Digital Planning Software Fails to Reflect Stem Torsion on Plain Radiographs after Total Hip Arthroplasty

被引:5
|
作者
Worlicek, M. [1 ]
Weber, M. [1 ]
Zeman, F. [2 ]
Woerner, M. [1 ]
Schneider, M. [1 ]
Grifka, J. [1 ]
Renkawitz, T. [1 ]
Craiovan, B. [1 ]
机构
[1] Univ Regensburg, Dept Orthoped Surg, Kaiser Karl V Allee 3, D-93077 Bad Abbach, Germany
[2] Univ Regensburg, Ctr Clin Studies, Regensburg, Germany
关键词
hip arthroplasty; stem version; anterior posterior radiographs; planning software; CT; FEMORAL OFFSET; REPLACEMENT; ANTEVERSION; IMPINGEMENT; VERSION; MOTION; RANGE;
D O I
10.1055/s-0042-106975
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the validity of commercially available planning software on plain radiographs after THA compared to CT scans as the gold standard. Patients and Methods: In a prospective clinical study, anteroposterior (AP) radiographs and three-dimensional CT scans (3D-CT) were obtained for 121 patients, who underwent minimally invasive, cementless THA with a straight tapered stem, in a lateral decubitus position. For measuring SV, we used digital planning software (TraumaCad 2.0, BrainLAB Feldkirchen, Germany). Two independent raters repeated the analysis after a six-week interval. Radiological measurements were compared with 3D-CT measurements by an independent, blinded external institute. This investigation was approved by the local ethics commission (no. 10 - 121-0263) and is a secondary analysis of a larger project (DRKS00 000 739, German Clinical Trials Register May-02 - 2011). Results: The radiograph measurements showed very high intra-and interrater agreement. The intra- class correlation (ICC) of the intrarater agreement was 0.97 for rater 1 and 0.98 for rater 2. The intrarater reliability was 0.99 using the mean values of both rater measurements. The mean difference between the average radiograph measurement and the 3D-CT-based measurement was 0.41 degrees (SD 11.24 degrees) (range: -33.85 degrees-22.50 degrees; 95 % limits of agreement: - 21.63 - 22.45), but there was no correlation found between both methods. Conclusion: Measuring stem version with the help of commercially available digital planning software on plain radiographs after THA has high intra- and interrater reliability but clinically inacceptable validity and reliability when compared to 3D-CT scans.
引用
收藏
页码:763 / 767
页数:5
相关论文
共 50 条
  • [1] Plain Radiographs Fail to Reflect Femoral Offset in Total Hip Arthroplasty
    Weber, Markus
    Woerner, Michael L.
    Springorum, Hans-Robert
    Hapfelmeier, Alexander
    Grifka, Joachim
    Renkawitz, Tobias F.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (08): : 1661 - 1665
  • [2] Assessment or magnification or digital pelvic radiographs in total hip arthroplasty using templating software
    White, S. P.
    Bainbridge, J.
    Smith, E. J.
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2008, 90 (07) : 592 - 596
  • [3] Assessment of magnification of digital radiographs in total HIP arthroplasty
    Olmedo-Garcia, Nuria I.
    Martinez Vergara, Jose L.
    Aparici Miralles, Tamara L.
    Sanchez Andres, Juan V.
    Mesado Vives, Adela
    Cruz Renovell, Encarna
    Granell Beltran, Vicente
    [J]. JOURNAL OF ORTHOPAEDICS, 2018, 15 (04) : 931 - 934
  • [4] Plain Radiograph Fails to Reflect the Alignment and Advantages of Navigation in Total Knee Arthroplasty
    Choi, Won Chul
    Lee, Sahnghoon
    An, Joon Hwan
    Kim, Dongwook
    Seong, Sang Cheol
    Lee, Myung Chul
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (05): : 756 - 764
  • [5] The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
    Yang Soo Park
    Won Chul Shin
    Sang Min Lee
    Sang Ho Kwak
    Jung Yun Bae
    Kuen Tak Suh
    [J]. Journal of Orthopaedic Surgery and Research, 13
  • [6] The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
    Park, Yang Soo
    Shin, Won Chul
    Lee, Sang Min
    Kwak, Sang Ho
    Bae, Jung Yun
    Suh, Kuen Tak
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [7] The reliability and accuracy of measuring anteversion of the acetabular component on plain anteroposterior and lateral radiographs after total hip arthroplasty
    Shin, W. C.
    Lee, S. M.
    Lee, K. W.
    Cho, H. J.
    Lee, J. S.
    Suh, K. T.
    [J]. BONE & JOINT JOURNAL, 2015, 97B (05): : 611 - 616
  • [8] Digital templating in total hip arthroplasty with the Mayo stem
    Christian Wedemeyer
    Henning Quitmann
    Jie Xu
    Hansjoerg Heep
    Marius von Knoch
    Guido Saxler
    [J]. Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 1023 - 1029
  • [9] Digital templating in total hip arthroplasty with the Mayo stem
    Wedemeyer, Christian
    Quitmann, Henning
    Xu, Jie
    Heep, Hansjoerg
    von Knoch, Marius
    Saxler, Guido
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (10) : 1023 - 1029
  • [10] Validation of mediCAD® software for fully digital preoperative planning of total hip arthroplasty: a retrospective study
    Bouche, Pierre-Alban
    Corsia, Simon
    Auberger, Guillaume
    Descamps, Jules
    Anract, Philippe
    Hamadouche, Moussa
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (06)