The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs

被引:28
|
作者
Park, Yang Soo [1 ]
Shin, Won Chul [1 ]
Lee, Sang Min [1 ]
Kwak, Sang Ho [1 ]
Bae, Jung Yun [1 ]
Suh, Kuen Tak [1 ,2 ]
机构
[1] Pusan Natl Univ, Sch Med, Yangsan Hosp, Dept Orthoped, Yangsan, South Korea
[2] Pusan Natl Univ, Res Inst Convergence Biomed Sci & Technol, Dept Orthoped Surg, Yangsan Hosp,Sch Med, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2018年 / 13卷
关键词
Anteversion; Acetabular component; Plain radiograph; Total hip arthroplasty; MEASURING CUP ORIENTATION; POLYETHYLENE WEAR; ANTEROPOSTERIOR RADIOGRAPHS; INTRACLASS CORRELATIONS; LATERAL RADIOGRAPHS; RELIABILITY; REPLACEMENT; ACCURACY; POSITION; VERSION;
D O I
10.1186/s13018-018-0767-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Several radiological methods for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) exist, and no single standardized method has been established. We evaluated the reliability and accuracy of six widely utilized methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., Ackland et al., and Woo and Morrey) for measuring anteversion on plain radiographs, using a reference standard in the same definition obtained from the PolyWare programme. Methods: We reviewed 71 patients who underwent primary unilateral THA. The anteversion of the acetabular component was measured on pelvis AP radiographs using five different methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., and Ackland et al.) and on cross-table lateral radiographs using the method of Woo and Morrey. The values obtained using the PolyWare programme, which determines the anteversion of the acetabular component by edge detection, were regarded as the reference standard. Results: Intra-and inter-observer reliabilities were excellent for all methods using plain radiographs, including the PolyWare programme. The method of Liaw et al. obtained values similar to those obtained using the PolyWare programme and was thus considered accurate (P = 0.447). However, values obtained using the other five methods significantly differed from those obtained using the PolyWare programme and were thus considered less accurate (P < 0.001, P < 0.001, P < 0.001, P = 0.007, and P < 0.001, respectively). Conclusion: The method of Liaw et al. is more accurate than other methods using plain radiographs for the measurement of the anteversion of the acetabular component after THA, with reference to the anteversion obtained from the PolyWare programme.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
    Yang Soo Park
    Won Chul Shin
    Sang Min Lee
    Sang Ho Kwak
    Jung Yun Bae
    Kuen Tak Suh
    Journal of Orthopaedic Surgery and Research, 13
  • [2] An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs
    Nomura, T.
    Naito, M.
    Nakamura, Y.
    Ida, T.
    Kuroda, D.
    Kobayashi, T.
    Sakamoto, T.
    Seo, H.
    BONE & JOINT JOURNAL, 2014, 96B (05): : 597 - 603
  • [3] The reliability and accuracy of measuring anteversion of the acetabular component on plain anteroposterior and lateral radiographs after total hip arthroplasty
    Shin, W. C.
    Lee, S. M.
    Lee, K. W.
    Cho, H. J.
    Lee, J. S.
    Suh, K. T.
    BONE & JOINT JOURNAL, 2015, 97B (05): : 611 - 616
  • [4] A precise method for determining acetabular component anteversion after total hip arthroplasty
    Murphy, M. P.
    Killen, C. J.
    Ralles, S. J.
    Brown, N. M.
    Hopkinson, W. J.
    Wu, K.
    BONE & JOINT JOURNAL, 2019, 101B (09): : 1042 - 1049
  • [5] A novel method of acetabular component anteversion measurement on plain radiographs
    Xiao, He
    Zheng, Nian-Ye
    Wang, Jian
    Shi, Zhan-Jun
    Chen, Rong
    Wang, Pin-Kai
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [6] Ellipse method for measuring Liaw’s anteversion of the acetabular component after total hip arthroplasty
    Kuei-Lin Yeh
    Tai-Yin Wu
    Hsuan-Hsiao Ma
    Sheng-Mou Hou
    Chen-Kun Liaw
    BMC Musculoskeletal Disorders, 21
  • [7] Ellipse method for measuring Liaw's anteversion of the acetabular component after total hip arthroplasty
    Yeh, Kuei-Lin
    Wu, Tai-Yin
    Ma, Hsuan-Hsiao
    Hou, Sheng-Mou
    Liaw, Chen-Kun
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [8] A Novel Method for Evaluating Combined Component Anteversion in Total Hip Arthroplasty on Cross-Table Lateral Hip Radiographs
    Dimitriou, Dimitris
    Zindel, Christoph
    Winkler, Elin
    Cornaz, Frederic
    Mazel, Peter
    Zingg, Patrick
    SWISS MEDICAL WEEKLY, 2023, 153 : 43S - 44S
  • [9] A novel method for evaluating combined component anteversion in total hip arthroplasty on cross-table lateral hip radiographs
    Dimitris Dimitriou
    Christoph Zindel
    Elin Winkler
    Frédéric Cornaz
    Peter Mazel
    Patrick O. Zingg
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 5977 - 5984
  • [10] A novel method for evaluating combined component anteversion in total hip arthroplasty on cross-table lateral hip radiographs
    Dimitriou, Dimitris
    Zindel, Christoph
    Winkler, Elin
    Cornaz, Frederic
    Mazel, Peter
    Zingg, Patrick O. O.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (09) : 5977 - 5984