A precise method for determining acetabular component anteversion after total hip arthroplasty

被引:15
|
作者
Murphy, M. P. [1 ]
Killen, C. J. [1 ]
Ralles, S. J. [1 ]
Brown, N. M. [1 ]
Hopkinson, W. J. [1 ]
Wu, K. [1 ]
机构
[1] Loyola Univ, Med Ctr, Dept Orthopaed Surg & Rehabil, 2160 S 1st Ave, Maywood, IL 60153 USA
来源
BONE & JOINT JOURNAL | 2019年 / 101B卷 / 09期
关键词
MEASURING CUP ORIENTATION; PLAIN ANTEROPOSTERIOR; CT METHOD; RELIABILITY; POSITION; RADIOGRAPHS; NAVIGATION; ACCURACY; SYSTEM; DISLOCATIONS;
D O I
10.1302/0301-620X.101B9.BJJ-2019-0085.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims Several radiological methods of measuring anteversion of the acetabular component after total hip arthroplasty (THA) have been described. These are limited by low reproducibility, are less accurate than CT 3D reconstruction, and are cumbersome to use. These methods also partly rely on the identification of obscured radiological borders of the component. We propose two novel methods, the Area and Orthogonal methods, which have been designed to maximize use of readily identifiable points while maintaining the same trigonometric principles. Materials and Methods A retrospective study of plain radiographs was conducted on 160 hips of 141 patients who had undergone primary THA. We compared the reliability and accuracy of the Area and Orthogonal methods with two of the current leading methods: those of Widmer and Lewinnek, respectively. Results The 160 anteroposterior pelvis films revealed that the proposed Area method was statistically different from those described by Widmer and Lewinnek (p < 0.001 and p = 0.004, respectively). They gave the highest inter- and intraobserver reliability (0.992 and 0.998, respectively), and took less time (27.50 seconds (SD 3.19); p < 0.001) to complete. In addition, 21 available CT 3D reconstructions revealed the Area method achieved the highest Pearson's correlation coefficient (r = 0.956; p < 0.001) and least statistical difference (p = 0.704) from CT with a mean within 1 degrees of CT-3D reconstruction between ranges of 1 degrees to 30 degrees of measured radiological anteversion. Conclusion Our results support the proposed Area method to be the most reliable, accurate, and speedy. They did not support any statistical superiority of the proposed Orthogonal method to that of the Widmer or Lewinnek method.
引用
收藏
页码:1042 / 1049
页数:8
相关论文
共 50 条
  • [1] Ellipse method for measuring Liaw’s anteversion of the acetabular component after total hip arthroplasty
    Kuei-Lin Yeh
    Tai-Yin Wu
    Hsuan-Hsiao Ma
    Sheng-Mou Hou
    Chen-Kun Liaw
    BMC Musculoskeletal Disorders, 21
  • [2] Ellipse method for measuring Liaw's anteversion of the acetabular component after total hip arthroplasty
    Yeh, Kuei-Lin
    Wu, Tai-Yin
    Ma, Hsuan-Hsiao
    Hou, Sheng-Mou
    Liaw, Chen-Kun
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [3] The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
    Yang Soo Park
    Won Chul Shin
    Sang Min Lee
    Sang Ho Kwak
    Jung Yun Bae
    Kuen Tak Suh
    Journal of Orthopaedic Surgery and Research, 13
  • [4] The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
    Park, Yang Soo
    Shin, Won Chul
    Lee, Sang Min
    Kwak, Sang Ho
    Bae, Jung Yun
    Suh, Kuen Tak
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [5] Anteversion of the Acetabular Component Aligned With the Transverse Acetabular Ligament in Total Hip Arthroplasty
    Miyoshi, Hideaki
    Mikami, Hiroshi
    Oba, Koichi
    Amari, Rui
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 916 - 922
  • [6] A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty
    Aydogan M.
    Burç H.
    Saka G.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 897 - 903
  • [7] Effect of acetabular component anteversion on dislocation mechanisms in total hip arthroplasty
    Higa, Masaru
    Tanino, Hiromasa
    Abo, Masayoshi
    Kakunai, Satoshi
    Banks, Scott A.
    JOURNAL OF BIOMECHANICS, 2011, 44 (09) : 1810 - 1813
  • [8] Use of a sentinel pin as a guide to acetabular component anteversion in total hip arthroplasty
    Goldstein, Wayne M.
    Jimenez, Matthew L.
    Gordon, Alexander C.
    Branson, Jill Jasperson
    Berland, Kimberly
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A : 97 - 100
  • [9] Influence of sagittal degenerative spondylolisthesis on anteversion of the acetabular component in total hip arthroplasty
    Shen, Kaiwei
    Lin, Liqiong
    Feng, Eryou
    Zhang, Yiyuan
    Xiao, Lili
    Lin, Feitai
    Li, Zhanglai
    ORTHOPADE, 2021, 50 (08): : 664 - 673
  • [10] The influence of sagittal spinal deformity on anteversion of the acetabular component in total hip arthroplasty
    Phan, D.
    Bederman, S. S.
    Schwarzkopf, R.
    BONE & JOINT JOURNAL, 2015, 97B (08): : 1017 - 1023