Taft, Robert M.
    Brooks, Daniel, I
    Raiciulescu, Sorana
    Ellert, Daniel O.
    Grant, Gerald T.
    Ye, Ling
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 382 - 388
  • [2] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    [J]. HEALTHCARE, 2021, 9 (03)
  • [3] Accuracy of Five Intraoral Scanners and Two Laboratory Scanners for a Complete Arch: A Comparative In Vitro Study
    Kang, Byung-hyun
    Son, Keunbada
    Lee, Kyu-bok
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [4] Accuracy of intraoral scanners in different complete arch scan patterns
    Pattamavilai, Sakaorat
    Ongthiemsak, Chakree
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 155 - 162
  • [5] Complete-arch accuracy of seven intraoral scanners measured by the virtual-fit method
    Borbola, Daniel
    Mikolicz, Akos
    Romanszky, Laszlo
    Sersli, Gyorgy
    DeFee, Michael
    Renne, Walter
    Vag, Janos
    [J]. JOURNAL OF DENTISTRY, 2024, 149
  • [6] Accuracy of full-arch scans using intraoral and extraoral scanners: an in vitro study using a new method of evaluation
    Muallah, J.
    Wesemann, C.
    Nowak, R.
    Robben, J.
    Mah, J.
    Pospiech, P.
    Bumann, A.
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (02) : 151 - 164
  • [7] Accuracy of 9 intraoral scanners for complete-arch image acquisition: A qualitative and quantitative evaluation
    Kim, Ryan Jin-Young
    Park, Ji-Man
    Shim, June-Sung
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (06): : 895 - +
  • [8] Accuracy of full-arch scans using intraoral scanners
    Patzelt, Sebastian B. M.
    Emmanouilidi, Archontia
    Stampf, Susanne
    Strub, Joerg R.
    Att, Wael
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1687 - 1694
  • [9] Accuracy of full-arch scans using intraoral scanners
    Sebastian B. M. Patzelt
    Archontia Emmanouilidi
    Susanne Stampf
    Joerg R. Strub
    Wael Att
    [J]. Clinical Oral Investigations, 2014, 18 : 1687 - 1694
  • [10] Effect of different arch widths on the accuracy of three intraoral scanners
    Kaewbuasa, Narin
    Ongthiemsak, Chakree
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (04): : 205 - 215