Plain Radiographs Fail to Reflect Femoral Offset in Total Hip Arthroplasty

被引:39
|
作者
Weber, Markus [1 ]
Woerner, Michael L. [1 ]
Springorum, Hans-Robert [1 ]
Hapfelmeier, Alexander [2 ]
Grifka, Joachim [1 ]
Renkawitz, Tobias F. [1 ]
机构
[1] Univ Regensburg, Med Ctr, Dept Orthoped Surg, D-93053 Regensburg, Germany
[2] Tech Univ Munich, Inst Med Stat & Epidemiol, D-80290 Munich, Germany
来源
JOURNAL OF ARTHROPLASTY | 2014年 / 29卷 / 08期
关键词
leg length; global offset; femoral offset; total hip arthroplasty; radiography; accuracy; LIMB-LENGTH DISCREPANCY; LEG-LENGTH; INEQUALITY; RELIABILITY; OSTEOARTHRITIS; REPLACEMENT;
D O I
10.1016/j.arth.2014.03.023
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Successful biomechanical reconstruction is a major goal in total hip arthroplasty (THA). We measured leg length (LL), global (GO) and femoral offset (FO) change on anteroposterior pelvis radiographs and on three-dimensional computed-tomography (3D-CT) with fiducial landmarks after cementless THA on 18 hips of cadaveric specimens. Measurements on radiographs were performed twice by four examiners and showed high interobserver (mean CCC >= 0.79) and intraobserver agreements (mean ICC >= 0.88). Mean differences between radiographic and 3D-CT measurements were 1.0 (SD 2.0) mm for LL, 0.6 (SD 3.6) mm for GO and 1.4 (SD 5.2) mm for FO. 1% of radiographic LL-, 15% of GO-and 35% of FO measurements were outside a tolerance limit of 5 mm. Radiographs seem acceptable for measuring LL/GO change but fail to reflect FO change in THA. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1661 / 1665
页数:5
相关论文
共 50 条
  • [1] The influence of hip rotation on femoral offset in plain radiographs
    Lechler, Philipp
    Frink, Michael
    Gulati, Aashish
    Murray, David
    Renkawitz, Tobias
    Buecking, Benjamin
    Ruchholtz, Steffen
    Boese, Christoph Kolja
    [J]. ACTA ORTHOPAEDICA, 2014, 85 (04) : 389 - 395
  • [2] Digital Planning Software Fails to Reflect Stem Torsion on Plain Radiographs after Total Hip Arthroplasty
    Worlicek, M.
    Weber, M.
    Zeman, F.
    Woerner, M.
    Schneider, M.
    Grifka, J.
    Renkawitz, T.
    Craiovan, B.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (08): : 763 - 767
  • [3] An intraoperative device to restore femoral offset in total hip arthroplasty
    Enxing Xue
    Zhen Su
    Chengwang Chen
    Paul Kim Chiu Wong
    Hong Wen
    Yu Zhang
    [J]. Journal of Orthopaedic Surgery and Research, 9
  • [4] Intraoperative Measurement of Femoral Offset in Primary Total Hip Arthroplasty
    Iqbal, Shoaib
    Datir, Sandeep
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2015, 30 (04) : E15 - E16
  • [5] Changes of center of rotation and femoral offset in total hip arthroplasty
    Bjarnason, Jon A.
    Reikeras, Olav
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2015, 3 (22)
  • [6] Effect of femoral offset on the gait after total hip arthroplasty
    邬培慧
    [J]. 外科研究与新技术, 2011, 20 (02) : 116 - 116
  • [7] An intraoperative device to restore femoral offset in total hip arthroplasty
    Xue, Enxing
    Su, Zhen
    Chen, Chengwang
    Wong, Paul Kim Chiu
    Wen, Hong
    Zhang, Yu
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9
  • [8] The role of femoral offset and abductor lever arm in total hip arthroplasty
    Bjørdal F.
    Bjørgul K.
    [J]. Journal of Orthopaedics and Traumatology, 2015, 16 (4) : 325 - 330
  • [9] The association of postoperative global femoral offset with total hip arthroplasty outcomes
    Yuki Hirano
    Norio Imai
    Asami Nozaki
    Yoji Horigome
    Hayato Suzuki
    Hiroyuki Kawashima
    [J]. Scientific Reports, 13
  • [10] Effect of Femoral Offset on Pain and Function After Total Hip Arthroplasty
    Cassidy, Kevin A.
    Noticewala, Manish S.
    Macaulay, William
    Lee, Jonathan H.
    Geller, Jeffrey A.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (10): : 1863 - 1869